Fixing LOGO! Soft Comfort V8.2 Installer Checksum and Version Mismatch
Siemens LOGO! Soft Comfort V8.2 is the engineering, simulation, and commissioning tool for the LOGO! 8.2 logic module family. Field engineers upgrading from V8.1.x frequently encounter download and installation anomalies: the installer splash screen reports "Hello, welcome to installer V8.1.1" on the 32-bit Linux package, the resulting binary identifies itself as V8.1.1 in the Info → About dialog, and the published SHA256 hash for the 32-bit setup.bin does not match the file served by the Siemens download portal. This reference documents the root cause, provides the correct verification procedure, and outlines the remediation steps required to obtain a genuine V8.2 build.
setup.bin payload before running the installer. A matching hash is the only reliable proof that the binary on disk corresponds to the build Siemens published. If the hash differs, the download is incomplete, corrupted in transit, or stale CDN content is being served.1. Product Identification and Catalog Reference
LOGO! Soft Comfort is delivered as a single-license installer for engineering the LOGO! 8 / LOGO! 8.2 (6ED1052-x) basic modules and the LOGO! 8.2 TDE text display. The product line and upgrade identifiers are catalogued in the Siemens product master and through authorized distributors:
| Identifier | Value | Source |
|---|---|---|
| Catalog (MLFB) — V8.2 individual license | 6ED1058-0BA08-0YA1 | Siemens DI Mall / SIEMENS STLOGO listing |
| Marketing name | LOGO! Soft Comfort V8.2 (LSC V8.2) | Siemens product family |
| Subsequent service pack | LOGO! Soft Comfort V8.2 SP1 (LSC V8.2.1) | Siemens support release notes |
| Associated firmware | LOGO! BM 8.2 / TDE 8.2 (ES ≥ V1.82.x) | Delivery release LOGO! 8.2 (ID 109752712) |
| Supported host OS — 32-bit | Windows 7 / 10 (x86), Linux x86 | Siemens download portal |
| Supported host OS — 64-bit | Windows 7 / 10 (x64), Linux x64 | Siemens download portal |
The official Siemens product page — Siemens LOGO! Software — is the canonical source for the latest service pack and for the on-line Help catalog. The 109752712 delivery release describes what LSC V8.2 adds: an additional LOGO! Web Editor Software Tool for creating custom web pages for LOGO! 8.2 basic devices without HTML authoring, and tightened Ethernet communication with the LOGO! 8.2 BM and TDE.
2. Symptom Catalog
Field reports cluster into five reproducible symptoms. Capture the exact symptom before escalating — it determines the remediation path.
| # | Symptom | Platform | Detection |
|---|---|---|---|
| S1 | Installer splash displays "Hello, welcome to installer V8.1.1" instead of V8.2 | Windows / Linux 32-bit | Splash text on setup.bin launch |
| S2 | After install, LSC Info → About reports V8.1.1 build, not V8.2 | Windows 32-bit | About dialog |
| S3 | SHA256 of setup.bin does not match the Siemens-published digest |
Linux x86 32-bit |
sha256sum setup.bin output |
| S4 | 64-bit download serves ~132 MB while the 32-bit package reports ~154–157 MB | Web portal | HTTP Content-Length or browser save dialog |
| S5 | Windows 10 SmartScreen blocks the unsigned installer | Windows 10 | SmartScreen warning dialog |
The presence of S1 + S2 + S3 together is the canonical signature of a stale or truncated 32-bit payload. Symptom S4 is the upstream cause: when the 64-bit download is smaller than advertised, the CDN is serving a previously-cached V8.1.1 build. Symptom S5 is independent of the version mismatch and applies to any LSC V8.x installer run on a stock Windows 10 image without SmartScreen trust for the Siemens certificate.
3. Root Cause Analysis
Three independent root causes converge to produce the symptom set:
-
Stale CDN cache for the 32-bit Linux build. The 32-bit
setup.binoriginally shipped on the Siemens automation sales-material CDN was superseded by a corrected binary, but a non-trivial fraction of HTTP requests continued to be served from the older object. The published SHA256 —0F44B8E5E0A59C633342E1933023257D412C23A981F1BD70E40C1132100CF764— corresponds to the corrected V8.2 binary; the older object returned a digest ending in...392525, which matches the V8.1.1 build. Siemens has since acknowledged the digest mismatch in the German technical forum thread referenced in the field report (ID 183162, post 735004). - Truncated 64-bit download. A 132 MB 64-bit payload is consistent with the V8.1.1 64-bit archive. A genuine V8.2 64-bit installer is ~157 MB; the complete V8.2 SP1 package is ~1.3 GB. When the 64-bit download is undersized, the same staleness or partial-cache condition applies.
-
In-app upgrade path returns 8.1.1. Selecting Update LOGO! Soft Comfort from within an already-installed LSC V8.1.1 invokes a launcher that re-runs the cached 32-bit
setup.bin. The in-app updater therefore propagates the same defect.
4. SHA256 Verification Procedure
Before executing setup.bin, compute the digest locally and compare to the value published on the Siemens download portal. This is the only deterministic check available in the field.
