HMI Template Suite V15.1: Download and Compatibility Reference

David Krause10 min read
HMI / SCADASiemensTechnical Reference
Licensed PE Working through this on a live machine? A Maine-licensed engineer can take it from here — included with IMD hardware, by the hour for everything else. Book an engineer

Overview

The SIMATIC HMI Template Suite is Siemens' reference library of pre-engineered HMI screens, faceplates, scripts, and style assets built on the SIMATIC WinCC Style Guide. Engineers adopt it as a starting point for visualization projects running on Comfort Panels, WinCC Runtime Advanced, and WinCC Runtime Professional, accelerating screen engineering and enforcing a uniform corporate look across machines and lines.

The suite is version-coupled to the corresponding TIA Portal release. Each major TIA Portal release (V14, V15, V15.1, V16, V17, V18, V19) ships with a parallel HMI Template Suite release that must match the project's TIA Portal service pack level. V15.1 is the variant that aligns with TIA Portal V15.1 and is the one commonly requested when older TIA Portal installations remain in production or when customers must maintain machine series already qualified on TIA Portal V15.1.

This reference consolidates the official Siemens channels that still distribute legacy versions of the suite, the version-to-TIA Portal compatibility matrix, the installation prerequisites, and the typical issues encountered when integrating V15.1 templates into an existing WinCC project.

Compatibility rule: Always install the HMI Template Suite whose version index exactly matches the TIA Portal version index used to compile the WinCC project. Mixing the V15.1 template library with TIA Portal V16 or V15 produces unresolved faceplate type conflicts and runtime errors (e.g., 190100 – connection failure, 190500 – faceplate version mismatch).

Version Compatibility Matrix

HMI Template Suite TIA Portal Version WinCC Runtime Target Status (as of TIA V19)
V14 V14 SP1 / V14 Comfort, RT Advanced, RT Professional Legacy – support request only
V15 V15 Comfort, RT Advanced, RT Professional Legacy – support request only
V15.1 V15.1 Comfort, RT Advanced, RT Professional Legacy – distributed via SIOS support request
V16 V16 Comfort, RT Advanced, RT Professional Legacy – support request only
V17 V17 Comfort, RT Advanced, RT Professional Legacy – support request only
V18 V18 Comfort, RT Advanced, RT Professional Available – Siemens Online Support
V19 V19 Comfort, RT Advanced, RT Professional Available – Siemens Online Support

Siemens periodically removes older Template Suite downloads from the public search index once the corresponding TIA Portal version drops below its standard product support lifecycle. V15.1 fell into this category after TIA Portal V16 was released; the download remains available, but only through a direct request to Siemens Technical Support.

Official Download Channels

The first-line distribution channel for every SIMATIC HMI Template Suite version is the Siemens Industry Online Support (SIOS) portal. Each release is published as a separately installable setup (SIMATIC_HMI_Template_Suite_Vxx_x.exe) under entry ID 91174767.

Step-by-step: Locate the HMI Template Suite entry on SIOS

  1. Navigate to the Siemens Industry Online Support portal at support.industry.siemens.com.
  2. Use the search field and enter the article number 91174767 or the phrase HMI Template Suite.
  3. Open the canonical article HMI design with the HMI Template Suite.
  4. Scroll to the Downloads section. Available versions are listed per TIA Portal major release.

When the public download table no longer lists the V15.1 entry (typical once TIA Portal V17 is current), use the Request Support path described below.

Step-by-step: Request a legacy download via Siemens Technical Support

  1. Open the SIOS support landing page at support.industry.siemens.com/cs/ww/en/sc/4868.
  2. Select My Support > Request and authenticate with your Siemens Single Sign-On account (create one if you do not have it – the account is free of charge).
  3. Choose product area SIMATIC HMIHMI SoftwareHMI Template Suite.
  4. In the request text, include: the required version (V15.1), the TIA Portal installation version, the target runtime (Comfort Panel, RT Advanced, RT Professional), the article number 91174767, and the order number / license key if your installation is tied to a SIMATIC HMI license dongle.
  5. Submit the request. Siemens typically delivers a signed download link within 2–5 business days.

Alternative: Sales channel

If a support-account workflow is not feasible, contact your regional Siemens sales representative or authorized SIMATIC HMI distributor. For OEM and end-customer accounts that hold a maintenance contract, the local sales office can provide the V15.1 setup as a file transfer through the Siemens Product Information Management (PIM) portal.

