1. Overview: Programming the Omron CJ1M PLC
The Omron CJ1M is a compact modular PLC in the CJ-series family, supporting CPU types CJ1M-CPU11, CJ1M-CPU12, CJ1M-CPU13, CJ1M-CPU21, CJ1M-CPU22, CJ1M-CPU23, CJ1M-CPU11-ETN, and the Ethernet-equipped variants. Programming, configuration, and online maintenance of any CJ1M CPU require the CX-Programmer development environment, which is delivered as a component of the CX-One automation software suite. There is no other Omron tool that can build or upload an IEC 61131-3 / ladder project for CJ1M hardware.
Engineers frequently discover this constraint only after purchasing an incompatible software edition. This reference documents the licensing tiers, part numbers, hardware support matrix, and procurement workflow so that field service technicians, system integrators, and end users can select the correct CX-One license on the first purchase order.
CXONE-LT01C-V4) does not program CJ-series PLCs. Only the full CX-One license, ordered as CXONE-AL01D-V4 (or its regional equivalent), supports CJ1M project development, upload, download, and online edit.2. CX-One Suite Architecture
CX-One is a single installer that bundles multiple Omron configuration tools under one common shell. Per the official product family description, CX-One "allows users to build, configure, and program a host of devices such as PLCs, HMIs, motion-control systems and networks." See the CX-One Automation Software Suite family page for the canonical product listing.
| Component | Function | Used With CJ1M |
|---|---|---|
| CX-Programmer | Ladder / ST programming for CS/CJ/NJ/NX PLCs | Yes (mandatory) |
| CX-Integrator | Network and tag routing configuration | Yes (for Controller Link, EtherNet/IP) |
| CX-Simulator | Offline PLC simulation | Yes (CJ1M supported in full edition) |
| CX-Motion | Motion controller setup | Optional (CJ1M-MCH71 motion module) |
| CX-Position | Positioning unit configuration | Optional (NC module support) |
| CX-Designer | NS-series PT screen development | Optional |
| CX-Protocol | Serial protocol macro authoring | Optional (SCU modules) |
| CX-Process Tool | Loop and process tag configuration | Optional (CJ1M-CPU2x with process I/O) |
| CX-Drive | Inverter / servo parameter setup | Optional |
| CX-Thermo | Temperature controller setup | Optional |
| CX-FLnet | FL-net diagnostics | Optional |
All components share the same license key. Activating CX-One once enables every bundled tool, including CX-Programmer. The single-installer approach means that a technician who installs CX-One already has CX-Programmer present at Start → Programs → Omron → CX-One → CX-Programmer.
3. Edition Comparison: AL01D vs LT01C
The most consequential decision when procuring CX-One for CJ1M work is choosing between the two commercial editions. The "AL" suffix denotes the full Automation License, while "LT" denotes the entry-level Lite license. The "D" and "C" infixes in the part numbers reflect the maintenance / version generation of the license; "D" is the current generation superseding "C".
| Attribute | CXONE-AL01D-V4 (Full) | CXONE-LT01C-V4 (Lite) |
|---|---|---|
| Programs CJ1M / CJ2M / CJ1 / CS1 | Yes | No |
| Programs CP1 / CP1E / CP1H | Yes | Yes |
| Programs C200H / CQM1 (legacy) | Yes (via CX-Programmer) | No |
| Programs NJ / NX (Sysmac) | Yes (CX-Programmer 9.x+ via partial; full coverage in Sysmac Studio separately) | Limited / not recommended |
| Number of supported device families | All bundled components | Subset (micro PLCs and entry-level devices) |
| CX-Simulator included | Yes | No |
| CX-Motion / CX-Position | Yes | No |
| CX-Protocol / CX-Process | Yes | No |
| Typical retail (USD list, reference only) | ~$2,500 | ~$700 |
| License type | Single-user USB key or activation code | Single-user USB key or activation code |
| Suitable for CJ1M service work | Yes | No |
CXONE-LT01C-V4 for a CJ1M service job is a common procurement error. The installer will load CX-Programmer, but the device family selector will not list CJ1M CPUs, and project upload/download will fail. Verify the part number on the purchase order before signing the receipt.4. CJ1M Hardware Compatibility Matrix
Within the full CX-One license, CX-Programmer's supported device tree spans every CJ-series CPU Omron has shipped. The matrix below covers the CJ1M variants most often encountered in the field.
