IMDTouch field guide
The operator interface.
Select, install and troubleshoot a touch display at the machine. Read the field notes or compare an industrial monitor for your existing PC.
Read the field notes →Touchscreen selection →
IMD / PRODUCT FILMS
Hardware, in its element.
The operator interface. Installed.
A closer look at the panel, the control cabinet, and the interface your operators use.
Rendered IMD product demonstrations.

Touchscreen selection
Compare touch and brightness options for a display connected to an existing PC.
Q-Series 15.6-inch industrial touch monitor
Hardware for HMI and touch projects
Panel PCs, touchscreen monitors, fanless mini PCs and stainless enclosures, configured to the job at Industrial Monitor Direct.
Latest articles
Troubleshooting
LatestWhy a WinCC Flexible 2008 TrendView Shows No Grid Lines
The 2008 TrendView has no grid property: it draws axis labels only and renders above every screen layer at runtime, so drawn line objects vanish and the WinCC trend ActiveX controls fail to compile or start. Keep the standard TrendView with its axis labels, or move the trend to a platform that documents grid settings.

How-to
WinCC Unified HMIRuntime.FileSystem.Browse for file lists
HMIRuntime.FileSystem.Browse() lists the entries of a WinCC Unified panel folder and IsDirectory() sorts folders from files; take the display name from the text after the last slash. Trigger any file write from a screen object: Task Scheduler tasks run as user scs, which has no write access to the industrial home folder, so scheduled CSV writes do nothing.

Troubleshooting
Why a LOGO! 9 touch screen misses presses when calibration is accurate
Accurate touch location with missed presses is a registration fault, not an alignment fault, so recalibrating the LOGO! 9 changes nothing; the resistive display needs firm pressure through a small contact point: run a press tally with a fingertip and a firm passive stylus, and if the stylus round is clean, commission the unit with the stylus. If both rounds miss, the unit's registration is faulty and it goes back to the vendor.

Troubleshooting
Why the System Diagnostics View stays empty on a Comfort panel
The System Diagnostics View is empty with four greyed-out buttons when the compiled PLC and HMI projects on the equipment do not match the edited configuration. Recompile hardware and software in both projects and download to both the PLC and the panel; the diagnostic messages then appear, including faults from third-party PROFINET devices.

Troubleshooting
WinCC Unified PC Runtime firewall blocks TIA Portal download
When a TIA Portal V21 download to a WinCC Unified PC Runtime server works only with the firewall off, the installer's firewall exceptions are missing. Run the Security Controller installed with the runtime and reapply its security settings, then compare the server's inbound rules against the port list in the WinCC Unified readme's Security information section.

Explainer
Why clearing Zoom allow does not stop WinCC Unified panning
In WinCC Unified PC Runtime V20, a screen that does not fit its screen window always stays pannable, and the Zoom - allow property controls only Unified's own zoom. Clearing it at design time or from the screen's load event leaves the geometry untouched, so a script-cropped window cannot hide privileged settings. Keep each restricted screen small enough to fit and load privileged settings only after the privilege check passes.

Troubleshooting
Why the Transfer entry disappears from WinCC flexible 2008
A Start Center without its Transfer entry has lost part of its action registration, usually after an interrupted update. Right-click the Start Center icon in the Windows notification area, run Reset SIMATIC WinCC flexible (about 10 to 30 seconds) and reopen the tool; Transfer returns. If the reset entry is greyed out, the installation record is damaged: re-run the installed service pack's setup as an update, then reset.

Explainer
Why WinCC Flexible cannot acquire 1000 samples per second
No. The fastest practical acquisition cycle for a WinCC Flexible tag is 100 ms, so the runtime can present a 1000 samples/s stream but never capture it. The wireless DAQ must timestamp and buffer every sample on its own clock, and the panel trends a display representation or a transferred trend buffer within the delay you already accepted.

Troubleshooting
Why an Edge app writes no value to a Unified Comfort tag
The shown code never issues a runtime write: it assigns a local JavaScript variable, compares a property the returned tag object does not carry, and prints to the developer console. Prove the connection on a PC runtime, select the tag by its returned name property, submit the string "19" through the documented OpenPipe write, and confirm it with a runtime readback.

Troubleshooting
Why a KTP700 Sm@rtServer drops its SSL handshake after days
Both errors mean the KTP700's Sm@rtServer session died while the panel kept running: the remote path to the default VNC port aged out behind the cellular router. Move the Sm@rtServer to an unused port such as 5909 on the panel and in the router's forward, install the latest Basic Panel image, and treat remote sessions as short maintenance windows rather than permanent viewers.

Troubleshooting
Backing up an MP277 by MPI when WinAC MP 2008 will not install
Take the backup with ProSave over Ethernet from the Windows 10 PC: it needs no WinAC MP package, no PCS7 and no MPI adapter. The MPI route fails there because WinAC MP 2008 v4.1.1 runs only on Windows XP SP3 and the adapter's USB passthrough freezes an XP virtual machine, so MPI programming moves to a physical XP machine with the PC Adapter set to 187.5 kbps.

Comparison
WinCC Unified or PCS neo: what the difference decides
WinCC Unified is an HMI/SCADA visualization layer you connect to controllers you have already chosen; PCS neo is a complete process control system that includes the control level and its engineering. Decide by what the purchase must deliver — supervisory visualization or a whole process system — before comparing HTML5 faceplates or performance, because similar screens prove presentation only.