The setup is an add-on 4th/5th axis with its own drives and its own controller. On its parameter screen, each parameter shows eight positions. The manual says PCN (parameter No. 2, bit 4) can be0, 1, 2 or 3. When you try to key in a 2, the panel appears to accept only 0 or 1. The controller is fine. Those positions are not bits.
First check: confirm which parameter number and which column the cursor is on before you type anything. Most failed entries on this controller come from writing into the wrong position or the wrong parameter.
These parameters live in the axis controller, not in the Fanuc. The CNC parameter screen will never show PCN, CLPP or JPC. You edit them on the TPC-Jr panel with the machine stopped.
Skip the fixes that waste time on a digit-field parameter
These are the usual responses to a manual that lists values 0 to 3 for a single bit. None of them resolves the problem.
-
Leave PCN and NLSC at 0 and move on. The factory default for the parameter is
00000000, so the machine will run. But 0 is one of four selectable behaviors for the P-mode switching level, not a neutral "off". BecauseJPCcan make jog followPCN, you have also fixed the jog behavior without choosing it. -
Treat it as a documentation typo and assume only 0/1 is valid. Parameter 103's recommended setting of
00000002already contradicts that. So does the value 3 called for inCLPP104#1. Many parameters in this manual assign values other than 0 and 1 to a single "bit". - Pack the value as a binary or octal number. Some engineers try summing bit weights, switching the entry to octal, or typing one combined number for the whole parameter. This controller does not decode a packed word. Each position stores its own value.
- Look for a companion BCD parameter that holds the "real" value. None is needed. The value sits in the position itself.
-
Dig through parameters 135 and 136. They hold the timings and forces used in P mode. They do not select the switching level that
PCNcontrols.
Understand why eight "bits" each accept 0-9
The TPC-Jr G Series manual says it directly: data from 0 to 9 is set for each position, b0 through b7. The eight-column bit layout is a display format only. Each column is a single decimal digit cell, not a binary flag.
- A parameter that is a true on/off switch simply uses 0 and 1 in its cell.
- A parameter like
PCNuses the same cell as a small selector: 0, 1, 2 or 3, with each value meaning a different behavior. - Calling the cell a "bit" in the parameter table is misleading. Functionally, each parameter is an array of eight single-digit settings, and each digit is really a nibble or byte.
The manufacturer borrowed the familiar CNC bit-parameter screen layout and packed more options into it. Once you read every column as "digit 0-9", the whole manual makes sense. That includes the other parameters that list non-binary values.
The panel does accept 2 and 3 in the correct position. On this installation, a later attempt wrote the value successfully. The earlier failure came from writing into the wrong segment or the wrong parameter, not from a controller limit.
Match the entry symptom to its cause
| What you see on the panel | Likely cause | What to do |
|---|---|---|
| Typing 2 or 3 is refused; only 0/1 seems to take | Cursor is on a position or parameter that really is binary, or on the wrong parameter number | Re-select the parameter number, count columns from b0, and enter the digit again |
| Value "takes" but machine behavior does not change | Digit written into the neighboring column, e.g. b3 or b5 instead of b4 | Read back the full 8-digit string and compare it with your planned string |
| Another function changed after the edit | An existing non-zero digit was overwritten while retyping the whole parameter | Restore it from your recorded original string; edit only the target column |
| Parameter screen will not accept any change | Machine is running, or parameter write is not enabled on the controller | Stop the machine and apply the write-enable condition the controller manual specifies |
| Jog behaves differently after changing PCN |
JPC is set so jog follows PCN
|
Expected behavior; set JPC to disable it if jog must stay independent |
| Searching the Fanuc parameter screen for PCN finds nothing | Parameter belongs to the axis controller, not the CNC | Edit on the axis controller's own panel |
Map the recommended strings to digit positions
Before you type anything, write out the full target string. The layout below assumes the usual CNC convention: b7 is the leftmost column and b0 is the rightmost. Confirm this against the column header in the manual's parameter table.
The recommended setting for parameter 103, 00000002, reads cleanly under that convention: b0 = 2.
Position: b7 b6 b5 b4 b3 b2 b1 b0
No. 103: 0 0 0 0 0 0 0 2 recommended setting, b0 = 2
No. 104: x x x x x x 3 x CLPP (104#1) = 3
No. 2: x x x n x x x x PCN (2#4) = n, where n = 0..3
x = keep whatever digit is already there
-
Parameter 104,
CLPPat #1: the 3 goes in the second column from the right. If the rest of 104 is still at default zeros, the string becomes00000030. -
Parameter 2,
PCNat #4: the value goes in the fifth column from the right. With the rest at default, PCN = 2 reads00020000. -
Other columns in 2 and 104: these carry other functions, including
NLSCandJPC, depending on the parameter. Never assume they are zero. Read them first.