| CJ1M CPU Unit | Program Capacity | DM Area | EM Area | Built-in I/O | Notes |
|---|---|---|---|---|---|
| CJ1M-CPU11 | 5K steps | 32K words | — | — | Entry CPU |
| CJ1M-CPU12 | 10K steps | 32K words | — | — | — |
| CJ1M-CPU13 | 20K steps | 32K words | — | — | — |
| CJ1M-CPU21 | 5K steps | 32K words | 32K words × 1 bank | 10 inputs / 6 outputs | Built-in I/O |
| CJ1M-CPU22 | 10K steps | 32K words | 32K words × 1 bank | 10 inputs / 6 outputs | Built-in I/O |
| CJ1M-CPU23 | 20K steps | 32K words | 32K words × 1 bank | 10 inputs / 6 outputs | Built-in I/O + pulse I/O |
| CJ1M-CPU11-ETN | 5K steps | 32K words | — | — | EtherNet/IP port |
| CJ1M-CPU12-ETN | 10K steps | 32K words | — | — | EtherNet/IP port |
| CJ1M-CPU13-ETN | 20K steps | 32K words | — | — | EtherNet/IP port |
| CJ1M-CPU21-ETN | 5K steps | 32K words | 32K words × 1 bank | 10 in / 6 out | Built-in I/O + EtherNet/IP |
| CJ1M-CPU22-ETN | 10K steps | 32K words | 32K words × 1 bank | 10 in / 6 out | Built-in I/O + EtherNet/IP |
| CJ1M-CPU23-ETN | 20K steps | 32K words | 32K words × 1 bank | 10 in / 6 out | Built-in I/O + EtherNet/IP + pulse I/O |
All of the above CPU units are recognized by CX-Programmer once the full CX-One license is installed. The ETN variants expose the on-board EtherNet/IP port, which can be reached from CX-Programmer via FINS/UDP or FINS/TCP without any additional module configuration.
5. Part Numbers and Regional Variants
Omron publishes distinct catalog numbers per region to handle language, channel, and licensing agreements. The full CX-One license for CJ1M programming is sold under several SKU patterns. Always verify the part number quoted by your Omron distributor matches the regional format below.
| Region | Full License Part Number | Lite License Part Number | Typical Delivery |
|---|---|---|---|
| Europe (EU) | CXONE-AL01D-V4 |
CXONE-LT01C-V4 |
USB dongle or activation code |
| United States |
CXONE-AL01D-V4 (US SKU may append region code) |
CXONE-LT01C-V4 |
USB dongle or activation code |
| United Kingdom | CXONE-AL01D-V4 |
CXONE-LT01C-V4 |
USB dongle |
| Asia / Japan |
CXONE-AL01D-V4 (region-dependent suffix) |
CXONE-LT01C-V4 |
Activation code |
Both part numbers carry the -V4 suffix denoting the bundled component generation. V4 corresponds to the CX-Programmer 9.x build line and includes support for newer CJ1M firmware revisions. Lower-generation SKUs (e.g. CXONE-AL01C-V4) may install but will not always recognize the latest CJ1M CPU revisions; check with your Omron representative before committing.
Each license is sold as a single-user seat. Multi-seat installations require one license per concurrent user, since CX-One enforces a USB dongle or soft-key activation check at startup of any of its components.
6. License Procurement and Pricing
Pricing fluctuates by region, distributor, and ongoing Omron promotional bundles. Field-experience reference points, not contractual figures:
- Full license (AL01D-V4): Typically in the $2,000–$2,800 USD range when sourced through authorized distributors. Promotional or volume agreements may lower the effective unit price.
- Lite license (LT01C-V4): Typically in the $600–$900 USD range. Suitable only for CP1 / CP1E / entry-level work and will not unlock CJ1M device support.
CXONE-AL01D-V4 before placing the order. Lite licenses are non-refundable in most channels once the activation code has been issued.For short-duration service jobs, the cost of the full license can be amortized across multiple end customers. Many system integrators treat the full CX-One license as a baseline engineering tool and recover its cost via project billing.
