Reinstall LOGO! Soft Comfort: Recover the Engineering Software After a Computer Change
Siemens LOGO! Soft Comfort is the engineering software for the LOGO! logic module family. Unlike TIA Portal, STEP 7, or S7-PLCSIM, the LOGO! engineering tool does not use a centralized license key server, an electronic license (eLicense) file, or a Software Protection Key (USB dongle). The right to use the software is bound to a physical installation on a PC, originally established by a CD or DVD that was purchased from Siemens or a Siemens distributor. When a computer is replaced, lost, or re-imaged, the engineering environment is not recovered by entering a serial number; it is recovered by reinstalling from the original media or by ordering a replacement DVD. This article documents the exact recovery procedure, the upgrade path, and the verification checks required to bring a new PC back to a working LOGO! Soft Comfort environment.
1. The LOGO! Soft Comfort Licensing Model
Siemens' general automation software portfolio uses a floating or node-locked license key system managed by the Automation License Manager (ALM). LOGO! Soft Comfort is an intentional exception in this portfolio, kept simple for the small-machine and building-services audience it targets.
| Feature | LOGO! Soft Comfort | TIA Portal / STEP 7 |
|---|---|---|
| License mechanism | Original CD/DVD must be present or existing install must be upgraded in place | ALM license key (node-locked, floating, or trial) |
| Activation | None — installer writes the right-to-use flag | ALM transfers a license to the local hard drive |
| Reinstall on new PC | Re-insert original DVD or order a replacement DVD | Deactivate old PC, activate new PC from license key |
| Trial version | Not available as a separate full product | 21-day trial downloadable from SIOS |
| Upgrade distribution | SIOS download (requires base CD or installed LSC) | SIOS download + license already covers the new version |
The practical consequence: if you have only a single CD from years ago and that CD is unreadable, lost, or in a different country, you cannot independently create a working LSC environment on a fresh laptop. You must obtain the original media again. The remainder of this article shows the three legally supported paths to do that.
2. Prerequisites for Recovery
Before choosing a recovery path, verify the following on the machine that needs LSC:
- Operating system: LOGO! Soft Comfort V9 supports Windows 10 (64-bit, version 1809 or later) and Windows 11. Earlier versions of LSC (V7, V8) supported Windows 7 and Windows 8.1 — confirm what the new PC can run before ordering media.
- Administrator rights: The install requires local administrator privileges, including the right to install and start services such as the LOGO! Access Tool.
- Optical drive or virtual drive: For DVD-based install, the new PC needs either a working DVD drive or the ability to mount an ISO image. Most modern field laptops lack an optical drive, so a USB DVD drive or a virtual mount (e.g. the Windows built-in ISO mount) is required.
-
Existing LSC project files: Locate the original
.lsc(LOGO! Soft Comfort V6 / V7),.lsc2(LOGO! 8 and later), or.lld(LOGO! Logic Diagram) project files. These survive PC changes; only the editor needs to be reinstalled. - Siemens Industry Online Support (SIOS) account: Required to download any available upgrade packages. Registration is free at the Siemens support portal.
3. Option A — Order a Replacement DVD from Siemens
This is the cleanest path for engineers working away from their home office. Siemens sells replacement LOGO! Soft Comfort media through its standard distribution channels.
- Identify the article number. The LOGO! Soft Comfort DVD is sold under the Siemens article number 6ED1058-0BA02-0YA8 (LSC DVD) for the V8.x family, with V9.x sold via its own successor article. Always confirm the current article number with your local Siemens distributor before placing the order.
- Contact a Siemens distributor in the country where you are currently working. Every Siemens regional office can ship media internationally; typical delivery is 3–7 business days inside the EU and 5–14 days outside the EU, depending on courier option.
- Order a printed invoice with the order. The invoice acts as your proof of license in any future audit or for transfer to a new employer.
