Fix TIA Portal V18 Set PG/PC Interface Missing in Control Panel

David Krause9 min read
SiemensTIA PortalTroubleshooting
Licensed PE Working through this on a live machine? A Maine-licensed engineer can take it from here — included with IMD hardware, by the hour for everything else. Book an engineer

Fix TIA Portal V18 Set PG/PC Interface Missing in Windows Control Panel

After installing TIA Portal V18 (or V18 Update x) on a Windows 10/11 engineering workstation, the legacy Set PG/PC Interface applet sometimes fails to register as a Control Panel item. The executable still exists under Siemens Automation in the Start menu, but the only network adapter it lists is a generic picture with <none> next to it, and no interface can be selected, added, or assigned to an online access point. This article documents the root cause, the recommended Siemens-supplied fix (PC_Identifier), and the surrounding configuration steps needed to get a CP (PROFINET/Industrial Ethernet) interface online again.

Field impact: Without a working PG/PC interface assignment, TIA Portal cannot establish an online connection to any SIMATIC S7-1200/1500, ET 200, or SINAMICS drive. The project compiles, but Go online, Download to device, and Accessible nodes all return empty lists or Online: Connection failed errors.

1. Problem Summary

Attribute Observed Value
Software STEP 7 / TIA Portal V18 (Basic, Professional, PLCSIM optional)
Operating System Windows 10 (21H2, 22H2) and Windows 11 (21H2, 22H2, 23H2)
Symptom 1 Set PG/PC Interface icon absent from Control Panel > All Control Panel Items
Symptom 2 Shortcut exists under Start > All Apps > Siemens Automation > Set PG/PC Interface
Symptom 3 Opened dialog lists a single network card with <none> and a yellow indicator
Symptom 4 No TCP/IP, PROFINET, or soft-PLC interface available for selection
Symptom 5 TIA Portal Online > Accessible nodes returns no devices

2. Root Cause Analysis

The Set PG/PC Interface tool is a Win32 Control Panel applet (CPL) registered during TIA Portal / STEP 7 setup. It depends on two registry-controlled artifacts:

  1. Registrable CPL file — Siemens.TIA.PGPCInterfaceCPL.cpl or the legacy s7epaepaaxx.cpl, registered under HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows\CurrentVersion\Control Panel\CPLs.
  2. PC station configuration data — the PC_Identifier registry hive that maps installed Siemens PC modules (e.g. CP 1616, CP 1626, CP 1628, Softnet, S7DOS) to logical PC interface names such as S7ONLINE and IE PG/PC interface.

If the PC_Identifier hive is missing, corrupted, or was never created (typical on a clean Windows 11 image where the installer ran with a stripped-down user profile, or after a partial uninstall/reinstall), the applet starts but has no PC station data to populate. The visual placeholder card with <none> is the result.

Why Windows 11 is over-represented: Default user-account-control (UAC) virtualisation, controlled-folder access, and the per-user %LOCALAPPDATA% redirection introduced in Windows 10 1903 and tightened in Windows 11 can cause the TIA installer to write the CPL under the invoking user but not the PC_Identifier hive under HKLM\SOFTWARE\Siemens\Automation. Re-installing TIA does not always re-create the missing hive.

3. Affected Versions and Environment

Component Versions / Models Confirmed Affected
TIA Portal V18, V18 Update 1 through Update 5
STEP 7 (legacy coexistence) V5.6 SP2 / V5.7 when used alongside V18
SIMATIC PC modules CP 1612, CP 1616, CP 1623, CP 1626, CP 1628, Softnet-S7 Lean/Standard, S7-1613/1623 Softnet
CPU families (online target) S7-1200 (V4.x), S7-1500 (V2.x/3.x), ET 200SP/MP, SINAMICS S120/G120
OS builds Windows 10 21H2, 22H2; Windows 11 21H2, 22H2, 23H2, 24H2
Hypervisor (if virtualised) VMWare Workstation 17.x, Hyper-V Gen2 with synthetic NIC passthrough

4. Solution Overview — Install PC_Identifier

Siemens ships a stand-alone repair tool called PC_Identifier that re-creates the missing PC station registry hive and re-registers the Set PG/PC Interface CPL. This is the manufacturer-recommended fix and is documented in Siemens Support Entry 109812676 — "PC Identifier: Information on the function and installation of the PC Identifier".

Why PC_Identifier and not a re-install? A full TIA Portal re-installation (modify/repair) does not always recreate the PC station hive on Windows 11. PC_Identifier is targeted, has no TIA Portal prerequisites, and is safe to run on a live engineering workstation.

