Capacitive vs Resistive Touch Display Technologies - Industrial Monitor Direct

Capacitive vs Resistive Touch Display Technologies

In an automation control system, a touch screen serves as the interface between users and computers. Touch displays, as opposed to keyboards or mouse, offer ease of use and convenient access to transfer information across computers. A preconfigured user interface menu program that navigates across the touch screen to access the system and run particle programs, such CNC controllers or ATMs, is another example.

 

 

Touchscreen are split into two categories:

Resistive Type - When a finger or other stylus generates voltage through the pressure sensors, the resistive type is in operation. The surface of most resistive touch screens is made of a polyester film layer with a conductive metal coating. The liquid crystal display (LCD) is affixed to the bottom portion of the screen, and conductive painted glass plates are used on the top portion. Tiny layers of polyester are used to divide the glass plates. With a controller on each, these glass sheets are positioned along the X, Y, and polyester film, applying a modest voltage in each gradient. The two conducting materials are brought together whenever pressure is applied to the screen, creating an electronic coin that can be seen by the X and Y coordinates.

Because the resistive screen needs two layers of material to react after an impact. Touch mistakes therefore originate from an imbalance in the screen's pressure. Furthermore, the elastic material in the resistive screen, which has lower utilization rates and a shorter lifespan, can only rely on the two materials reacting to the collision.

Capacitive Type – Relies on electrical characteristics of the human body to recognize when and where a person touches a display. Both sides of capacitive touch panels are covered in a scratch-resistant layer and a conductive coating. Its glass is surrounded by electrodes that provide a low-pressure electric field on the outside and an inside conductive layer that offers noise reduction and electromagnetic shielding. Every time the finger contacts the screen, a capacitive coupling occurs with the conductive layer on the outside of the electric field, which allows it to absorb tiny currents. Each electrode must translate its coordinates to the controller after measuring the current from every angle.

It does not need to react on the lower collision and only transmits signals to the screen when the screen is touched.   These touches are messages received to allow the calculation of its coordinates. Hence, capacitive screens can simultaneously support multiple points. The speed however depends on the number of points and the chip being used.

Capacitive Screen and Resistive Screen Comparison

Durability: Winner = Capacitive:
Layers of polyester film are used by the resistive touch screen to identify the essential properties of its coordinates. Due to this film, the screen is extremely vulnerable to scuffs and needs periodic calibrating. However, because it has polyester layers, it is less fragile and less likely to break. The glass' outer layer is used by the capacitive touch screen, giving it some degree of indestructibility. The glass can, however, be broken into pieces. Stains and scratches are less common on this touch screen.


Touch sensitivity: Winner = Capacitive
When operating a resistive touch screen, you need to provide pressure to create contact; you can use your fingers (even when wearing gloves), nails, a stylus, etc. In order to activate the capacitive sensing technology, capacitive touch can have delicate finger contact and can be charged from the bottom of the screen. However, inanimate objects like gloves, nails, etc. will have an invalid data input. Recognition of handwriting is equally challenging.


Precision: Winner = Capacitive
Resistive touch screen’s accuracy of at least 1 single display pixel can be seen when using the stylus. Facilitates handwriting recognition and helps with small operation control.
It is said that capacitive touch screens utilize several pixels, which in effect limits the area of ​​contact by way of the finger. So it is difficult to precisely target icons less than 1cm.


Multi-touch: Winner = Capacitive
Resistive touch screen has no multi-touch capabilities
Capacitive touch screen implements the multi-touch via software. Most of the phone or tablet in today’s market supports multi-touch.

 

Transparency rate: Winner = Capacitive

The screen's picture quality is typically delegated on resistive touch screens. Another issue is the reflection of sunlight. In this case, a capacitive touch screen is appropriate. low sunlight reflection and no image degradation.

 

Cleaning: Winner = Capacitive

A stylus, fingers, or fingernails can be used to interact with resistive touch displays. The issue is that using these techniques makes it simple to leave bacteria, grease, and fingerprints on the screen. making cleaning quite difficult.

Even if a whole finger can be used to contact a capacitive touch screen, its exterior glass is easier to clean.

 

How to identify the type of screens you are using

If the screen reacts in any way, it may be a resistive or an infrared screen. Use your fingernails, not your skin, to gently press on the screen. In this situation, lightly push the screen with two fingernails at two distinct locations at the same time. This device uses infrared technology if the cursor passes beneath any fingernail, but if it moves between two fingernails, the screen is a resistive type touch screen. The next thing you would do is placing two fingers on the screen if the device did not respond to the nails.

Due to their affordability, resistive type screens have historically been the most popular. On the other hand, a growing trend in the industry is the capacitive screen requirement. Its appeal is fueled in part by its superior performance, reliability, adaptability, and simplicity of usage.

Touch Screens are widely used in today’s day to day living.  Tourist kiosks, ATMs, point of sale terminals, industrial control systems, and phones are just some examples of things that utilize the touch screen function.  To date, this market has now ballooned to about over a Billion U.S. dollars. Since this technology has been proven to be user friendly, durable, and cost-effective, the market has no limits.

Back to blog

Leave a comment

Please note, comments need to be approved before they are published.