- When the DVD arrives, store it in a protective sleeve and image it (
.isofile) to a network share so a third recovery never has to depend on a single physical disc.
4. Option B — Use a Colleague's Original DVD
For engineers embedded in a maintenance team, the DVD does not need to be the engineer's own. Any valid LOGO! Soft Comfort CD or DVD from any PC in the organisation can be used to install the full software on a different machine. The license is tied to the existence of a valid LSC media purchase, not to a specific person.
- Have a colleague image their original LOGO! Soft Comfort DVD to an
.isofile. Use any standard imaging tool (e.g. ImgBurn, the Windows 10/11 built-in recorder, orddon Linux). - Mount the ISO on the new PC (right-click → Mount in Windows Explorer).
- Run
Setup.exefrom the mounted volume with administrator rights. - Keep the ISO on a shared engineering share for the duration of the project; do not modify or copy the original disc.
5. Option C — Download an Upgrade from SIOS
If a full version of LSC is already installed on a PC that you can reach (e.g. a home workstation, a colleague's laptop, or a virtual machine in your company's data center), the upgrade path is the fastest route to a working install on the new PC.
- Open the Siemens Industry Online Support portal and search for "LOGO! Soft Comfort" in the downloads area. The latest published version is V9.0 (and any subsequent service packs). The article that lists the current download is reachable from the product page at LOGO! Software – Simple Engineering for LOGO!.
- Download the upgrade executable. This is a self-extracting installer, typically named
LogoSoftComfort_V9_x_x_x_x.exe. - On the new PC, run the upgrade installer. The installer will detect whether a previous version of LSC is already installed. If it is, the upgrade proceeds in place.
- If no prior LSC exists on the new PC, the upgrade installer will request that an LSC CD or DVD be inserted in a drive. Mount the original ISO (from Option A or Option B) in a virtual drive at this point and click Retry. The install then completes as a full V9 install.
- Reboot the PC when prompted. The installer registers the LOGO! Access Tool service for Ethernet communication with LOGO! 8 / LOGO! 8.3 hardware.
6. Step-by-Step Installation Procedure (Reference Flow)
Use this flow as a checklist regardless of which of the three recovery options above you chose.
- Pre-install verification. Confirm Windows version, free disk space (minimum 1 GB recommended, 3 GB preferred for V9 with project archives), and the presence of an admin account.
-
Insert or mount the original media. Either physical DVD in a USB DVD drive, or the
.isomounted as a virtual drive letter. -
Launch the installer. Browse to the mounted volume and double-click
Setup.exe. If User Account Control prompts, accept with admin credentials. - Accept the license agreement. The license text is the standard Siemens Automation License Terms. Read and accept.
-
Select destination. Default path is
C:\Program Files\Siemens\LOGO Soft Comfort V9. Use the default unless corporate standards dictate otherwise. - Select components. Typical selection: LOGO! Soft Comfort Editor, LOGO! Access Tool, and LOGO! Web Editor (the latter is included with V9 for direct browser-based visualization of the connected LOGO! 8.3 BM).
- Install. Progress typically takes 2–5 minutes on a modern laptop.
- Finish and reboot. Some versions require a reboot to register the LOGO! Access Tool Windows service used for Ethernet communication.
- First launch. Start LSC. If the install was a clean media install, the software launches in the language matching the OS. Switch language via Extras → Options → General → Language if needed.
7. Restoring Existing LOGO! Projects
The project files are not coupled to the PC install. They live on disk and can be carried on a USB stick, a cloud share, or in a version control system. After reinstall, restore the project files to a working folder and open the file in the new editor.
| File extension | Generated by | Minimum LSC version | Can be opened by |
|---|---|---|---|
.lsc |
LOGO! Soft Comfort V6 / V7 | V6.0 | V7, V8, V9 (with prompt to convert) |
.lsc2 |
LOGO! Soft Comfort V8+ for LOGO! 8 (BM) | V8.0 | V8.x, V9.x |
.lld |
LOGO! Web Editor / LOGO! on-device editor | LOGO! 8.2 firmware | Re-importable as logic blocks |
.bin / .lma
|
LOGO! 8 BM card slot archive | Firmware on BM | Imported via Tools → Import → Memory Card |
When LSC opens a project from an older LSC version, it offers a one-way conversion. Always save the converted project with a new name (e.g. PumpControl_v9.lsc2) to keep the original-version file as a fallback. There is no reliable reverse path from a converted project back to an older editor.
