Obtaining SINAMICS S120 Firmware 02.06.02.10: Official Methods

David Krause10 min read
SiemensTroubleshootingVFD / Drives
Licensed PE Working through this on a live machine? A Maine-licensed engineer can take it from here — included with IMD hardware, by the hour for everything else. Book an engineer

Overview

The SINAMICS S120 is a modular, high-performance drive system designed for precise motion control in advanced industrial machinery. As with any firmware-controlled automation platform, obtaining a specific firmware version such as 02.06.02.10 requires navigating Siemens' official distribution channels. Unlike consumer software, drive firmware is typically delivered only to authenticated partners and end customers with valid service agreements, and is supplied as a CompactFlash (CF) card image rather than a direct file download.

This article details the official pathways to obtain firmware version 02.06.02.10, the prerequisites for each method, and the verification steps required after installation. For users seeking a specific older build, the procedural constraints are identical to those for any current version, but the available download entry in the Siemens support portal may differ.

Firmware Version Architecture

SINAMICS S120 firmware uses a four-segment version number of the form MM.mm.bb.hh where each segment carries specific meaning within the Siemens release schema:

Segment Position Meaning
MM Major Functional generation / hardware platform generation
mm Minor Functional release with extended feature set
bb Bugfix Cumulative bug fixes; service pack level
hh Hotfix / Build Specific build identifier within the bugfix branch

For version 02.06.02.10, the interpretation is:

  • Major 02 – Second-generation S120 firmware (CU320, CU320-2, CU310 control units)
  • Minor 06 – Sixth functional release on that platform
  • Bugfix 02 – Second bugfix level on top of 02.06
  • Build 10 – Tenth build of bugfix 02
Compatibility note: Downgrading a Control Unit from a higher bugfix level (e.g., 02.06.02.10 -> 02.06.01.xx) typically requires a factory reset and full re-commissioning. Verify that the project STARTER / Startdrive archive is fully compatible with the target version before loading older firmware.

Identifying the Installed Firmware Version

Before requesting firmware, confirm the version currently installed on the Control Unit. Use one of the following methods:

  1. Operator panel AOP30 / BOP20: Navigate to Menu > Commissioning > Drive diagnostics > FW version. The full string V02.06.02.10 is displayed.
  2. STARTER / Startdrive (TIA Portal): Go online with the drive, right-click the Control Unit, and select Properties > Diagnostics > Firmware Version.
  3. Web server (CU320-2 with Ethernet): Open https://<CU_IP>/index.htm, then Diagnostics > Version.
Diagnostic field Value displayed
Control Unit firmware V02.06.02.10
Power Module firmware (if separate) Independent version, e.g., V02.05.04.00
Drive Object type SERVO / VECTOR / VECTOR_AC / TM
Bootloader Embedded in major segment

Official Distribution Channels

Siemens delivers SINAMICS firmware exclusively through three controlled channels. Public, direct downloads are not provided to anonymous users.

Channel Medium Prerequisites Typical use case
Siemens Industry Online Support portal CF card image (BIN file) Registered Support account; in some cases active service contract Standard end-customer update
Local Siemens office / Siemens Partner Pre-imaged CF card shipped or hand-delivered None for request; commercial relationship for warranty support Version not in public download catalog, OEM-specific builds
Copy from existing CF card Direct card-to-card clone Donor card with matching or higher version Field service, multi-machine fleet

Channel 1: Siemens Industry Online Support Portal

The official firmware catalog entry for SINAMICS S120 is published as Entry ID 33124038. The portal exposes only certain published versions for direct download; builds that are out of general distribution must be requested through Siemens support.

  1. Navigate to the SINAMICS S120 firmware entry in Siemens Industry Online Support.
  2. Sign in with a registered account. Anonymous access cannot trigger the download.
  3. Open the "Download" tab and verify the version shown matches 02.06.02.10.
  4. Select the package appropriate for your Control Unit (CU320 / CU320-2 / CU310 / CU310-2). The package contains a CF card image file (typically SINAMICS_S120_V02060210.bin) along with release notes and a hash manifest.
  5. Accept the end-user license agreement and start the download.
Access denial: If the download button is greyed out or the entry shows "no download available," the user account does not have download privileges for this entry. Siemens grants firmware download rights to accounts associated with a service contract or partner relationship. Request privileges through your Siemens sales contact before retrying.