7. Trial Version Workflow
Omron offers a 30-day trial of CX-One to qualified registrants. The trial install is the recommended pre-procurement validation step, especially when the end customer is paying for the service visit.
- Navigate to the official Omron CX-One trial request page for your region. The UK distribution page is published at Omron UK CX-One trial request; equivalent pages exist on the European and US industrial sites.
- Complete the registration form with company details. A download link and 30-day activation code are issued to the registered email address.
- Run the installer as administrator on a Windows 10 / Windows 11 workstation. CX-One V4 requires a 64-bit OS.
- Activate using the issued code. The trial exposes every component, including full CX-Programmer functionality with CJ1M device support.
- Connect to the target CJ1M via USB, serial, or EtherNet/IP (depending on the CPU variant) and confirm upload / download / monitor cycles work.
- When the 30-day window expires, the trial reverts to a view-only mode and prevents new project uploads. Replace with the purchased full license to restore full functionality.
8. CX-Programmer Feature Set for CJ1M
Once CX-One is installed and licensed, CX-Programmer becomes the primary tool for CJ1M work. The functions that matter most for service engineering are summarized below.
| Function | Menu Path in CX-Programmer | Service Use Case |
|---|---|---|
| Online connection via USB / Serial / Ethernet | PLC → Work Online / Online | Establish runtime link to CJ1M |
| Upload program from PLC | PLC → Transfer → From PLC | Recover lost source after CPU battery failure |
| Download program to PLC | PLC → Transfer → To PLC | Restore modified program after editing |
| Mode change (PROGRAM / MONITOR / RUN) | PLC → Operating Mode | Toggle between edit and runtime |
| Memory card transfer | PLC → Memory Card | Save project to compact flash |
| Force Set / Reset | Online → Force | Diagnose I/O without modifying logic |
| Watch window | View → Watch Window | Monitor addresses during commissioning |
| Cross-reference | View → Cross Reference | Locate all uses of a tag |
| Program print / PDF export | File → Print / Print Preview | Generate printed or PDF copy |
| Compare program vs PLC | PLC → Compare with PLC | Verify uploaded source matches in-PLC code |
CX-Programmer supports both ladder and structured text for CJ1M. Symbol / variable names, I/O comments, and rung comments are stored inside the project file (.cxp) and uploaded into the CPU as part of the program transfer, which is invaluable for service technicians trying to understand a foreign program.
9. Project Migration and Backup Strategy
Service organizations should adopt a standard workflow for backing up CJ1M programs whenever they are uploaded. CX-One provides several mechanisms:
-
Native project archive: After uploading, save the project as
.cxp(CX-Programmer project) and as.cxt(CX-Programmer tool / library archive). Store both in version-controlled directories. -
Memory card dump: Insert a compatible compact flash card into the CJ1M and use
PLC → Memory Card → Backupto write the entire program and parameter set to the card. The card can later be inserted into a replacement CPU to restore operation in minutes. -
PDF / print archive: Use
File → Print Previewfollowed by a PDF print driver to capture ladder, cross-reference, and I/O listing in a single document. This is the safest long-term archival format because it does not depend on CX-Programmer being available years later. - CX-Simulator integration: For testing program changes offline, use CX-Simulator (included in the full CX-One license) to load the project, simulate I/O, and verify logic before downloading to the live CJ1M.
PLC → Information), and the CX-Programmer build number in the backup folder. Project files from CX-Programmer 9.x cannot be opened by CX-Programmer 7.x without conversion; documenting the build avoids version mismatches during future service visits.10. Communication Setup for CJ1M
Connecting CX-Programmer to a CJ1M requires the correct driver selection in the Change PLC dialog and the appropriate physical or network path.
