Installing STARTER V4.4 Help Files for SINAMICS Drives
Siemens STARTER (STARTER Commissioning Tool) V4.4 is the standard commissioning, parameterization, and diagnostic software for the SINAMICS drive family — including G110, G120, G120D, G130, G150, S110, S120, S150, and MV drives. The Help documentation is shipped as a separate component to keep the executable package compact, and is delivered in a multi-volume archive that must be extracted into a single shared target directory before any setup is started. This article provides the complete, field-proven procedure to install both the STARTER Help and the SSP (Startdrive/SINAMICS Support Package) Help, and to resolve the four most common installation failures that engineers report in production environments.
1. Overview of STARTER V4.4 and the Help Packages
STARTER V4.4 (current Hotfix level: V4.4 HF3) is distributed by Siemens Industry Online Support as a multi-volume ZIP set. The package is split because the uncompressed install tree exceeds 4 GB, which exceeds the size limit of the older Siemens download infrastructure. Each ZIP volume is roughly 1 GB. The contents of the Help subsystem are split across two distinct installers:
| Help Component | Installer Location | Order of Installation | Function |
|---|---|---|---|
| STARTER Help (core) | CD_1\SETUP.EXE (modify/repair mode) | First | Context-sensitive Help for STARTER UI, parameterization wizards, drive functions, fault/alarm lists |
| SSP Help | SSP_HELP\Setup.exe | Second (after STARTER Help) | Firmware-specific help, parameter descriptions, function diagrams, expert list documentation for each SINAMICS Support Package (SSP) |
| Readme | 01_Readme\ | Read-only | Release notes, version compatibility matrix, supported firmware/VFD catalog numbers |
2. Prerequisites
Before downloading or installing the Help subsystem, verify the following engineering workstation requirements:
- Operating system: Windows 7 SP1 (32/64-bit), Windows 10 (64-bit build 1607 or higher), or Windows Server 2012 R2. STARTER V4.4 is not certified for Windows 11 without the HF3 patch; consult the SINAMICS MICROMASTER STARTER V4.4 HF3 delivery release for the current OS matrix.
- Framework: .NET Framework 4.6.2 or higher, plus the Visual C++ 2015-2022 Redistributable (x86 and x64).
- Disk space: 4.5 GB free for the extracted multi-volume tree, plus 1.5 GB for the installed Help files (STARTER Help: ~700 MB; SSP Help: ~800 MB).
- User rights: Local administrator for the install only; runtime can be a standard user.
- Browser/Portal access: Siemens Industry Online Support account (support.industry.siemens.com) for the multi-volume download.
-
Archive tool: Any tool that preserves NTFS long path support (WinRAR 6.x, 7-Zip 22.x, or Windows native ZIP). Avoid extracting with PowerShell
Expand-Archiveon paths longer than 260 characters.
3. Downloading the STARTER V4.4 Package
Navigate to Product Support → Drive Technology → Selection and Engineering Tools → STARTER Commissioning Tool, or use the direct entry ID 26233208 in the Siemens support portal. The download selection exposes three install variants:
| Variant | Volumes Required | Use Case | Approx. Total Size |
|---|---|---|---|
| Minimal | 2 ZIP files (Vol1, Vol2) | Installs STARTER core only; help must be downloaded separately | ~2.0 GB |
| Complete | 3 ZIP files (Vol1, Vol2, Vol3) | Includes SSP_HELP, SSP_G110_G120, SSP_BT, SSP_DCM, etc. | ~3.5 GB |
| Complete + SinuTrain | 4 ZIP files | Adds SIMOTION/SINUMERIK integration and training toolbox | ~4.5 GB |
01_Readme\checksums.txt against the downloaded ZIPs. A corrupted Vol2 will pass extraction but fail setup with a missing-DLL error during Help registration.4. The Shared-Target-Directory Rule
The three (or four) ZIP volumes are designed to be unzipped into a single shared directory — not into three sibling directories. This is the architectural reason that the installer tree is split: each volume contains a partial set of the expected subdirectories, and the setup program scans the parent directory at runtime to discover them.