Enter a multi-value digit on the axis controller panel
- Stop the machine and bring the rotary axis to rest. The failed entry on this installation happened while the machine was running; the successful one happened after it stopped.
- Record the current full 8-digit string for parameters 2, 103, 104, 135 and 136. This is your rollback.
- Enable parameter writing using whatever method the TPC-Jr G Series manual specifies for your unit, such as a key, mode or protect setting.
- Select the parameter number. Check the number on screen before you move the cursor. Landing on an adjacent parameter is the most common reason an entry "won't take".
- Move the cursor to the target column, counting from b0 on the right. Count it twice.
- Key in the single digit (for example
3forCLPP) and press the controller's input key. - Read back the whole 8-digit string. Only the target column should have changed.
- Check the parameter table for any note saying the setting takes effect only after power-off. If it has one, cycle the axis controller before testing.
- Disable parameter writing again.
If a digit above 1 is still refused in a column where the manual lists values 0-3, go back to step 4. You are almost certainly in the wrong parameter.
Decide PCN, JPC, NLSC and 135/136 together
These settings are coupled. Changing one without the others gives motion that looks wrong even though every value was entered correctly.
| Setting | Where | What it controls | Decision |
|---|---|---|---|
PCN |
No. 2, #4 | Level setting used when switching into P mode; values 0-3 | Pick the value from the PCN notes in the parameter table; default is 0 |
JPC |
Per parameter table | Jog operation either follows PCN or is disabled |
Decide whether jog should mirror the PCN behavior |
NLSC |
Per parameter table | Listed alongside PCN in the same setting group |
Default 0; change only per the manual's notes for your P-mode choice |
| Parameters 135 / 136 | No. 135, 136 | Timings and forces applied in P mode | Set these after choosing PCN; they tune the behavior PCN selects |
CLPP |
No. 104, #1 | Digit-valued setting; manual calls for 3 | Enter 3 in the b1 column |
| No. 103 | No. 103 | Recommended 00000002
|
Enter 2 in the b0 column |
Work in this order:
- Choose the
PCNvalue from the manual's notes for the P-mode switching level. - Set 135/136 to the timings and forces that suit that level.
- Choose
JPC. - Leave
NLSCat default unless the notes tie it to your PCN choice.
Confirm the setting took and the axis behaves on the Fanuc side
A correct read-back on the panel is only half the check. Timing changes on the axis side show up on the Fanuc as late or missing completion signals.
- Read-back: compare every changed parameter against the planned string, and every unchanged one against your recorded originals.
- Power cycle: if any edited parameter is marked as effective after power-off, cycle the controller and read back again. This confirms the value was stored and not just displayed.
-
Jog test: jog the axis at low speed. If
JPCfollowsPCN, the jog should show the new P-mode behavior. IfJPCis disabled, jog should be unchanged. -
Handshake timing: on the Fanuc side, watch whether the finish/complete signal from the axis controller now arrives later. If it does, the CNC may wait or alarm. Correct this with 135/136, not with
PCN. - Record: log the final 8-digit strings next to the originals so the next technician does not have to decode the columns again.
FAQ
Why does the TPC-Jr manual list values 0-3 for a single bit like PCN?
Each position b0-b7 is a decimal digit cell that accepts 0-9, not a binary bit. The bit layout is only the display format, so PCN at parameter 2 #4 is a four-way selector for the P-mode switching level.
Why does the controller reject 2 or 3 when I type it into a parameter bit?
The cursor is usually on the wrong parameter or the wrong column, often one that really is binary. Stop the machine, re-select the parameter number, count columns from b0 on the right, and enter the digit again.
How do I set CLPP 104#1 to 3?
Select parameter 104, move to the b1 column (second from the right), and enter 3. With the other columns at default, the string reads 00000030.
Why does parameter 103 recommend 00000002 if the fields are bits?
Because the fields are digit cells. 00000002 means the b0 column holds the value 2, which is only possible because each position stores 0-9.
Why does the value still get refused after checking the column and stopping the machine?
At that point, stop experimenting with entry methods. Record the parameter number, column, the value you tried, the full 8-digit read-back, and the manual revision. Then contact the rotary axis controller manufacturer's official support with those details, since write protection or a firmware-specific restriction on that parameter can only be confirmed by them.