IMDTouch field guide
The operator interface.
Select, install and troubleshoot a touch display at the machine. Read the field notes or compare an industrial monitor for your existing PC.
Read the field notes →Touchscreen selection →
IMD / PRODUCT FILMS
Hardware, in its element.
The operator interface. Installed.
A closer look at the panel, the control cabinet, and the interface your operators use.
Rendered IMD product demonstrations.
Touchscreen selection
Compare touch and brightness options for a display connected to an existing PC.
Q-Series 15.6-inch industrial touch monitor
Hardware for HMI and touch projects
Panel PCs, touchscreen monitors, fanless mini PCs and stainless enclosures, configured to the job at Industrial Monitor Direct.
Latest articles
Troubleshooting
LatestWhy a Unified Comfort panel SendEmail needs new runtime values
A dead SendEmail button with no movement on the Processing status tag is usually the panel's retained SMTP record, not SMTP itself. Start a full download, clear the keep-existing SMTP option in the Load preview Runtime values section, and expect roughly five minutes between sends from the same button.
Troubleshooting
Why an Edge app does not autostart on a Unified Comfort Panel
An Industrial Edge app on a Unified Comfort Panel starts on its own only if its containers carry a restart policy such as unless-stopped. Installation alone does not set one, and an HMI Runtime button can open an app's interface or send it a command, but it cannot start a stopped container.
Explainer
Why a WinCC Flexible project on a server needs the tool on your PC
The project files can live on the server, but the engineering tool cannot: WinCC Flexible must be installed on the PC you sit at, and Windows Server 2003 cannot host it. In the reported case, Windows 7 Professional and Windows XP Professional clients running WinCC Flexible SP3 opened the server-hosted projects without the message, while matching users and SIMATIC group memberships changed nothing.
Troubleshooting
Why a WinCC 7.3 client reports no start screen
A WinCC 7.3 client that reports no start screen has failed to resolve its server-qualified start picture, usually Server::start.pdl. Confirm the launch chain first: SIMATIC Shell shows every station, the client is in the server project's computer list, and the logon account is known on both stations with a non-empty password. When all of that passes, install WinCC 7.3 Update 7; that is what restored the client in the documented case.
Troubleshooting
Keep using your WinCC Comfort V15 license with TIA Portal V14
You do not need to buy any new license. Install the WinCC Comfort V14 engineering component beside your TIA Portal V14 Basic installation; the WinCC Comfort V15 floating license authorizes V14 and V15. The 21-day STEP 7 Professional V15 trial only covers temporary PLC editing in V15, not your Comfort Panel HMI work.
How-to
Configuring WinCC Unified user administration and function rights
Build WinCC Unified protection centrally in the project tree under Security settings → Users and roles: create roles with function rights, give users their Assigned roles, and set each screen object's Properties → Security → Authorization. On the first download, clear Keep current user administration data in runtime so a locked or stale user table on the panel does not survive the load; leave it ticked only when panel-side passwords must survive.
Troubleshooting
Why the printer driver is missing in ProSave for a TP1500 Comfort
The driver is missing because ProSave filters transferable options by the selected device type: a driver offered under TP700 Comfort but not TP1500 Comfort applies to the first target only. Keep the TP1500 Comfort selected, check the package release notes against the panel image and software versions, transfer through the ProSave Options tab, and use a printer the vendor lists as tested.
Explainer
Which software configures a KP1200 Comfort panel
A SIMATIC HMI KP1200 Comfort is configured with WinCC Comfort inside TIA Portal, from V11 onward; WinCC flexible 2008 SP3 has no device support for it, so nothing can be created or transferred from flexible. Pick the WinCC Comfort edition or higher, align the project's device version with the panel image, and transfer over the panel's PROFINET interface.
How-to
Transfer a WinCC flexible project to an MP277 via S7 routing
Yes, the engineering PC reaches the CPU 315-2 PN/DP over Ethernet, the CPU forwards the WinCC flexible transfer onto its MPI subnet, and the MP277 receives it at its MPI node address. That takes the CPU's routing configuration compiled and loaded, the panel configured on the MPI subnet, transfer enabled on the panel's MPI/PROFIBUS channel, and the PC's online access bound to its Ethernet adapter. Routing never targets the panel's Ethernet channel.
Troubleshooting
Why Your HMI Runtime Shows a Demo Mode Message
A demo mode banner means an enabled runtime option on the panel has no valid license: install that option's license key or disable the option. The SD card recording failure is a separate storage condition — measure archive growth and fix retention or media instead of clearing records again.
Troubleshooting
Why a Copied Project Reports a User Rights Error
The message reports missing user rights, but on a project copied out of its engineering folder the real fault is project state: the copy still carries the identifiers of an integrated project, so the access-protection check fails on open. Verify SIMATIC HMI group membership first; if the account is in the group, stop chasing Windows permissions. Recover the project through the engineering tool, the Project Duplicator or the documented deintegration procedure, never by editing the configuration database.
Selection guide
Which HMI replaces a K-TP 178 micro on an S7-200CN PLC
The S7-200CN stays in service: it runs the same PPI protocol on its RS-485 port as every S7-200, so the discontinued K-TP 178 micro can be replaced by any HMI with a documented S7-200 PPI driver. Select on the driver, the serial port, V/M/I/Q addressing and your screen functions, and match baud rate and station address at both ends before commissioning.