4.1 Choosing the Target Path
The path that you choose for the shared target directory must not contain any spaces. This is a hard-coded requirement of the legacy InstallShield engine used by STARTER V4.4. The following are forbidden:
-
C:\Program Files (x86)\Siemens\Staging\— fails (spaces around x86) -
C:\Users\John Doe\Downloads\Starter\— fails (space in username) -
C:\My Documents\Staging\— fails (space in My Documents)
Recommended staging paths:
C:\Siemens\StarterV44\D:\Staging\STARTER44\E:\Engineering\StarterV44_HF3\
The path must also remain under 200 characters after extraction. Paths above 260 characters trigger the "current path too long" error, even though the Windows MAX_PATH limit of 260 is technically the boundary. The InstallShield scanner truncates its internal buffer earlier than the OS, so a path of 230-250 characters will fail while the user sees the path length as acceptable.
4.2 Expected Directory Structure
After extracting all volumes into the shared target, the directory tree must look exactly as follows for the Complete variant. The order of subdirectories is irrelevant; their presence is not.
\...\GemeinsamesVerzeichnis\
01_Readme\
CD_1\
CD_2\
CD_3\
SSP_BT\
SSP_DCM\
SSP_FAMILY\
SSP_G110_G120\
SSP_HELP\
SSP_MV\
SSP_SIMOTION_INTEGRATED\
SSP_SINUMERIK_INTEGRATED\
Unsupported Tools\
For the Minimal variant (2 ZIPs), the CD_3\ and SSP directories other than SSP_HELP\ are absent. For the Complete + SinuTrain variant, an additional SSP_SINUTRAIN\ directory is present.
5. Installing STARTER (Main Application)
- Open the shared target directory in Windows Explorer.
- Navigate to
CD_1\and double-clickSETUP.EXE. Run as administrator. - Select the language for both the installer UI and the runtime UI (e.g., English, German, Chinese — these are independent selections).
- Accept the license agreement (Siemens Standard EULA, dated per release).
- On the Installation Type screen, choose Complete unless disk space is critical. Custom mode is for embedded PCs and excludes documentation.
- If you downloaded the Complete variant and the setup detects the
SSP_*\directories in the parent, the corresponding SSPs are automatically registered. Otherwise you will be prompted for each SSP. - Click Install. The progress bar takes 8-15 minutes on a modern workstation.
- Reboot if prompted. The STARTER installation creates two services:
SINAMICS Helper ServiceandSTARTER Routing Service(used for PROFINET/PROFIBUS device discovery).
6. Installing the STARTER Help
If the initial setup was run from a Minimal download or if the Help checkbox was deselected, the STARTER Help must be installed in a second pass. There is no standalone "Help only" ZIP; you must re-run the same SETUP.EXE and use the maintenance/modify mode.
- Launch
CD_1\SETUP.EXEagain (or use Control Panel → Programs and Features → STARTER → Change). - The installer detects the existing installation and enters Maintenance Mode.
- Select Modify → expand the Documentation node → check STARTER Help (English/German/etc.) → click Next.
- Confirm and complete. The Help files are written to
%ProgramFiles%\Siemens\Automation\STARTER\Help\and registered in the Windows Help store under the namespaceSiemens.SINAMICS.STARTER.Help. - Verify that
STARTER.chmis present and > 200 MB (size is a quick integrity check).
7. Installing the SSP Help
Once STARTER Help is registered, the SSP_HELP\ subdirectory of the shared target contains a dedicated Setup.exe that installs the firmware-specific help for all the SSPs present in the staging tree.
- Navigate to the shared target directory (e.g.,
C:\Siemens\StarterV44\). - Open
SSP_HELP\and double-clickSetup.exe. Run as administrator. - The installer scans for installed STARTER Help. If found, it proceeds. If not, it aborts with the dependency error described in Section 1.
- Select the languages (English mandatory; German, Italian, French, Spanish, Chinese optional).
- Select the SSPs to install. The list is pre-populated based on the
SSP_*\directories found in the parent. A typical Complete install yields:- SSP_BT (SINAMICS Basic Technology)
- SSP_DCM (DC Master)
- SSP_FAMILY (cross-SINAMICS documentation)
- SSP_G110_G120 (G110/G120/G120C parameter help)
- SSP_MV (Medium Voltage drives)
- SSP_SIMOTION_INTEGRATED (SIMOTION-coupled drives)
- SSP_SINUMERIK_INTEGRATED (SINUMERIK-coupled drives)
- Click Install. Typical install time: 4-8 minutes.