8. Connecting to the LOGO! Module
After the editor is installed, verify PC-to-LOGO! communication before trusting the recovery:
- Connect the LOGO! 8 or LOGO! 8.3 BM to the PC with a standard Ethernet patch cable. LOGO! 8 introduced an integrated Ethernet port; no special cable is required.
- Open Tools → Transfer → PC ↔ LOGO! (or click the Ethernet icon in the toolbar).
- Set the PC's Ethernet interface to a static address on the same subnet as the LOGO!. Default LOGO! IP is
192.168.0.100with subnet255.255.255.0. Set the PC to192.168.0.10/255.255.255.0. - Click Online. The editor should report the connected LOGO! hardware, the firmware version, and the project name currently loaded in the module.
- Use Upload from LOGO! → PC to retrieve the live project as a safety backup before making changes.
9. Verification Checklist After Reinstall
Run through the following checks before declaring the recovery complete:
| Check | How to verify | Expected result |
|---|---|---|
| Editor opens | Launch LSC, observe splash screen | Splash displays "LOGO! Soft Comfort V9.x" with no error dialog |
| Project loads | File → Open → choose the saved .lsc2 file |
Diagram renders, FBD / LAD elements appear |
| Simulation works | Tools → Simulation (F3) | Simulation panel appears, inputs toggle outputs |
| Online connection | Tools → PC ↔ LOGO! | Connected status, firmware version displayed |
| Upload from LOGO! | Transfer → Upload from LOGO! → PC | Project from the device downloads to a new file |
| Web Editor (V9 only) | Right-click on connected LOGO! 8.3 BM → Open Web Editor | Browser opens the LOGO! web UI |
10. Troubleshooting Matrix
| Symptom | Likely cause | Resolution |
|---|---|---|
| Installer asks for the CD and does not accept the mounted ISO | Virtual drive letter changed or the ISO was not mounted when the installer polled for the disc | Re-launch the installer with the ISO already mounted; do not mount the ISO from inside the installer dialog |
| Upgrade download refuses to install on a clean PC | No prior LSC install, no original CD detected | Obtain the original DVD; do not attempt to bypass the check with registry edits |
| Online connection shows "no LOGO! found" | PC subnet does not match LOGO! subnet | Set PC to 192.168.0.x / 255.255.255.0; disable other network adapters |
| Transfer fails with a timeout | Windows Firewall is blocking the LOGO! Access Tool | Allow the service in Windows Defender Firewall; restart the LOGO! Access Tool service |
Older .lsc project will not open in V9 |
Project from pre-V8 hardware and not convertible | Install the matching older LSC version on a separate PC to export the logic, or rebuild the diagram manually in V9 |
| Splash screen reports "Demo mode" with a runtime limit | Installer did not detect a valid original media | Re-run the install with the original CD/DVD in a drive; do not run the upgrade from a copy of the upgrade that was extracted without the base media |
| LOGO! Web Editor is greyed out | Connected hardware is a LOGO! 8 (pre-8.3) without the web server option | Web Editor requires LOGO! 8.3 BM (firmware ≥ 1.0); for older hardware, use the integrated Web Server configuration in the device's web UI instead |
11. Field-Proven Practices for Avoiding This Situation
-
Image the original DVD on receipt. Create an
.isofile the first day the DVD arrives and store it in two independent places (cloud + NAS). The DVD itself is media that degrades; the ISO is data. -
Keep a virtual machine with LSC preinstalled. A 40 GB Windows VM with LSC V8.3 + V9 and the original
.isomounted once can be copied to a new laptop in minutes — the upgrade chain is preserved. - Centralise projects in source control. Git, SVN, or even a shared folder with daily snapshots, ensures that a lost PC does not mean a lost program. The editor is recoverable; the customer-specific logic often is not.
