Downloading S7-PLCSIM V15.1 Update 1: Complete Install Guide
S7-PLCSIM V15.1 Update 1 is the simulation runtime that mirrors the behavior of S7-1200, S7-1500, ET 200SP, ET 200pro, and the S7-1500 Software Controller inside a TIA Portal V15.1 engineering station. The Update 1 package is classified by Siemens as export-restricted software, which is why the download is gated behind a manual approval workflow on the Siemens Industry Online Support portal. This reference explains the end-to-end process: confirming system requirements, completing the export-restricted registration, retrieving the installer packages from the CAx download manager, installing the base V15.1 release followed by Update 1, and verifying the integrated simulation environment inside TIA Portal.
1. Overview of S7-PLCSIM V15.1 and Update 1
S7-PLCSIM is the standard Siemens PLC simulator for the SIMATIC S7-1200 and S7-1500 controller families. It allows engineers to download, test, and debug STEP 7 programs on a software instance of the controller without requiring physical hardware. The V15.1 release is the component branch that ships with TIA Portal V15.1 (Engineering Framework) and supports the same CPU firmware targets (FW V2.x for S7-1200 and FW V2.5 / V2.6 for S7-1500) that TIA Portal V15.1 generates.
Update 1 (V15.1 Upd1) is a maintenance release that patches defects and adds minor functional improvements. It must be installed on top of the V15.1 base package. You cannot install Upd1 on a clean machine that does not already have the V15.1 base product installed.
| Package | Siemens Entry ID | Distribution | License |
|---|---|---|---|
| S7-PLCSIM V15.1 (base) | 109761045 | Siemens Industry Online Support (SIOS) | Trial (21 days) / Floating license |
| S7-PLCSIM V15.1 Update 1 | 109764220 | Siemens Industry Online Support (CAx download manager) | Floating license (extends trial) |
The Updates article is published in the SIOS entry Updates for PLCSIM V15.1 (ID 109764220) and explicitly notes that the software is no longer actively maintained. Despite the maintenance status, the package remains the only sanctioned path to a TIA Portal V15.1 simulation environment.
2. Prerequisites
Before you can install S7-PLCSIM V15.1 Update 1, your engineering workstation must satisfy the following requirements. Failing any of these conditions either blocks the installation or produces silent failures during TIA Portal integration.
2.1 Operating System
- Windows 7 SP1 (64-bit, Professional / Enterprise / Ultimate)
- Windows 10 (64-bit, version 1607 or later, Professional / Enterprise)
- Windows Server 2012 R2 (64-bit) Std / Datacenter
- Windows Server 2016 (64-bit) Std / Datacenter
2.2 TIA Portal V15.1 Base Installation
S7-PLCSIM V15.1 is a sub-component of the TIA Portal V15.1 framework. The TIA Portal Setup must already be installed and registered, because PLCSIM registers as an add-in against the TIA Portal installation root. If TIA Portal V15.1 Update 1+ is installed, the PLCSIM Add-In is automatically enabled during PLCSIM install.
2.3 Hardware Requirements
| Resource | Minimum | Recommended |
|---|---|---|
| CPU | Intel Core i5-6440EQ (or equivalent) | Intel Core i7 / Xeon E3 or better |
| RAM | 16 GB | 32 GB (large S7-1500 projects) |
| Free Disk Space | 20 GB (TIA + PLCSIM) | 50 GB SSD |
| Display | 1920 x 1080 | 1920 x 1080 with HiDPI scaling |
| Network | Ethernet 1 Gbps | Ethernet 1 Gbps + isolated test VLAN |
2.4 User Account Privileges
Local administrator rights are required to run the Setup.exe launcher. S7-PLCSIM installs:
- Automation License Manager service (if not already present)
- S7-PLCSIM virtual Ethernet adapter driver
- PLCSIM OPC UA server service
2.5 Siemens Industry Online Support Account
An active SIOS account is mandatory. Export-restricted software is gated behind an additional manual approval workflow that can take 2 weeks to 3 months. You must register for the "Extended Registration for Export-Restricted Software" and wait for an email from Siemens confirming that your profile is unlocked.
3. Registering for Export-Restricted Software Download
The most common cause of "I cannot download the package" reports is missing export-restricted approval. Standard SIOS accounts can browse all public articles, but the actual download of the Upd1 executable is intercepted by an additional authentication step.
3.1 Create or Verify Your SIOS Account
- Open the Siemens Industry Online Support portal.
- Click Register in the top-right and provide a corporate email address. Use a domain you control - public webmail addresses (gmail, hotmail, yahoo) are sometimes flagged during manual review.
- Confirm the registration through the verification email sent within minutes of submission.
3.2 Enable the Extended Registration
- Sign in and open My Profile > Account > Extended Registration.
- Select the checkbox I would like to register for the download of export-restricted software.
- Provide all required company data (name, address, country, intended use). The end-use statement is reviewed by Siemens export compliance.