- The Help collection is registered in
STARTER.chw(compiled help workspace) and is now reachable via F1 in STARTER.
8. Verification
After both Help installations complete, perform the following five verification checks:
- F1 test: Launch STARTER, open any project, select a SINAMICS drive in the project tree, and press F1. A Help window should open with the parameter description of the selected object.
-
File presence: Confirm the following files exist on disk:
-
%ProgramFiles(x86)%\Siemens\Automation\STARTER\Help\STARTER.chm(≥ 200 MB) %ProgramFiles(x86)%\Siemens\Automation\STARTER\Help\SSP\<SSP_name>\<language>\*.chm
-
-
Registry keys: Open
regeditand confirm:-
HKLM\SOFTWARE\Wow6432Node\Siemens\Automation\STARTER\<version>\Helpexists with valueInstalled=1 -
HKLM\SOFTWARE\Wow6432Node\Siemens\SINAMICS\Helplists each installed SSP by GUID.
-
- Fault/alarm help: Open a drive's fault buffer, right-click a fault code (e.g., F07801), and select Help. The fault description should open in the contextual Help viewer.
- Function diagram: Open any expert parameter (e.g., p0840), press F1, and confirm that a function-diagram image (typically a 1xxx or 2xxx series number from the SINAMICS function diagram manual) appears inline.
9. Troubleshooting Common Errors
The four errors reported most frequently in the field are summarized below. Each row includes the verbatim error text, the root cause, and the corrective action.
| Symptom / Error Text | Root Cause | Resolution |
|---|---|---|
| "The setup cannot be continued because the STARTER Help has not been installed. Install the STARTER Help first." | SSP_HELP\Setup.exe was launched before STARTER Help was registered in the maintenance-mode install. | Run CD_1\SETUP.EXE in modify mode, enable STARTER Help, complete. Then re-run SSP_HELP\Setup.exe. |
| "Current path too long" when starting any setup.exe | Path to setup.exe exceeds ~230 characters, often because the staging directory is nested under a deep user profile (e.g., C:\Users\john.smith\AppData\Local\Temp\engineering\staging\...). |
Move the staging tree to a shallow path such as C:\Siemens\StarterV44\. Re-extract from the ZIPs if necessary. Do not nest under OneDrive or redirected folders. |
| Setup.exe runs but no help entries appear under F1 in STARTER | SSP Help was installed under a non-administrator account and the .chw index was written to a per-user path that is not active for the user running STARTER. | Uninstall the SSP Help from Programs and Features and reinstall using Run as administrator. Then launch STARTER once as administrator to rebuild the index, and once as the engineering user to verify. |
| "Setup could not find the required installation files" or missing-DLL errors during Help install | Vol2 or Vol3 ZIP was extracted into a sibling directory rather than the shared target, so the SSP directories are scattered across multiple roots. | Re-extract all ZIPs into the SAME directory. The shared target must contain all CD_*\ and SSP_*\ subfolders as siblings of 01_Readme\. |
| "Server not available" when following legacy link http://support.automation.siemens.com/WW/view/en/26233208 | The legacy support.automation.siemens.com host has been retired in favor of support.industry.siemens.com. |
Use the current portal URL: STARTER V4.4 HF3 delivery release for all download and version-information references. |
| STARTER Help installs cleanly but F1 only opens the empty STARTER.chm shell | Corrupted STARTER.chw workspace file (Help-API merge file). This typically follows an interrupted install or a virus scanner that locks the .chw during registration. |
Delete %AppData%\Siemens\STARTER\Help\STARTER.chw (if present) and rerun STARTER Help installer. Add %ProgramFiles(x86)%\Siemens\Automation\STARTER\ to the virus-scanner exclusion list. |
10. SINUMERIK and Hotfix 3 Special Considerations
Engineers commissioning SINAMICS drives that are integrated into a SINUMERIK 840D sl or SINUMERIK ONE controller must apply STARTER V4.4 HF3 rather than the base V4.4 release. The HF3 patch resolves a known conflict where a previously installed SINUMERIK Hotfix 3 version of STARTER would lock the registry keys for the SSP Help installer, causing the dependency check to fail even when STARTER Help is present.