Channel 2: Local Siemens Office or Siemens Partner

For versions not exposed in the public portal, or for users without portal privileges, the official recommendation is to contact the regional Siemens office or an authorized Siemens Partner. The partner can:

  • Verify the legitimate need for the specific build 02.06.02.10 (e.g., to match a fleet of identically commissioned machines).
  • Order a CF card pre-imaged with the requested firmware from Siemens spare-parts logistics.
  • Provide the firmware image on secured media for in-house flashing.

Request the following minimum information when contacting Siemens:

  • MLFB (order number) of the Control Unit, e.g., 6SL3040-1MA00-0AA0 (CU320) or 6SL3040-1MA01-0AA0 (CU320-2 DP)
  • Current installed firmware version (read from AOP30 or STARTER)
  • Project reference, machine serial number, and end-customer ID
  • Reason for the specific build (compatibility with existing project, OEM requirement, regression bug)

Channel 3: Copy from an Existing CompactFlash Card

If another machine in the fleet has the required firmware installed on its CF card, the image can be duplicated using a standard CF card reader and a tool such as dd (Linux), Win32 Disk Imager, or HDD Raw Copy Tool on Windows. The source card must be a Siemens S120 CF card (standard 1 GB or 2 GB) and must not be write-protected by the application.

  1. Power down the Control Unit and remove the CF card from its slot.
  2. Insert the source CF card into a PC-mounted or USB CF reader.
  3. Create a sector-by-sector image:
    sudo dd if=/dev/sdc of=sinamics_s120_V02060210.img bs=4M status=progress conv=noerror,sync
  4. Insert the target CF card (same capacity, Siemens-approved type) and write the image back:
    sudo dd if=sinamics_s120_V02060210.img of=/dev/sdc bs=4M status=progress conv=noerror,sync
  5. Reinsert the cloned card into the Control Unit, power up, and verify the firmware version on the AOP30.
Card type constraint: Use only Siemens-approved CF cards (e.g., 6SL3054-4AG00-2AA0). Consumer-grade cards may pass initial boot checks but cause sporadic faults under drive load (F08501, F08502 SD card errors).

Prerequisites for a Successful Firmware Update

Before any firmware is loaded onto a running S120 system, the following preconditions must be met:

  • Complete project backup using STARTER / Startdrive: Project > Save and Archive (creates a .zip archive with all parameters, scripts, and DCC charts).
  • Project consistency check: Online > Target system > Check consistency. Resolve any reported inconsistencies before loading.
  • Verify license keys are present and valid: Online > Licenses. Some firmware versions require a CF card with a valid license (CFL — Card Function License).
  • Confirm drive is in a safe state — the enable signal must be removed; the drive must be in o0000 (operation disabled).
  • For DRIVE-CLiQ components (Sensor Modules, Terminal Modules, Motor Modules), record their individual firmware versions, since these are managed separately and may need to be updated in a coordinated step.

Loading Firmware onto the Control Unit

Two official methods exist for loading firmware onto the Control Unit:

Method A: Pre-imaged CF Card Swap

  1. Insert the CF card (already imaged with V02.06.02.10) into the powered-off Control Unit.
  2. Power up the Control Unit. The bootloader reads /siemens/sinamics/ on the card and validates the firmware package.
  3. On the AOP30, the system prompts: New firmware detected. Perform update? Select Yes and enter the access level (manufacturer / service).
  4. Wait for the update to complete. Do not interrupt power during the update; interruption can brick the Control Unit and require return-to-factory service.

Method B: Firmware Update via STARTER / Startdrive

  1. In STARTER, connect to the drive online and select the Control Unit in the project tree.
  2. Right-click and select Target device > Firmware update.
  3. Browse to the firmware file (typically *.bin) extracted from the CF card image.
  4. Confirm the version displayed matches 02.06.02.10.
  5. Click Update. The tool erases the current flash, writes the new firmware, and reboots the Control Unit.
Do not mix: When updating via STARTER, the CF card in the Control Unit is typically not modified; the firmware is written to the internal flash. The CF card is used as a license dongle and parameter backup. Always update the CF card image separately to keep the two in sync.