5. Step-by-Step Procedure

5.1 Prerequisites

  • Local administrator rights on the workstation.
  • All running TIA Portal instances closed (Siemens.Automation.Portal.exe and S7EPAEX.EXE not running).
  • Approximately 50 MB of free disk space for the unpacked installer.
  • Working internet access to support.industry.siemens.com for the initial download.

5.2 Download PC_Identifier

  1. Open a browser and navigate to https://support.industry.siemens.com/cs/ww/en/view/109812676.
  2. Locate the Downloads table at the bottom of the entry.
  3. Download the file PC_Identifier_Vx_x_x.exe (latest revision is recommended; it is backwards compatible with TIA V14 and newer).
  4. Verify the SHA-256 checksum published on the Siemens entry against the downloaded file using Get-FileHash -Algorithm SHA256 in PowerShell.

5.3 Install PC_Identifier

  1. Right-click the downloaded .exe and choose Run as administrator.
  2. Accept the licence agreement.
  3. Leave the default install path C:\Program Files\Siemens\Automation\PC_Identifier unchanged.
  4. Click Install. The tool creates the registry keys under HKLM\SOFTWARE\Siemens\Automation\PC_Identifier.
  5. Click Finish and reboot the workstation. The reboot is required because the TCP/IP service trigger and Winsock catalog are touched.

5.4 Verify the Set PG/PC Interface CPL

  1. Open Control Panel > All Control Panel Items. The Set PG/PC Interface icon should now be present.
  2. If still missing, manually launch the applet from C:\Program Files\Siemens\Automation\SetPgPcInterface\SetPgPcInterface.cpl (file name varies by version).
  3. Confirm the Interface Parameter Assignment Used field shows at least one entry (e.g. Intel(R) Ethernet Connection I219-LM <TCP/IP>) instead of <none>.

6. Configuring the PG/PC Interface Once Restored

After the applet is functional, the access point that TIA Portal uses by default is S7ONLINE. Configure it as follows:

  1. Open Set PG/PC Interface.
  2. Under Access Point of the Application, select S7ONLINE.
  3. Under Interface Parameter Assignment Used, select the physical or virtual PROFINET/Industrial Ethernet adapter that is wired to the target CPU, e.g.:
    • Intel Ethernet I219-LM <TCP/IP> — for onboard NICs.
    • CP 1616 NDIS <TCP/IP> — for the CP 1616 PC card.
    • Siemens Softnet <TCP/IP> — for the Softnet-S7 software interface.
  4. Click OK and confirm any prompts to take the bus offline momentarily.

Optional entries that are also useful for V18 mixed topologies:

Access Point Use Case Recommended Interface
S7ONLINE Default for S7-1200/1500 online, download, HMI tag routing Realtek/Intel/CP onboard TCP/IP
IE PG/PC interface Legacy STEP 7 V5.x routes & routing tables CP 1616/1623/1626/1628
PROFINET IO RT
PROFINET IO controller (PC station with CP 1628) CP 1628 NDIS
PN/IE Symbian for WinCC Unified (PC RT) online access Any Intel/Realtek onboard

7. Alternative Solutions if PC_Identifier Does Not Resolve It

Run the following in order if the symptom persists after the reboot.

7.1 Re-register the CPL manually

Open an elevated PowerShell and execute:

regsvr32 "C:\Program Files\Siemens\Automation\SetPgPcInterface\s7epaepaaxx.cpl"
regsvr32 "C:\Program Files\Siemens\Automation\SetPgPcInterface\Siemens.TIA.PGPCInterfaceCPL.cpl"

Then re-check the Control Panel.

7.2 Repair TIA Portal V18

Control Panel > Programs and Features > Siemens TIA Portal V18 > Repair. This forces the installer to re-emit the registry keys. A second reboot is required.

7.3 Clear the cached user profile

If the CPL appears for other users but not the current one, delete the cached state under %LOCALAPPDATA%\Siemens\Automation\PGPCInterface and re-launch.

7.4 Firewall / Winsock corruption

TIA Portal installs a Winsock LSP (WinSock Catalog) entry for S7DOS. If a third-party security suite has stripped it, reset the catalog:

netsh winsock reset
netsh int ip reset
ipconfig /flushdns

Reboot after running the commands.

7.5 Clean re-install of the TIA Portal PC station

  1. Uninstall TIA Portal V18 via the Setup installer (not via Programs and Features — the Setup installer also removes the PC station).
  2. Delete the residual folders C:\Program Files\Siemens\Automation and C:\ProgramData\Siemens\Automation.
  3. Run CCleaner or the equivalent registry cleaner only as a last resort (manual deletion of HKLM\SOFTWARE\Siemens\Automation is safer).
  4. Reboot, then re-install TIA Portal V18, then re-install PC_Identifier.