The corrective procedure for SINUMERIK environments is:
- Uninstall any prior STARTER for SINUMERIK build (the Windows installer keeps the registry GUIDs even after file removal).
- Install STARTER V4.4 base from the standard 3-volume set.
- Apply the HF3 patch from the V4.4 HF3 delivery release page (the patch is a single ~80 MB MSI).
- Install STARTER Help via the modify-mode procedure described in Section 6.
- Install SSP_HELP\Setup.exe as described in Section 7.
11. Field-Proven Best Practices
-
Stage once, image many: Extract the multi-volume set to a network share at
\\fileserver\Siemens\STARTER_V44_HF3\and use that as the install source for every engineering workstation. This guarantees identical SSP selections across the team. - Disable Windows Search indexing on the install directory. The Help .chw/.chi index files are large and the Windows Indexer will hold write locks that interfere with maintenance-mode installs.
-
Document the build hash. After install, export the file list with
Get-ChildItem -Recurse | Get-FileHash -Algorithm SHA256and archive it with the project. Help content changes are tied to specific SSP build IDs (visible in Help → About in STARTER). -
Keep the staging directory read-only after install. This prevents accidental "run setup from a partially modified tree" scenarios when engineers double-click the staged
SETUP.EXEmonths later. -
Use the
Unsupported Tools\directory carefully. It contains diagnostic utilities (e.g., Trace Viewer, DriveLibCheck) that are not part of the supported STARTER release. Do not run them in production environments without Siemens approval. - On Windows 10 1909 and later, enable .NET Framework 3.5 SP1 via Turn Windows features on or off before installing STARTER. The Help engine still uses .NET 2.0-era COM interop that requires the legacy runtime as a compatibility shim.
12. Frequently Asked Questions
Why does the SSP Help installer say STARTER Help is missing even though I just installed it?
The SSP Help installer reads the registry at the moment Setup.exe is launched. If you installed STARTER Help in the same user session without elevation, the keys may have been written to HKCU rather than HKLM. Launch Setup.exe as administrator for both the STARTER Help modify-mode install and the SSP Help install.
Can I install STARTER V4.4 Help on Windows 11?
Yes, with STARTER V4.4 HF3 and after enabling .NET Framework 3.5 SP1 in Windows Features. The base V4.4 release is not certified for Windows 11 and will fail the setup pre-check. The V4.4 HF3 delivery release page lists the current OS certification matrix.
Do I need to re-install the Help files when I add a new SSP to the project?
Not necessarily. If the new SSP ships an updated SSP_<family>\ directory in a future download, you can drop the new Setup.exe from that SSP into the existing staging tree and re-run it. The Help installer merges the new content into the existing STARTER.chw workspace without requiring a full re-install.
What is the difference between CD_1, CD_2, and CD_3?
Each CD volume contains a partition of the STARTER install tree (binaries in CD_1, firmware images in CD_2, language packs and additional tools in CD_3). They must be extracted as siblings into the same shared target directory; extracting them into separate folders will break the installer's directory scan.
Is the SSP_HELP\ folder itself a different Help from the one in CD_1?
Yes. The STARTER Help (in CD_1\) covers the STARTER UI itself — project navigation, online/offline modes, scripting, trace functionality. The SSP_HELP\ covers drive-firmware-specific content: parameter-by-parameter descriptions, expert list, function diagrams, fault/alarm code descriptions, and BICO interconnections for each SINAMICS firmware version. Both are required for a complete engineering reference.
Can I install just the Help without installing the STARTER executable?
No. The Help installer registers its COM components and HTML Help viewer (hhctrl.ocx) under the STARTER application GUID, which is created only by the main installer. The cleanest path is to install STARTER in modify-mode, select Help, complete the install, then keep the STARTER executable even if you use Startdrive or SINAMICS Web Server for day-to-day commissioning.