- Submit the request and wait for the approval email. There is no fixed SLA; documented cases range from a few business days to several months depending on country of registration.
3.3 Verify Approval Before Downloading
When your profile is approved, the download buttons for export-restricted articles will become active. If the button still says Login / Register even after logging in, your approval is not yet active. Logging out, restarting the browser, and clearing cookies is the fastest reset.
4. Downloading the S7-PLCSIM V15.1 Base Package
The base S7-PLCSIM V15.1 package is distributed as a trial through SIOS entry ID 109761045. The trial license activates for 21 days, after which a floating license (transferred from an Automation License Manager server) is required.
- Navigate to the SIOS article for S7-PLCSIM V15.1 base (search PLCSIM V15.1 in SIOS; the trial package is normally visible at ID 109761045).
- Click Download and choose a delivery channel:
- Direct download - a single executable (.exe) launcher
- CAx Download Manager - splits the package into smaller parts and supports resume; recommended for large downloads
- If using the CAx Download Manager, install the manager, log in with your SIOS account, paste the article number, and add the package to the download queue.
- Save the package to a working directory with at least 8 GB free, for example
D:\Siemens\Installers\PLCSIM_V15_1\. - Verify the SHA-1 / SHA-256 hash published in the article if listed; mismatched hashes indicate a corrupted transfer.
5. Downloading the Update 1 Package
The Update 1 package is published in SIOS article Updates for PLCSIM V15.1 (ID 109764220). Unlike the base package, Upd1 is not available as a trial - it requires an existing floating license or a customer-licensed seat.
- Open the SIOS article 109764220 directly.
- Confirm the Extended Registration indicator is green on your profile. If it is not, the download button is disabled and the request will fail with an authentication error.
- Click Download. The article will route you to the CAx Download Manager (the same manager used for the base package).
- Add the Upd1 package to the queue and download it to the same working directory used for the base package.
6. Installation Sequence
The installation order is critical. PLCSIM Upd1 cannot be installed on a workstation that does not already host the V15.1 base product. Reversing the order produces an immediate rollback with error code 0x80004005 (E_FAIL) in the Setup log.
6.1 Install the Base Package
- Right-click the PLCSIM_V15_1.exe launcher and select Run as administrator.
- Select Install and accept the license terms.
- Choose the installation path. The default is
C:\Program Files\Siemens\Automation\PLCSIM\V15.1\. - When prompted, select the components:
- S7-PLCSIM V15.1
- PLCSIM OPC UA Server (required for OPC UA connections from external HMI/SCADA)
- Documentation (PDF manuals)
- Wait for the Setup to complete. A typical install takes 10 - 20 minutes on an SSD.
- Do not restart immediately if prompted. Reboot only when the installer returns the Restart required dialog.
6.2 Verify the Base Install
Before installing Upd1, confirm the base package is registered correctly.
- Open TIA Portal V15.1.
- Create or open any project that contains an S7-1500 CPU.
- Click Start Simulation in the toolbar. The PLCSIM launcher should appear with a green PLCSIM ready indicator.
- If Start Simulation is greyed out, open Help > Installed Software and confirm S7-PLCSIM V15.1 is listed. A missing entry indicates a silent installation failure - check the Setup log in
%TEMP%\Siemens\SetupLogs.
6.3 Install Update 1
- Right-click the PLCSIM_V15_1_Upd1.exe launcher and select Run as administrator.
- Accept the license terms.
- The installer detects the existing V15.1 base install and offers an Update path. Confirm.
- Wait for the Setup to complete. Upd1 typically installs in 5 - 10 minutes.
- Reboot the workstation when prompted. A clean boot is required for the PLCSIM virtual network driver to bind correctly.
7. Verifying the Integrated Installation
After the workstation has rebooted, run a full integration check to confirm that PLCSIM V15.1 Update 1 is operational inside TIA Portal.
7.1 Software Inventory
Open TIA Portal V15.1 > Help > Installed Software and verify the following entries are present:
| Component | Expected Version | Source |
|---|---|---|
| S7-PLCSIM | V15.1 Update 1 (Build number per SIOS release notes) | SIOS 109764220 |
| STEP 7 Professional | V15.1 Update 1 (or higher) | TIA Portal installer |
| Automation License Manager | V6.0 SP7 or later | Bundled with TIA |
7.2 Live Simulation Test
- In TIA Portal V15.1, open an existing project with an S7-1500 CPU (or create a new one and add an S7-1500 CPU such as 6ES7511-1AK02-0AB0).
- Compile the hardware configuration (HW > Compile) and the software blocks (PLC > Compile).
- Click Start Simulation in the toolbar.
- Wait for the PLCSIM instance window to open. Confirm:
- The RUN LED is green
- The MAINT LED is off
- The ERROR LED is off
- Download the project to the simulated PLC (Online > Download to Device).
- Toggle an input bit in the PLCSIM instance. Verify the corresponding output updates in the project online view.
7.3 Watch Table / Trace Test
- Open a watch table and force a tag. PLCSIM must accept the force.