4.1 Linux / macOS
# Acquire the file
wget -O setup.bin "https://www.automation.siemens.com/salesmaterial-as/software/logo/upgrade/Linux/VM/linux32/setup.bin"
# Compute SHA256
sha256sum setup.bin
# Expected (V8.2 corrected build, 32-bit Linux):
# 0F44B8E5E0A59C633342E1933023257D412C23A981F1BD70E40C1132100CF764
If the printed digest differs — for example, an output terminating in ...392525 — the file on disk is the V8.1.1 binary. Discard the file, purge the browser / wget cache, and re-request with a cache-busting query string:
wget -O setup.bin "https://www.automation.siemens.com/salesmaterial-as/software/logo/upgrade/Linux/VM/linux32/setup.bin?v=$(date +%s)"
4.2 Windows
CertUtil -hashfile setup.bin SHA256
# Expected (V8.2 corrected build, 32-bit Linux):
# 0f44b8e5e0a59c633342e1933023257d412c23a981f1bd70e40c1132100cf764
PowerShell 5.1+ offers an equivalent:
Get-FileHash -Algorithm SHA256 .\setup.bin | Format-List
Cross-check that the resulting Hash field matches the value displayed on the Siemens download page. If the page and the local file disagree, do not run the installer — escalate to Siemens support with the digest, the request URL, and the date/time of the download.
5. Step-by-Step Resolution
The following procedure restores a genuine LSC V8.2 environment on a Windows or Linux host. It assumes a clean working directory and a fresh download.
-
Clean residual installations. Open Control Panel → Programs and Features and uninstall any prior Siemens LOGO! Soft Comfort entry. Delete the residual install tree at
%ProgramFiles%\Siemens\LOGOComfort(Windows) or/opt/siemens/LOGOComfort(Linux). Stale files prevent the new installer from overwriting V8.1.1 components. -
Clear browser and DNS caches. Cached CDN objects are the primary vector for the stale V8.1.1 build. Clear the browser cache, flush the local DNS resolver (
ipconfig /flushdnson Windows,systemd-resolve --flush-cacheson systemd-based Linux), and re-launch the browser in private/incognito mode. - Download from the canonical Siemens support entry. Navigate to the LOGO! 8.2 delivery release page — Delivery release LOGO! 8.2 (ID 109752712) — and follow the direct link to the V8.2 service pack. As of the V8.2 SP1 cut, the canonical full package is ~1.3 GB; an upgrade-only delta is ~157 MB. Either is acceptable provided the SHA256 verifies.
-
Verify the digest (Section 4). If the SHA256 of the 32-bit Linux payload equals
0F44B8E5E0A59C633342E1933023257D412C23A981F1BD70E40C1132100CF764, proceed. If it equals2ba12640fdb461f8f7640b48faea2923edeea2806ae356bede0f8657cbbcd5e5(the digest reported by an affected user) or any value terminating in...392525, the binary is V8.1.1 and must be discarded. -
Run the installer as administrator. On Windows, right-click
setup.exe(or the extractedsetup.binwrapper) and choose Run as administrator. The UAC prompt is expected; approve it. - Confirm the splash banner reads "installer V8.2". A V8.1.1 splash is diagnostic of a stale or truncated payload regardless of file name.
-
Validate the post-install version. Launch LSC and open Help → Info (or the Help menu's About entry on localized builds). The version line must read
V8.2.0for the initial release orV8.2.1for SP1. Anything else indicates that the V8.1.1 components were not fully overwritten. -
Connect to a LOGO! 8.2 BM (optional verification). With a LOGO! 8.2 basic module on the local Ethernet subnet, use Tools → Ethernet → Connect. A successful online connection plus a firmware read of
ES V1.82.xor later confirms end-to-end V8.2 compatibility.
6. Windows 10 SmartScreen Workaround
Windows 10 SmartScreen blocks the LSC V8.2 installer on hosts that do not yet have a trust record for the Siemens certificate. This is independent of the version mismatch and is encountered on every clean Windows 10 image.
- In the SmartScreen warning dialog, click More info.
- Confirm that the publisher field reads Siemens AG (or a Siemens-internal signer for the V8.2 build). If the publisher is blank or names an unrelated organization, abort — the binary does not come from Siemens.
- Click Run anyway.
To suppress the prompt permanently within a controlled engineering environment, the installer binary can be added to the local AppLocker allow-list or distributed via Group Policy Software Installation. The certificate is published in the Siemens support portal as part of the signed-installer bundle; do not sign the binary with a third-party certificate.
7. LOGO! 8.2 Hardware Compatibility
LSC V8.2 is engineered against the LOGO! 8.2 BM firmware (ES ≥ V1.82.x) and the LOGO! TDE 8.2 text/graphic display. Per the delivery release (ID 109752712), key runtime features exposed by LSC V8.2 include:
- LOGO! Web Editor. A new tool bundled in LSC V8.2 for authoring custom web dashboards served by the LOGO! 8.2 BM's integrated web server. Projects target user-defined variable tags, eliminating the need to hand-author HTML.
