How Do I Find an Image Indicator's Selected Image?

Ryan Tanaka5 min read
HMI ProgrammingOther ManufacturerTroubleshooting
Licensed PE Working through this on a live machine? A Maine-licensed engineer can take it from here — included with IMD hardware, by the hour for everything else. Book an engineer

In build mode, the panel’s Image Indicator shows five nearly identical backgrounds, but the image picker does not mark the image assigned to the selected entry. You cannot reliably read the current mapping from that picker. Start with a controlled runtime test or a reversible substitution; changing unrelated display settings will not expose the missing reference.

Stop Trying Fixes That Cannot Reveal the Selection

The first check is simple: select one Image Indicator entry, open Select Image, and look for an explicit selection marker or image name. If neither appears, stop searching the thumbnails for a hidden cue. The editor is not presenting the current reference.

What you see or try Why it does not solve the problem
Look for a thick border around one thumbnail The picker does not identify the assigned image with that visible marker.
Compare the five thumbnails by eye Minor image differences can disappear at thumbnail scale, so visual similarity cannot prove the mapping.
Click different library images hoping the current choice becomes obvious This changes the configuration instead of reporting it and can destroy the mapping you are trying to recover.
Adjust the indicator’s size, position, or other display properties Those properties affect presentation, not whether the picker exposes the referenced image.
Troubleshoot the image library first If all five images are available and display at runtime, the library is supplying them. The missing information is in the editor interface.

Do not repeatedly reselect likely images. That creates new uncertainty and wastes time because each guess alters the configuration.

Identify the Real Cause

The fault is an editor limitation: opening Select Image displays the image library without a dependable indication of which image is already assigned to the chosen Image Indicator entry. You are not overlooking a documented border or filename field in the described view.

That is not an image-rendering fault. The indicator can still select and display a background according to the system mode. The problem is observability during configuration: the stored association exists, but this properties workflow does not expose it clearly.

Treat the indicator as two separate mechanisms:

  • Selection logic: the system mode chooses one of the five entries.
  • Image mapping: each entry points to an image in the library.

A correct runtime picture proves that the active entry and its referenced asset can render. It does not tell you the asset name inside the picker.

Recover the Mapping with a Controlled Test

Use a copy of the project or the project’s normal backup mechanism before changing any entry. Then identify one mapping at a time.

  1. Record the current project revision and the Image Indicator object you are testing.
  2. List the five system modes and create a blank result column for the image observed in each mode.
  3. Place the system in the first mode using the machine’s normal, safe operating procedure.
  4. Observe the full-size Image Indicator rather than the library thumbnail. Record every distinguishing feature: color boundary, symbol placement, text, or another visible pixel-level difference.
  5. Repeat the observation for each remaining mode. Change only the mode between tests.
  6. Compare the runtime observations with full-size library images. Use a distinctive feature, not overall color or a thumbnail impression.
  7. If two assets remain indistinguishable, perform a reversible substitution in the project copy. Assign an unmistakable library image to only one entry, activate the corresponding mode, and confirm which entry changes.
  8. Restore the original assignment immediately after recording the result. Compare the test copy with the saved revision before returning it to service.

The substitution test isolates one entry, one reference, and one mode. If the unmistakable image appears under a different mode, the remaining problem is selection logic or entry order rather than image identification.

Distinguish an Image Error from a Mode Error

Drive the diagnosis from the active mode toward the displayed asset. Do not start by renaming or replacing library files.

  • If the expected mode is active and the expected background appears, record that mapping as verified.
  • If the mode changes but the background does not, check whether the selection logic actually chooses a different indicator entry.
  • If the correct entry is selected but the wrong background appears, correct that entry’s image assignment.
  • If two modes intentionally reference visually similar assets, inspect the images at full size before declaring a duplicate mapping.
  • If an image renders incorrectly in every mode that references it, investigate the asset itself rather than the mode-to-entry relationship.

Change one variable per test. Simultaneously editing mode logic and image assignments makes the result unusable because you cannot tell which change affected the display.

Verify All Five Mode-to-Image Associations

Verification must exercise every mode. A single correct screen proves only one branch of the mapping.

  1. Return the project to its intended image assignments.
  2. Activate each of the five modes separately.
  3. Confirm that the mode indication and displayed background change together.
  4. Record the observed image identity beside each mode.
  5. Cycle away from and back to each mode to catch stale-display or selection-transition problems.
  6. Reopen the project using the normal engineering workflow and repeat a representative check so the saved configuration, not an unsaved editor state, is being tested.

Use visible features that survive the indicator’s displayed size. If the only difference is too small to recognize on the panel, the operator faces the same ambiguity as the engineer.

Prevent the Same Ambiguity

  • Maintain a mode-to-image mapping in the project documentation.
  • Give library assets distinct, descriptive names wherever the engineering software supports naming.
  • Add a small, intentional visual discriminator to otherwise similar images when the application permits asset changes.
  • Keep a known-good project revision before remapping indicator entries.
  • After any asset replacement, test all five modes; matching dimensions or appearance does not prove that references remained correct.
  • Avoid deleting or replacing similar-looking assets until every reference has been accounted for.

The common pitfall is treating a visual match as identification. Use a recorded runtime mapping or a controlled substitution to establish identity.

FAQ

Can I see the selected Image Indicator filename in the image picker?

Not in the described properties workflow. The picker shows the library but does not provide a dependable filename or visible selection marker for the currently assigned image.

Does the selected image have a thick border?

No visible thick-border indication is provided in this case. Do not use thumbnail appearance as proof when the five images differ only slightly.

Can I recover the mapping without permanently replacing images?

Yes. Work from a saved copy, substitute one unmistakable image into one entry, activate its mode, record the result, and then restore the assignment. Stop if you cannot restore the original reference or cannot control the mode safely. Escalate through the product manufacturer’s official support channel when the editor still cannot expose the reference and a reversible test cannot identify it.

Back to blog