- Open the Traces editor, configure a 1-second trace on a real tag, and start the recording. PLCSIM should return sample points.
7.4 OPC UA Connectivity Test (Optional)
If the OPC UA server component was installed, open a UA client (UaExpert is the canonical test client) and connect to opc.tcp://<plcsim-host>:4840. A successful browse of the server namespace confirms the OPC UA stack is operational.
8. Cross-Platform Notes: VMware and Physical Hosts
A common scenario - and one that motivates this entire workflow - is migrating a TIA Portal project from a virtualized Windows 7 engineering environment to a physical Windows 10 host. Several constraints apply when PLCSIM is the target.
8.1 TIA Portal V15.1 on Windows 10
Windows 10 (build 1607 or later) is a supported target for TIA Portal V15.1. The combination of physical Windows 10 + TIA Portal V15.1 + PLCSIM V15.1 Update 1 is the standard, fully supported deployment topology for new engineering seats.
8.2 TIA Portal V15.1 Inside a Windows 7 VM
TIA Portal V15.1 runs on Windows 7 SP1 (64-bit). However, the PLCSIM virtual network adapter driver depends on the Windows Filtering Platform and may produce transient errors under heavy VM host CPU oversubscription. Best practice when consolidating to a physical Windows 10 host:
- Archive the TIA Portal V15.1 project on the VM (Project > Archive).
- Transfer the archive to the physical Windows 10 host.
- Retrieve the archive (Project > Retrieve).
- Re-compile the hardware configuration against the new installation - some device catalog revisions differ between the VM image and a fresh physical install.
- Download into PLCSIM V15.1 Update 1 and validate the test sequence.
9. Troubleshooting Matrix
| Symptom | Likely Root Cause | Resolution |
|---|---|---|
| Download button is greyed out / Login required loop | Export-restricted registration not yet approved | Verify approval email has been received; re-enable the checkbox under Extended Registration |
| Setup rolls back immediately with 0x80004005 | Update 1 installed before base package, or base package missing | Uninstall, install base V15.1, then re-run Upd1 |
| "PLCSIM not installed" error inside TIA Portal | Silent install failure or pre-V15.1 TIA Portal detected | Check TIA Portal Help > Installed Software; verify build number >= V15.1 |
| Virtual network adapter fails to bind | Hyper-V virtual switch conflict or VPN client binding | Disable conflicting virtual adapters; reboot; if on VM, use bridged NIC mode |
| Start Simulation is greyed out | Project does not contain a supported CPU | Add an S7-1200 (FW 4.x), S7-1500, ET 200 CPU, or S7-1500 Software Controller to the project |
| Download to PLCSIM fails with "Online connection not established" | PLCSIM instance not started, or PG/PC interface set to a real NIC | Start PLCSIM first; set PG/PC interface to PLCSIM Virtual Ethernet Adapter |
| Force commands are not applied | Force job blocked by access level configured in the CPU security settings | Open CPU properties > Protection > adjust access level to "Full access incl. fail-safe" or supply the correct password |
| OPC UA server returns Bad_ConnectionRefused | OPC UA server component not selected during install, or Windows Firewall blocking TCP/4840 | Modify Setup and add PLCSIM OPC UA Server; create an inbound firewall rule for TCP/4840 |
10. Frequently Asked Questions
How long does the Siemens export-restricted approval take?
The Siemens export compliance team typically responds within 2 weeks to 3 months depending on country of registration and the corporate end-use statement. If the approval email does not arrive after two months, disable and re-enable the Extended Registration checkbox under your SIOS profile and confirm the registered email address is spelled correctly.
Can I install S7-PLCSIM V15.1 Update 1 without the base package?
No. Update 1 is a delta install that targets the V15.1 base product. Installing Upd1 on a workstation that does not already host the V15.1 base package causes the Setup to roll back with error 0x80004005. Install the base package first, verify it inside TIA Portal, and only then install Upd1.
Is S7-PLCSIM V15.1 still supported by Siemens?
No. The SIOS article 109764220 explicitly states that S7-PLCSIM V15.1 is no longer maintained. The package is still available for download for users who need to maintain a TIA Portal V15.1 environment, but no further patches will be released.
Which CPUs can I simulate with S7-PLCSIM V15.1 Update 1?
PLCSIM V15.1 supports S7-1200 (FW 4.x), S7-1500 (all firmware variants available in TIA Portal V15.1), ET 200SP CPUs, ET 200pro CPUs, and the S7-1500 Software Controller. S7-300 / S7-400 CPUs are not supported in V15.1 - those targets require STEP 7 V5.x with optional S7-PLCSIM V5.x.
Can I run PLCSIM V15.1 on a virtualized Windows host?
Yes for TIA Portal V15.1 itself, but the PLCSIM virtual network adapter and OPC UA server can produce transient errors when the VM host is CPU-oversubscribed. For predictable behavior, especially when you also need to interact with PLCSIM from external OPC UA clients or HMI panels, prefer a physical engineering workstation.