Post-Installation Verification

After the firmware is loaded, run a structured verification sequence to confirm a clean installation.

  1. Version check: Confirm V02.06.02.10 is reported on the AOP30 and in STARTER.
  2. Parameter integrity check: Compare current parameter set against the archived project. Most parameters are retained; some new parameters introduced in 02.06 default to factory values.
  3. DRIVE-CLiQ topology check: STARTER > Topology should show all components in green; yellow indicates a version mismatch (often fixable by a component-specific firmware update).
  4. Fault buffer review: Check the fault buffer for any post-update faults (typical candidates: F01018, A01019, F08501). Acknowledge and clear after analysis.
  5. Commissioning test: Run a low-speed commissioning motion. Verify encoder feedback, current limit, and basic safety functions (STO / SS1) before returning the drive to production.

Troubleshooting Matrix

Symptom Likely cause Corrective action
Download button greyed out in portal Account lacks download privilege Contact Siemens sales to assign firmware-download rights
"No file available" message Build is not in public catalog Request the build through Siemens Partner or local office
F08501 / F08502 after CF card swap Non-approved CF card or bad image Re-image using Siemens-approved card; re-verify SHA hash
AOP30 stuck at "Booting..." Interrupted firmware update Re-attempt update with stable power; if persistent, RMA Control Unit
Drive reports older version after update Parameter p7826 (firmware update mode) not set, or wrong file loaded Verify p7826 = 1 before triggering; confirm filename
Licensed function (e.g., Safety Integrated Extended) missing after update License not on CF card Re-license via License Key Generator from existing License Key Report
DRIVE-CLiQ component shows F01452 (version conflict) Component firmware incompatible with 02.06.02.10 Update component firmware via STARTER > Update component firmware

Field-Proven Notes

  • Build 02.06.02.10 is typically a service-pack build targeted at specific customer escalations. In many fleets, public catalog versions such as HF11 of the 02.06 branch are functionally equivalent for general use; the specific build is usually required only to match the original commissioning version.
  • Always cross-check the firmware version printed on the CF card label against the version read by the AOP30. A mismatch indicates a card swap that was not reflected in the drive's parameter set.
  • When commissioning multiple machines from a single project, use the Series commissioning feature in STARTER to apply the project to each Control Unit after confirming the firmware version is identical.
  • For long-term fleet stability, document the installed firmware version in the machine's maintenance record and in the project's version header block.

References and Documentation

FAQ

How do I download SINAMICS S120 firmware version 02.06.02.10 directly from the Siemens website?

Sign in to Siemens Industry Online Support and open firmware entry 33124038. If your account has download privileges and the build is in the public catalog, the CF card image becomes available under the Download tab. Otherwise, request the build through your local Siemens office or authorized Siemens Partner.

Why is the firmware download not visible in my Siemens account?

Anonymous access cannot trigger a download, and even authenticated accounts may lack the "Firmware Download" right. Contact your Siemens sales representative to have the appropriate privilege assigned to your account under the relevant service agreement.

Can firmware be delivered as a file instead of a CF card?

Siemens ships S120 firmware as a CF card image. A partner can write the image to a Siemens-approved CF card (e.g., MLFB 6SL3054-4AG00-2AA0) before delivery, or you can copy the image yourself to a blank card using dd or a Windows imaging tool.

How do I verify that 02.06.02.10 is actually loaded after the update?

On the AOP30 navigate to Menu > Commissioning > Drive diagnostics > FW version, or in STARTER go online and open Properties > Diagnostics > Firmware Version on the Control Unit node. Both should display V02.06.02.10.

Is it safe to downgrade from a newer version to 02.06.02.10?

Downgrades on CU320 / CU320-2 typically require a factory reset (p0976 = 1) and full re-commissioning. Confirm that the saved STARTER / Startdrive project archive is compatible with 02.06.02.10 before downgrading, and back up the existing parameter set with p0971 = 1 first.

Back to blog