- Document the LOGO! firmware version on the project. Place a comment block at the top of every diagram noting the target LOGO! hardware and the LSC version used to author it. This avoids compatibility surprises when a different team member opens the project.
- Carry a USB DVD drive on long assignments. When working abroad, a $25 external DVD drive is the difference between one business day of downtime and two weeks of shipping.
12. Notes on Web-Based and Cloud Tools
Siemens publishes a set of browser-based helpers around the LOGO! family. These are not substitutes for LOGO! Soft Comfort but are useful when the editor is unavailable.
- LOGO! Web Editor (V9): A small editor integrated into the LOGO! 8.3 BM that lets the engineer change logic from any browser pointed at the module's IP. Useful for on-site emergency edits when LSC is not available, but limited to small diagrams.
- LOGO! Access Tool: A Windows service that exposes LOGO! 8.3 variables to OPC UA / MQTT / HTTP clients. It is installed with LSC V9 and is the path to integrating LOGO! into higher-level SCADA systems.
-
LOGO! Web pages (custom): Built inside LSC V9 using the Web Editor; the resulting
.binuser pages are stored on the LOGO! 8.3 BM and served athttp://<LOGO_IP>/.
The full Siemens product overview and the link to the latest LSC V9 download are maintained on the official LOGO! Software – Simple Engineering for LOGO! page. The bundled LSC Online Help PDF — the same content as the in-application Help → Contents — is the definitive reference for every menu and dialog and can be downloaded separately as LOGO! Soft Comfort Online Help (PDF).
13. Frequently Asked Questions
Does LOGO! Soft Comfort have a license key like TIA Portal?
No. LOGO! Soft Comfort uses CD/DVD-based licensing. There is no license key, no ALM activation, and no eLicense file. The right to use the software is established by installing from a purchased CD or DVD, or by upgrading an existing install using a SIOS download in the presence of that original media.
Can I download a full version of LOGO! Soft Comfort from Siemens?
No. Siemens only publishes point-release upgrades as downloads. A full install always requires the original CD or DVD to be inserted (or its ISO mounted) in a drive during the upgrade. Without the original media, no fully working install is technically possible.
Which is the current version of LOGO! Soft Comfort?
The current release is LOGO! Soft Comfort V9.0, which supports the LOGO! 8.3 BM hardware and ships with the LOGO! Web Editor and the LOGO! Access Tool. Check the official LOGO! Software page for the latest service pack number.
Can I borrow a colleague's LOGO! Soft Comfort DVD to install on my own PC?
Yes. The license is tied to the original media being a valid Siemens DVD, not to a specific user. Many machines within a company can be installed from one DVD, provided the number of concurrent users does not exceed the licenses purchased. Always image the DVD to an ISO for safe transport and storage.
My old LOGO! project was saved as a .lsc file from LSC V6 — will V9 open it?
Yes. V9 will prompt to convert .lsc files from V6 / V7 on open and will save the result as .lsc2. The conversion is one-way, so keep the original .lsc file as a backup before converting. For .lld files exported from the on-device editor, import them via Tools → Import rather than File → Open.
Why does the V9 upgrade installer refuse to install on a brand-new PC?
Because the upgrade chain is designed to detect either a prior LOGO! Soft Comfort install or a valid original CD/DVD in a drive. On a clean PC with neither present, the installer blocks the install to enforce the licensing model. The supported workaround is to mount the original ISO (or insert the DVD) and re-launch the upgrade — the install then completes as a full V9 install.