IMDTouch field guide
The operator interface.
Select, install and troubleshoot a touch display at the machine. Read the field notes or compare an industrial monitor for your existing PC.
Read the field notes →Touchscreen selection →
IMD / PRODUCT FILMS
Hardware, in its element.
The operator interface. Installed.
A closer look at the panel, the control cabinet, and the interface your operators use.
Rendered IMD product demonstrations.

Touchscreen selection
Compare touch and brightness options for a display connected to an existing PC.
Q-Series 15.6-inch industrial touch monitor
Hardware for HMI and touch projects
Panel PCs, touchscreen monitors, fanless mini PCs and stainless enclosures, configured to the job at Industrial Monitor Direct.
Latest articles
Explainer
LatestWhat running an HMI project runtime on a PC without the panel takes
A Pro-face panel project runs on a PC two documented ways: GP-Pro EX simulation on the engineering PC, or the licensed Pro-face PC runtime in its temporary demonstration mode. Both replace only the panel; a physical S7-300 reached over Ethernet stays the confirmed PLC partner, and a connection to WinAC or a Siemens simulator remains unconfirmed.
Troubleshooting
Why one WinCC redundant server freezes trends on insufficient memory
Server 2 freezes because its SQL Server max server memory is left at the factory default of 2147483647 MB, which caps nothing, so SQL growth exhausts Windows commit and the event log reports insufficient system memory. Set both redundant servers to the same measured budget — Server 1 already proves the project runs at its 2048 MB setting — match the archive segment configuration, and verify commit headroom stays open through a full freeze.
How-to
MP270 analog trend curve setup in ProTool and WinCC flexible
A linear trend on an MP270 needs three pieces: the S7 tag carrying the raw analog word, an HMI REAL tag scaled from it, and a trend view with a sampling cycle. This article walks the ProTool, WinCC flexible 2008 and RT Professional paths with the scaling arithmetic worked out.
Troubleshooting
Why an invisible HMI button shows a focus edge in runtime
The visible edge around an invisible button is the panel's runtime focus indicator, drawn at the width set on each button object; it is not the invisible fill or border leaking through. Rebuilding the outlined button only moves focus to a neighbor with the same nonzero setting. Set the focus width property to 0 on every invisible button in the group, then exercise navigation, activation and screen re-entry to confirm the edge is gone.
Comparison
Which stream format lets an HMI panel show an IP camera view
An HMI panel shows an IP camera only when the camera's output matches a display object the runtime can render. The cyclically refreshed JPEG snapshot URL is the lowest-risk match; MJPEG and RTSP with H.264 work only where the runtime documents a camera or media object with those codecs; a proprietary SDK control needs an open Windows runtime. On Comfort Panels the documented object is the Camera view object with MJPEG, H.264 or MPEG4.
Checklist
Custom HMI maintainability checklist for plant applications
A custom WPF HMI is a maintainable replacement for a legacy VB6 system only when five handover checks pass: a clean build from documentation, color reserved for abnormal states, a written PLC data contract on non-optimized data blocks, big-endian decoding inside one communications service, and a second trained maintainer. Each check below carries its pass condition and the decision when it fails.
How-to
WinCC flexible 2008 with a Mitsubishi Q PLC connection
WinCC flexible 2008 can run as a PC-based HMI against a Mitsubishi Q-series PLC. Confirm the PC runtime target, take the driver and interface combination from chapter 5 of the WinCC flexible 2008 Communication Part 2 manual and the installed online help, then match the PLC port, the PC settings and the cable to that driver. Prove the link with one read-only tag before building any screens.
Troubleshooting
Why a WinCC Flexible Excel Report Script Overwrites Its Data
The script writes Date(), Time() and a SmartTags value into fixed cells A2, B2 and B4, then saves the same workbook, so every trigger replaces the previous report instead of appending a row. A missing or stale report traces to one of three separate failures: tag acquisition, Excel COM automation or file access on the runtime PC.
How-to
TP700 Comfort SD card access through the web server HTML pages
TIA Portal over a TS Adapter IE is not the documented route to the card's files; the integrated web server of the Comfort panel is. Enable the HTML pages option, define a web-server account at the panel itself under Control Panel, WinCC Internet Settings, Web Server, and log in from a browser.
How-to
Show operator changes in a WinCC V7.0 Runtime audit screen
WinCC V7.0 shows operator changes to ordinary tags with no extra ActiveX control: copy the table view from the system alarm operation page into a PDL and enable the Operator message property on each tag that must report. Login and logout appear once system messages are on in Alarm Logging. Only User Archive changes need the Audit Viewer 7.2 add-on and its configured audit database.
Troubleshooting
Why WinCC Flexible 2008 SP5 runtime closes without a message
A runtime that opens and closes without a message 10 to 20 seconds after launch is a startup-path termination, not a license fault. Record the exact Windows 10 build with winver, install the Update (Hotfix) for WinCC flexible 2008 Service Pack 5 delivered at the end of Update 2, and correct the Project ID area pointer in the connections editor. The msjet40 archive failure is a symptom branch; rebuilt MDB files hold about a day, then the exit returns.
Troubleshooting
Why WinCC Runtime Advanced shows no data through a CP343-1 Lean
STEP 7 goes online through the CP343-1 Lean, but WinCC Runtime Advanced opens with no tag update and no error banner, because the S7 connection was given the CP's slot number. The CP cannot service an HMI read; the CPU-side endpoint lives in the CPU. Enter the CP's IP address with rack 0 and slot 2 — the CPU 316-2 DP's slot in a standard S7-300 central rack — and no FC5 or FC6 call is needed in the PLC program.