IMDTouch field guide
The operator interface.
Select, install and troubleshoot a touch display at the machine. Read the field notes or compare an industrial monitor for your existing PC.
Read the field notes →Touchscreen selection →
IMD / PRODUCT FILMS
Hardware, in its element.
The operator interface. Installed.
A closer look at the panel, the control cabinet, and the interface your operators use.
Rendered IMD product demonstrations.
Touchscreen selection
Compare touch and brightness options for a display connected to an existing PC.
Q-Series 15.6-inch industrial touch monitor
Hardware for HMI and touch projects
Panel PCs, touchscreen monitors, fanless mini PCs and stainless enclosures, configured to the job at Industrial Monitor Direct.
Latest articles
Explainer
LatestWhy a TP170B Mono backup cannot move to a newer panel
A TP170B Mono runtime backup restores only to another TP170B Mono and cannot be retargeted to a successor panel. Moving the application to a replacement is an engineering job: open the editable project, the file with the .hmi extension, in WinCC flexible and change the device type to a target that version supports. Establish which file you hold before ordering hardware.
Explainer
Why WinCC flexible shows only Tahoma in a panel project
A WinCC flexible panel project offers only the fonts its panel firmware can render, and the default language family is why Tahoma is the one face you see. The language-and-font editor exposes two additional language families that change character coverage; fonts installed on the engineering PC never reach the panel. Boxes or blanks mean missing glyphs, so switch the family rather than the size.
Troubleshooting
Why your HMI cannot read PLC tags without a communication shortcut
An HMI reads a PLC tag only through the controller communication shortcut defined in its own engineering tool. Create that shortcut (RSLinx Enterprise, today FactoryTalk Linx) in the HMI project, then make the tag reference's shortcut name match it exactly. Adding the panel to the controller's I/O tree or finding the panel in a discovery browser does not create the tag path.
Explainer
Why no WinCC version is bug-free and which one to pick
No WinCC version is bug-free: every V7 line has shipped corrections after release, and the claim that one release is better carries no test behind it. Choose the exact release and update level that the vendor's compatibility documentation covers for your operating system, drivers and license, then open and run a converted project copy on a bench before anything touches the production station.
Explainer
Where an MP377 Panel IP Address Actually Lives
WinCC flexible does not expose the MP377 panel's own network address as a tag. The active address lives in the panel Control Panel network settings, the project or backup holds only the engineered value, and any on-screen address is a configured label, not a live readback.
How-to
What a C-more CM5 9.02 Update Changes for Old Projects
C-more CM5 V9.02 is a maintenance release that converts EA9 v6.80 and CM5 v8.26 projects. Treat the update as a conversion: archive the original source, work on a copy, and retest screens, communications and alarms before any panel download.
Troubleshooting
Why a WinCC Professional LREAL field shows 0.0
A WinCC Professional I/O field that shows 0.0 while the PLC data block holds a correct LREAL is losing the value between controller and screen, usually at the HMI tag. Read the LREAL in a watch table, monitor the tag next, and check the field assignment and format last. If direct display still fails, keep the LREAL for processing and derive a separate REAL display tag, such as watt-hours divided by 1000 shown as kilowatt-hours.
Troubleshooting
When WinCC OPC UA browsing works but runtime gets no values
Successful tag browsing and installed certificates prove only that WinCC reached the bridge's address space. Commission the link as four boundaries — upstream data into the bridge, the OPC UA session, the tag mapping, runtime updates — with one known test item, and stop at the first boundary that fails; it names the fix.
Troubleshooting
What WinCC Runtime Advanced needs on an S7-1200 HMI PC
A PC that only operates an S7-1200 needs one software package: WinCC Runtime Advanced, installed from the dedicated runtime setup, plus a compiled project and a working Ethernet path. SIMATIC NET is not required for this HMI connection; it enters only when the same PC also runs a Siemens software controller. The example station runs V13 SP1 Update 9.
Explainer
Why WinCC library symbols rotate only in 90 degree steps
In WinCC 7.x, a library symbol exposes only the predefined 0, 90, 180 and 270 degree rotation positions, and the line object is the only graphic that accepts a freely defined angle. For 65 or 120 degrees, prepare one rotated image per position and switch them with an internal variable.
Troubleshooting
Why WinCC flexible 2008 fonts look oversized on another PC
Oversized text and shifted buttons in WinCC flexible 2008 on one computer come from the Windows letter-size (display scaling) setting, not the project. A PC set to 125% draws every text and control 1.25 times larger than the PC the project came from. Set Windows letter size to 100% and reopen the project.
Troubleshooting
Obsolete Panel PC Driver and Restore Media Recovery Routes
A missing device driver and a failed operating-system restore are separate faults on an obsolete panel PC. Read the nameplate order number and the boot state first, then request the driver package, its installation instructions and any replacement recovery media through the manufacturer's support channel for that exact unit — general download sites carry no license entitlement and unverified images.