Panel PCs and displays
Panel PCs, industrial monitors, video interfaces, mounting and sealing.
Latest articles
Explainer
What HMI LCD means and how to specify one
An HMI LCD is the liquid-crystal display at the front of an operator interface. The LCD label names the image-forming technology and settles nothing else: legibility comes from resolution and font height at the real viewing distance, touch is a separate sensor to verify per model, and temperature, sealing and vibration limits are documented product specs.
Troubleshooting
Fixing a Cape Display That Shows Only a Bright Vertical Line
Backlight that adjusts from 0 to 100 with only a bright vertical line means the panel is lit but the pixel path is misprogrammed: BB-BONE-4D7C-01-00A1.dts targets am33xx, and the BeagleBone AI is am572x. Rebuild the overlay from BBAI-4D4C-00A1.dts on the v4.19.x-ti-overlays branch and the splash logo returns; any remaining color or geometry fault is a driver timing or colorspace review item, not dead hardware.
Selection guide
When a Desktop PC Beats an Industrial PC for Data Acquisition
No. Low-frequency waveform acquisition with a plug-in DAQ card, a bench multimeter and a USB interface does not need an industrial computer in a temperature-controlled, low-volume production area — a desktop that meets its published limits does the job. Move up when the ambient rating, contamination, 24/7 uptime or written multi-year availability demands it, and prove the station with a full-length run.
Selection guide
How to Select an Industrial PC for LabVIEW ATE Development
Run 32-bit LabVIEW unless one buffer or array cannot live under the 4 GB address space of a 32-bit process and every toolkit and driver you need exists in 64-bit form; bitness alone adds no speed to ATE code. Specify the industrial PC from a counted inventory of the interfaces the target testers use, from a supplier who will hold the configuration unchanged.
Selection guide
Selecting a thin-bezel industrial HMI display for a cutout
A bezel under 3 mm puts the cutout within about 6 mm per axis of the active display area, so the decision rests on the model's own cutout drawing, front-only IP66 sealing with a separately rated rear enclosure, and whether the station needs a panel PC or a standalone monitor.
Troubleshooting
Fixing Press-and-Hold Right-Click in HMI Apps on a Touch Panel
If press-and-hold opens the right-click menu in Notepad but drags a control inside your HMI or CNC application, the touch panel, its driver and the Windows gesture setting are proven good — the application is capturing the touch as a drag. The fix is a correction to that application from its vendor, not a driver change; in the documented case, a patched KMotionCNC.exe for KMotion435c resolved it.
Selection guide
Selecting a Touch Panel That Can Run Ignition and MySQL
Only a panel PC running Windows or Linux can host the Ignition gateway and MySQL; an HTML5 web HMI is a locked browser that displays native HTML5 views and nothing more. Put the gateway and database on a separate computer and make the panel a swappable client — the memory math below shows why the all-in-one panel rarely fits both.
How-to
Connecting a bare TFT panel to a different controller board
No, not from the connector alone. A flat cable that mates can still land a supply rail or the LED string on a logic pin, so decide the substitution on paper first. Verify flex pinout and orientation, supply rails and power-up order, the LED string against the backlight driver, native resolution and pixel timing, and touch wiring; connect only when every gate passes.
Checklist
Verifying Windows 10 IoT is installed and activated on a panel PC
Verify that the panel PC boots, matches the Windows IoT edition ordered and reports its activation status. An OEM unit must be enabled for activation before shipment. Activation can remain deferred on an offline device, so confirm what the order requires before accepting it.
How-to
Install and persist HMI software on a Windows CE touch panel
Install the application to the panel's flash storage — SD card or USB mass storage — through ActiveSync or Windows Mobile Device Center, never to the RAM object store, because RAM-resident files on Windows CE 5.0 panels are lost when power drops. Then set a static IP, drop a shortcut in `\Windows\Startup`, and prove it with a full cold-boot test.
Checklist
Qualifying a SINUMERIK 840D operator PC retrofit before you buy
Do not order an 840D operator PC retrofit until you hold one written line from the vendor naming the HMI release and operating-system image released for your installed NC software version. The retrofit replaces only the operator-interface PC; the NC, PLC and drives stay. Back up everything, image the old disk, and gate acceptance on five clean production programs.
Troubleshooting
Fixing a Panel PC Virtual Memory Warning in Web HMIs
The warning means the browser is holding the main HMI page and the embedded iframe page at the same time and Windows commit charge has reached its limit. Replace the iframe with a button that navigates to the dashboard page, so only one page stays in RAM. A larger paging file or another browser does not add RAM or lift the operating system's browser-version ceiling.