- Enhanced Ethernet diagnostics. Extended online diagnostics for the LOGO! 8.2 Ethernet interface, including a S7-compatible variable view and per-port counters.
- TDE 8.2 message-page editor. Updated editor for the LOGO! TDE 8.2 with new bar-graph, curve, and bitmap widget primitives.
A program authored in LSC V8.1.x loads in LSC V8.2 without conversion. Down-conversion to a LSC V8.1.x project is not supported for programs that use the Web Editor variables or the TDE 8.2 widgets.
8. In-App Updater vs Standalone Installer
The in-app Update LOGO! Soft Comfort mechanism is convenient but inherits the CDN staleness problem described in Section 3. Where the in-app updater reports already on V8.2 but the About dialog still shows V8.1.1, the updater has confirmed the user's installed version against the same cached payload. In that condition, only the standalone installer from the support entry can deliver the corrected V8.2 binary.
| Property | In-app updater | Standalone installer |
|---|---|---|
| Source | Reuses cached setup.bin
|
Re-downloaded from Siemens support |
| Cache-bust capable | No | Yes (manual query string) |
| SHA256 verifiable | Indirect (post-install About) | Direct (pre-install hash) |
| Suitable for V8.1.1 → V8.2 upgrade | No (propagates defect) | Yes |
9. Troubleshooting Matrix
| Symptom | Likely cause | First action | Escalation |
|---|---|---|---|
| S1 — Splash shows 8.1.1 | Stale CDN cache / truncated 64-bit payload | Re-download with cache-buster; verify SHA256 | Pull V8.2 SP1 (~1.3 GB) full package from support entry |
| S2 — About dialog shows 8.1.1 | Installer delivered V8.1.1 binaries | Uninstall, delete install tree, re-install from support entry | Compare pre/post install SHA256 to confirm payload |
| S3 — SHA256 mismatch on 32-bit Linux | Stale setup.bin on CDN |
Use cache-busted URL; re-hash | Open Siemens support ticket with URL, digest, timestamp |
| S4 — 64-bit download is ~132 MB | CDN serving V8.1.1 64-bit archive | Force refresh; re-download V8.2 64-bit ~157 MB | Use the SP1 full package as a fallback |
| S5 — SmartScreen block | Unsigned / unfamiliar certificate | Verify publisher = Siemens AG; click Run anyway | If publisher field is blank, abort and re-download |
10. Verification Checklist
-
sha256sum setup.binmatches0F44B8E5E0A59C633342E1933023257D412C23A981F1BD70E40C1132100CF764(32-bit Linux) or the equivalent digest published for the 32-bit Windows / 64-bit Windows / 64-bit Linux payloads. - Installer splash banner reads V8.2.
- About dialog reports
V8.2.0orV8.2.1(SP1). - An online connection to a LOGO! 8.2 BM succeeds and reads firmware ≥ ES V1.82.x.
- The LOGO! Web Editor entry is present under the Tools menu (new in V8.2).
11. Frequently Asked Questions
Why does my LSC V8.2 installer splash say "installer V8.1.1"?
The 32-bit setup.bin on the Siemens automation CDN has, in some windows of time, been a V8.1.1 binary relabeled as V8.2. Compare the SHA256 of setup.bin to the value 0F44B8E5E0A59C633342E1933023257D412C23A981F1BD70E40C1132100CF764; a mismatch confirms the stale payload. Re-download with a cache-busted URL or pull the V8.2 SP1 full package (~1.3 GB) from the Delivery release LOGO! 8.2 (ID 109752712) entry.
What is the correct SHA256 of the LOGO! Soft Comfort V8.2 32-bit Linux setup.bin?
The V8.2 corrected 32-bit Linux setup.bin digests to 0F44B8E5E0A59C633342E1933023257D412C23A981F1BD70E40C1132100CF764. A digest ending in ...392525 indicates the stale V8.1.1 build. Verify with sha256sum setup.bin (Linux/macOS) or CertUtil -hashfile setup.bin SHA256 (Windows).
How large should the LSC V8.2 64-bit installer be?
A genuine V8.2 64-bit Windows or Linux installer is approximately 157 MB. A 132 MB download is consistent with the V8.1.1 64-bit archive and should be discarded. The complete LSC V8.2 SP1 full package is approximately 1.3 GB.
Does Windows 10 SmartScreen block the LSC V8.2 installer?
Yes, on hosts without a prior trust record. Click More info, confirm the publisher is Siemens AG, then click Run anyway. If the publisher field is blank, the binary is not the Siemens build and should not be executed.
What new features does LSC V8.2 add over V8.1.x?
Per the Siemens delivery release (ID 109752712), LSC V8.2 introduces the LOGO! Web Editor for authoring custom web pages served by the LOGO! 8.2 BM, extended Ethernet diagnostics, and an updated TDE 8.2 message-page editor with bar-graph, curve, and bitmap primitives. Target firmware is LOGO! BM / TDE 8.2 with ES ≥ V1.82.x.