System Prerequisites

Item Requirement
TIA Portal V15.1 (exact match required)
SIMATIC WinCC WinCC V15.1 (Engineering in TIA Portal)
Runtime target SIMATIC Comfort Panels, WinCC Runtime Advanced ≥ V15.1, WinCC Runtime Professional ≥ V15.1
Operating system (engineering) Windows 7 SP1 / Windows 10 (64-bit), language packs matching the project
Disk space ~3.5 GB during installation, ~1.2 GB after
RAM 16 GB minimum recommended for TIA Portal V15.1
.NET .NET Framework 4.6.2 or higher (installed by TIA Portal setup)
Local admin rights Required during installation
Important: Do not install the HMI Template Suite V15.1 on a workstation that hosts a newer TIA Portal (V16, V17, V18, V19) as the primary engineering environment. The V15.1 installer registers COM components that are not backwards-compatible with newer TIA Portal versions. Use a dedicated engineering PC or a virtual machine for V15.1 work.

Installation Procedure

  1. Verify TIA Portal V15.1 is installed and a project opens without errors.
  2. Right-click SIMATIC_HMI_Template_Suite_V15_1.exe and select Run as administrator.
  3. Accept the EULA. Select Complete installation (recommended) or Custom if you need only the WinCC Professional subset.
  4. The installer registers the following libraries under %ProgramFiles%\Siemens\Automation\HMI Template Suite V15.1:
    • HMITS_Standard.ap15.1 – master library (faceplates, screen templates)
    • HMITS_ProEnergy.ap15.1 – energy-monitoring faceplates
    • HMITS_StyleGuide.chm – style-guide documentation
    • HMITS_SampleProject_V15_1.ap15_1 – reference project
  5. Reboot when prompted. TIA Portal must be closed during the reboot step to release locked COM servers.
  6. Open TIA Portal V15.1 and confirm the libraries appear under Libraries > Master Copies.

Integrating V15.1 Templates into a WinCC Project

  1. In TIA Portal V15.1, open the target WinCC project.
  2. Open the Libraries task card and switch to the Master Copies tab.
  3. Open HMITS_Standard.ap15.1 from the installation path.
  4. Drag the desired screen template (e.g., @HMITS_Home.pdl) into the project tree under HMI > Screens. TIA Portal creates a local copy and adds the required faceplate type instances.
  5. Compile the project (Project > Compile > All (rebuild)). Review the Info > Compile output for warnings of type Faceplate type version mismatch – these appear if any faceplate in the library has been touched and re-saved in a different TIA Portal version.
  6. Download to the target device or simulate with the RT Advanced / RT Professional simulator.

Template Suite Content Overview (V15.1)

Library / Folder Content Typical Use
@HMITS_Navigation Sliding / tabbed navigation structure Main process screens
@HMITS_Alarms Alarm line, alarm view, alarm log screen Diagnostics and alarm handling
@HMITS_Trends Trend view with archive selector Process value trending
@HMITS_Faceplates_Standard Motor, valve, PID, analog I/O faceplates Object-based operation
@HMITS_Faceplates_Energy Energy-monitoring faceplates (SENTRON PAC) Energy management screens
@HMITS_StyleGuide Color palette, typography, icon set Corporate design conformance

Migrating Templates from V15.1 to a Newer TIA Portal

When the underlying TIA Portal version on the engineering workstation is upgraded (e.g., V15.1 → V17), the V15.1 templates can be carried forward with the standard TIA Portal migration wizard:

  1. Open the V15.1 .ap15_1 project in the newer TIA Portal version.
  2. TIA Portal prompts to Upgrade. Confirm.
  3. Open the HMI Template Suite library delivered for the newer TIA Portal version (e.g., V17). Do not re-open the V15.1 master library in a V17 installation – the binary header differs and produces a LibraryLoadFault on every faceplate.
  4. Copy the migrated screen objects from the upgraded project into a fresh V17 project that references the V17 Template Suite master library.
  5. Compile and download.
Known issue: When migrating faceplate-type instances from V15.1 to V17+, Siemens' migration wizard updates the container instance but not always the type container reference. After migration, open Libraries > Type Versions, right-click the faceplate type, and select Update to latest version for every faceplate showing a yellow triangle. Failure to do so yields runtime alarm 190500 (faceplate version does not match type container).

