A sensor-enable checkbox on the Raven display confirms that the user interface exposes a low-bin-level function. It does not, by itself, confirm that the Raven RCM LVL1 contains the required input hardware, that the Montag air seeder harness includes a sensor branch, or that the option is plug-and-play. Resolve those three points before connecting a sensor.
Separate confirmed facts from open questions
| Item | Evidence status | Engineering decision |
|---|---|---|
| Low-bin sensor checkbox | Present on the Raven screen | Treat it as software configuration only until the hardware path is verified. |
| Controller | Raven RCM LVL1 | Confirm that this exact controller configuration supports the input. |
| Implement | Montag air seeder | Inspect its installed harness for a documented sensor connector. |
| Tractor and display | Deere 9R 590 with G5 display | Confirm how the resulting alarm or status is presented; the evidence does not establish display compatibility. |
| Connector and pinout | Unknown | Do not infer a connection point from the checkbox. |
| Sensor electrical type | Unknown | Do not select or wire a sensor until its required signal and supply are documented. |
Verify the complete input path
Identify the exact installed RCM LVL1 and implement-harness documentation, then trace the circuit from the proposed bin sensor location to the controller. The required evidence is a documented connector, pinout, sensor supply, return, and input signal specification. If any part is absent, the option cannot yet be classified as plug-and-play.
Do not assume that an unused connector is the sensor input. Verify its function against Raven or Montag documentation or through an official support channel before applying power, ground, or a signal.
Configure and prove the alarm
After confirming and installing a compatible sensor through the documented connection, enable the displayed sensor checkbox. Test both material-present and low-level states while observing the Raven interface and the G5 display. Accept the installation only if the indicated state changes correctly and the intended low-bin warning appears without creating unrelated faults.
If the checkbox can be enabled but the state never changes, recheck the documented input path, sensor power, return, signal, and harness continuity. The available evidence does not identify a connector, pin assignment, sensor model, or controller-specific diagnostic code.
FAQ
Is the Raven RCM LVL1 low bin sensor plug and play?
The evidence confirms only that the Raven screen has a sensor checkbox. Verify the RCM LVL1 input capability, Montag harness branch, connector pinout, and sensor electrical requirements before treating it as plug-and-play.
Where does a low bin level sensor connect on a Raven RCM LVL1?
No connection point or pinout is provided in the available evidence. Use documentation for the exact installed RCM LVL1 and Montag harness, and do not connect to an unidentified spare plug.
How do I test a Raven low bin level warning on a Deere G5 display?
After installing the documented compatible sensor and enabling its checkbox, exercise both material-present and low-level states. Verify that the Raven sensor state changes and that the intended warning appears on the Deere G5 display.