8. Verification & Field Checks

After the fix is in place, run the following checks to confirm the interface is fully functional before returning the workstation to production.

Test Expected Result Tool / Command
Set PG/PC Interface visible in Control Panel Icon appears, double-click launches the dialog Manual check
Network adapter shown in the applet Real NIC name, MAC address visible, no <none> suffix Manual check
Accessible nodes from TIA Portal Target CPU appears with IP and MAC Online → Accessible nodes
Ping the CPU <1 ms on the same subnet, no loss ping 192.168.0.1 -t
Download hardware configuration Successful, online status turns green Project tree → PLC → Download to device
Run diagnostic buffer read Live buffer returned, time stamps current Online & diagnostics → Diagnostic buffer
PLCSIM (if used) connectivity PLCSIM instance shows in Accessible nodes Online → Accessible nodes → PLCSIM tab

9. Common Related Error Codes and Messages

Error / Message Meaning Mitigation
0x011A — The network name cannot be found (WSA error during online) S7ONLINE access point bound to wrong NIC Re-assign S7ONLINE in Set PG/PC Interface
0x80BF — No license for online functions Online licence on USB stick missing or transferred Re-seat licence dongle, restart automation licence manager
0x80C8 — Connection to partner could not be established Sub-net mismatch, firewall blocked TCP/UDP 102, 161/162 (SNMP), 34964 (PN-DCP) Open ports, set CPU and PC in same subnet
0xFFFD — Online: Interface is not assigned Root cause of this article — PC_Identifier missing Install PC_Identifier and reboot
“Set PG/PC Interface is not found in Windows Control Panel” CPL registration missing in registry Re-register CPL, install PC_Identifier
“Accessible nodes returns empty list” No S7ONLINE assignment, no DCP broadcast, wrong VLAN Verify access point, NIC link, DCP multicast (UDP 34964) is allowed

10. Field-Proven Best Practices

  • Always run the TIA Portal V18 setup as a local administrator, not as a domain user with temporary elevation, to avoid UAC virtualisation issues on Windows 11.
  • Pre-install the .NET Framework and Visual C++ runtimes listed in the TIA Portal V18 readme before launching the Setup, especially on freshly imaged Windows 11 24H2 workstations.
  • Capture a baseline of the HKLM\SOFTWARE\Siemens hive with reg export once the system is known-good — invaluable for fast roll-back if a Windows update resets the hive.
  • For laptops that dock/undock, mark the wired adapter as priority in the Set PG/PC Interface dialog and disable the auto-fallback that TIA does on wireless interfaces.
  • Disable PC Sleep and USB selective suspend in the Windows power plan to prevent the CP 1616/1626 from being marked as <none> on resume from sleep.
Safety note: Making the PG/PC interface functional on a plant-floor laptop does not by itself put the field network in a safe state. Always follow the site's Online change request procedure and verify the target CPU's name and IP before issuing a Download to device — STOP or a Reset to factory settings.

11. Frequently Asked Questions

Why does TIA Portal V18's Set PG/PC Interface show only <none> on Windows 11?

The PC station registry hive (PC_Identifier) is missing or corrupted, so the applet cannot enumerate installed Siemens PC modules. Install PC_Identifier from Siemens Support Entry 109812676, reboot, and the network adapters will re-appear with their proper driver names.

Do I have to reinstall TIA Portal V18 to fix the missing Set PG/PC Interface?

No. PC_Identifier is a stand-alone repair tool that re-creates the missing registry keys without touching the TIA Portal installation. It is the manufacturer-recommended first-line fix and is faster than a full repair install.

After installing PC_Identifier, Accessible nodes in TIA Portal is still empty — what next?

Verify the S7ONLINE access point in the Set PG/PC Interface is bound to a working TCP/IP adapter, ping the CPU, allow UDP 34964 (PROFINET DCP) and TCP 102 (ISO-on-TCP) in the Windows firewall, and check that the CPU's PROFINET interface is on the same subnet as the PC.

Will PC_Identifier affect an existing STEP 7 V5.6 / V5.7 installation?

No. PC_Identifier is backwards compatible and only populates the HKLM\SOFTWARE\Siemens\Automation hive. It does not overwrite an existing STEP 7 V5.x PC station configuration. Both TIA Portal V18 and STEP 7 V5.x can coexist afterwards.

Is there a fix that does not require a reboot?

No. The PC_Identifier installer touches the Winsock catalog and the TCP/IP service trigger. A reboot is required for the new PC interface bindings to take effect. Plan the change for a maintenance window.