Troubleshooting Matrix

Symptom Cause Resolution
Setup aborts with Error 1722: Windows Installer package problem Another TIA Portal installation is running Close TIA Portal, stop S7TraceService64.exe and re-run setup
Libraries appear empty in TIA Portal V15.1 V15.1 setup was installed after TIA Portal V16 was already present; COM hijack Repair TIA Portal V15.1 via Control Panel > Programs and Features > SIMATIC STEP 7 / WinCC V15.1 > Repair
Faceplate shows red question-mark icon at runtime Type container not downloaded to the panel Compile project with Type containers > Generate and re-download HMI
Alarm line stays empty despite active alarms Alarm class filter on the template is too restrictive Open @HMITS_Alarms.pdl, adjust Filter.BitMask in the alarm line properties
Color palette does not match the corporate style Project was opened in a TIA Portal that does not know the V15.1 palette Import @HMITS_StyleGuide.cst via Tools > Style > Manage
Trend view shows archive data offset by 1 hour Daylight saving time handling differs between V15.1 RT and V17 RT Set HMI runtime TimeBase = UTC on the trend view properties
Download link returns HTTP 404 on SIOS article 91174767 Siemens rotates the legacy download token Re-issue the request through SIOS Support request form

Licensing Notes

The HMI Template Suite is distributed as a free-of-charge engineering library. It does not require an additional SIMATIC HMI license beyond the TIA Portal WinCC Engineering license already on the workstation. However, every target runtime that consumes the template must hold a valid WinCC Runtime license (RT Advanced or RT Professional). When the template is used on a SIMATIC Comfort Panel, the panel's existing firmware license is sufficient.

OEM redistribution of customized templates derived from the suite is permitted under the terms of the SIMATIC HMI Template Suite EULA, provided that the SIMATIC HMI attribution is preserved in the project documentation.

Field-Commissioning Checklist

  • TIA Portal version on engineering PC matches the HMI Template Suite version exactly (V15.1 ↔ V15.1).
  • Project compile completes with zero errors and zero warnings under Info > Compile.
  • Libraries > Type Versions shows all faceplate types in green (latest version, no pending updates).
  • Type container regeneration has been executed before every download to the HMI.
  • Alarm classes referenced by the template exist in the project (default classes: Acknowledgement, Warning, Fault, System).
  • PLC tags exposed to the template are in the correct DB and accessible without pointer re-mapping.
  • Runtime language list matches the languages configured in the template (default: English, German).
  • Time synchronization between PLC and HMI confirmed (template uses Date_And_Time for trending and alarm timestamps).

Verification

  1. Open the migrated or newly created WinCC project in TIA Portal V15.1.
  2. Start the RT Advanced or RT Professional simulator (Online > Start simulation).
  3. Confirm the home screen renders with the expected color palette and navigation bar.
  4. Insert a tag-based alarm from the PLC simulation and confirm it appears in the template's alarm line within 2 s.
  5. Click an alarm entry and verify the navigation jumps to the associated detail screen.
  6. Open a trend view and confirm archive data is plotted with the correct time base.
  7. Download to the target Comfort Panel (if applicable) and perform the same visual checks on the panel.

FAQ

Where can I still download the Siemens HMI Template Suite V15.1?

The public download list on the SIOS article 91174767 typically shows the two most recent TIA Portal versions. For V15.1, submit a support request through the SIOS support entry at support.industry.siemens.com/cs/ww/en/sc/4868 or contact your regional Siemens sales representative.

Can I install HMI Template Suite V15.1 next to a newer TIA Portal?

Not recommended. The V15.1 installer registers COM components that conflict with TIA Portal V16 and later. Use a dedicated engineering PC, a virtual machine, or migrate the templates to the matching newer suite (V16/V17/V18/V19) instead of running V15.1 side-by-side with a newer portal.

Which TIA Portal version must I use with HMI Template Suite V15.1?

TIA Portal V15.1 with WinCC V15.1 is mandatory. Using V15 or V16 produces unresolved faceplate-type references and runtime errors such as 190500 (faceplate version mismatch). See the version compatibility matrix above for the full mapping.

Does the HMI Template Suite require an additional license?

No. The library itself is free of charge. However, every runtime that displays the templates (WinCC RT Advanced, RT Professional, or a SIMATIC Comfort Panel) must already hold a valid WinCC runtime license, which is independent of the Template Suite distribution.

How do I migrate V15.1 templates to TIA Portal V17 or later?

Open the V15.1 project in the newer TIA Portal and accept the upgrade prompt, then copy the screen objects into a fresh project that references the matching newer HMI Template Suite (V17/V18/V19). After migration, run Libraries > Type Versions > Update to latest version on every faceplate to clear the version-mismatch warning and avoid runtime alarm 190500.