| CPU Variant | Recommended Path | CX-Programmer Network Type | |
|---|---|---|---|
| Default Address | |||
| CJ1M-CPU1x (no ETN) | USB / Serial (peripheral port) or via CJ1W-CIF11 / CIF12 | Toolbus (USB) / Host Link (Serial) | PLC node 00, network 00 |
| CJ1M-CPU2x (built-in I/O) | USB / Serial / optional Ethernet module | Toolbus / Host Link | PLC node 00, network 00 |
| CJ1M-CPUxx-ETN | On-board EtherNet/IP port | Ethernet (FINS/UDP, FINS/TCP) | IP assigned via CX-Integrator or rotary switches |
| Any CJ1M via CJ1W-ETN21 | Ethernet module in rack | Ethernet (FINS/UDP, FINS/TCP) | Module IP, unit number 0–F |
For EtherNet/IP-equipped CJ1M CPUs, set the rotary switches (or use the default IP 192.168.250.1 if all switches are 0xFF) and configure CX-Programmer's Ethernet network with the matching node and network numbers. CX-Integrator is used to verify routing through Ethernet and Controller Link modules.
11. Field-Proven Caveats and Best Practices
Several recurring issues surface in CJ1M service work. The following matrix lists the symptom, root cause, and corrective action.
| Symptom | Root Cause | Corrective Action |
|---|---|---|
| CX-Programmer device tree does not list CJ1M | CX-One Lite license installed (LT01C) | Purchase and install CXONE-AL01D-V4
|
| Online connect fails with "No response from PLC" | Incorrect network type or PLC node number | Verify network type matches port (Toolbus / FINS), confirm node 00 |
| Cannot upload program (read-protected) | CPU DIP switch or password protection enabled | Set the protect bit via CX-Programmer if password is known, or clear the CPU protection dip |
| Battery low error on power-up | CJ1W-BAT01 cell depleted | Replace battery with PLC powered to retain memory, then re-upload program |
| License key not recognized after OS upgrade | USB dongle driver mismatch | Reinstall Omron License Manager, replug dongle, reactivate |
| Project opens as read-only | Trial license expired | Apply purchased CXONE-AL01D-V4 license |
| Cannot connect via Ethernet after CPU replacement | New CPU has default IP, not the saved IP | Reconfigure IP via CX-Programmer or rotary switches |
Adopt these baseline practices for every CJ1M service visit:
- Always upload the program before any modification, save as
.cxp, and store a PDF copy. - Record the CPU firmware version and serial number; quote them on any future spare-part order.
- Verify the workstation's CX-One license level (Full vs Lite) before dispatching to site; nothing delays a service call like discovering a Lite license on arrival.
- Carry a known-good USB cable and a USB-to-serial adapter as backup paths to the peripheral port.
- Confirm CX-Programmer version matches the customer's environment;
CXONE-AL01D-V4ships CX-Programmer 9.x which can open but cannot save down to 7.x projects without explicit export.
12. FAQ
Which CX-One edition is required to program an Omron CJ1M PLC?
The full CX-One license, ordered as part number CXONE-AL01D-V4 (or its regional equivalent). The CX-One Lite edition (CXONE-LT01C-V4) does not include CJ-series device support in CX-Programmer and will not list CJ1M CPUs.
Can I use the CX-One trial to upload a CJ1M program for archival?
Yes. The 30-day trial activates the full CX-One feature set, including CX-Programmer with CJ1M support. Upload the project, save it as a .cxp file, and export a PDF copy before the trial expires; the PDF remains viewable without any license.
Does CX-One include a simulator for CJ1M offline testing?
CX-Simulator is included with the full CX-One license (CXONE-AL01D-V4) and supports CJ1M CPU emulation. It is not included in the Lite edition. Use CX-Simulator to validate program changes before downloading to a live CPU.
What is the typical cost of a CX-One full license for CJ1M work?
Reference pricing is approximately $2,000–$2,800 USD for CXONE-AL01D-V4, and approximately $600–$900 USD for the Lite edition CXONE-LT01C-V4. Final pricing varies by region, distributor, and ongoing promotional bundles. Always confirm the part number on the purchase order matches the full license.
Can CX-Programmer connect to a CJ1M-CPU23-ETN over Ethernet?
Yes. The on-board EtherNet/IP port on the -ETN variants is supported via FINS/UDP or FINS/TCP. Configure the CPU's IP address (default 192.168.250.1 when all rotary switches are 0xFF) and add an Ethernet network in CX-Programmer with the matching node and unit numbers. Use CX-Integrator if routing across multiple network layers is required.