Knowledge Base
Earlier articles
How-to
WinCC V13 SP1 PDF viewer object on Runtime Advanced and Comfort Panels
WinCC V13 SP1 adds a standard PDF viewer object for WinCC Runtime Advanced, Comfort Panels and second-generation Mobile Panels, with the HMI at version V13.0.1.0 or higher. Place the object from the toolbox, enter the PDF path and file name, and wire buttons to the PDF* functions such as PDFGotoPage and PDFZoomIn — no script is required.
Troubleshooting
Why an HMI VNC Session Shows a Black Screen but Input Works
When a VNC session to an HMI authenticates, stays black, and clicks at known button positions still actuate the physical panel, the remote-control path is healthy and only the framebuffer-update path is failing. Compare the local screen, confirm authentication, run one observed input test, then take the display-delivery branch: check the access route and client, and get the panel firmware or engineering-software revision that restores screen delivery. Leave tags, drivers and cabling alone.
Troubleshooting
Why an HMI shows communication error popup 40001 on the bench
The Communication Information 40001 window is the panel's system prompt for failed driver polls, so it repeats on any bench run with no PLC connected. Disable Show System Prompt under GlobalSet, System Setting in DTools Pro 1.10, compile and download, and the popup stops while screens and macros keep working. For anything that ships, keep the prompt or handle the link status with your own alarm logic, because a suppressed popup silences a real lost link.
Troubleshooting
Why ProTool Lite Cannot Open a TP270 Project It Does Not Support
A TP270 project that will not open in ProTool is blocked by the editor edition: ProTool Lite does not support the TP270 target. Installing the full ProTool edition, reported working at version 6.0, opens the project before any PLC or transfer diagnosis is needed.
Troubleshooting
Why a WinCC flexible 2008 I/O field rejects fractional timer values
In WinCC flexible 2008 SP3 an I/O field formats a raw word; it does not convert a typed 2.5 or 0.1 into an S5Time duration, which is a time-base code plus three BCD digits. Connect the field to an integer preset in tenths of a second, encode S5Time in the PLC, and verify by reading the word back.
How-to
Keyboard-only WinCC 7.0 Runtime operation needs TAB Sequence
WinCC 7.0 Runtime runs without a mouse once each screen has a TAB Sequence configured in Graphics Designer: the object types are enabled for tabbing, the focus order is set across the setpoint fields and command buttons, and the sequence is tested online. Arrow-key behavior identical to an older HMI is not part of that guarantee and must be verified separately per screen.
Explainer
Why replacing an HMI does not change the PLC program
An HMI is only a client: it reads and writes the same controller addresses over the same protocol and port, so a replacement panel needs matching tags, connection settings and data types — not PLC edits. The program changes only where the old panel's configuration defined PLC-side coordination areas: a time-synchronization mailbox, a screen-number word, a heartbeat bit or an alarm bit array. Audit those, and everything else happens in the HMI project.
How-to
PLC triggered user login by alias on a unified panel
From V19 Update 2, SetzeLokalenBenutzer (SetLocalUser in the English documentation) logs the local WinCC Unified user in from an alias string a PLC supplies; PC Runtime needs Login mit RFID aktivieren selected first, and web clients are excluded. Unified tags have no value-change event, so trigger a script dynamized on an unused property of an object in the main screen window, guard it against an empty alias, and let the function clear the tag after each login.
Explainer
Third-party touchscreen panels and the runtime target that decides
An embedded-panel project only ever downloads to the panels listed for that engineering tool, so a non-vendor touchscreen cannot take its place. A third-party touchscreen works only in a PC-based architecture, where a licensed runtime on the host passes the release's documented OS, resource and touch-driver checks. Pick the architecture first, then qualify the hardware.
Troubleshooting
Why the 840D sl HMI package will not install on Windows 7 x64
The SINUMERIK HMI configuration package for WinCC flexible 2008 fails on Windows 7 x64 because setup's operating-system check finds a 64-bit host and the package's documented engineering environment is 32-bit Windows XP. Compatibility mode and administrator rights cannot pass that gate. The supported fix is a licensed 32-bit XP station, usually a virtual machine, with base WinCC flexible 2008 installed first.
Troubleshooting
WinCC Professional runtime shows S7-1200 disconnected
A WinCC Professional V13 runtime that lists the S7-1200 channel as disconnected has two documented places to look: the S7ONLINE access point mapping TCPIP.1 to the physical port that carries the PLC network, and the S7RTM is installed property on the PC system in the TIA Portal device configuration. In the reported IPC647D PN/IE case the channel stayed disconnected even after the V13 SP1 update, so clearing the property and rechecking the mapping come first.
Troubleshooting
Why a WinCC server IP change freezes all HMI clients
Treat the synchronized freeze as a server-side fault with two leads: pin the process server to its fixed address instead of dynamic addressing, and find any add-on such as OPC software running on a demonstration license whose documented runtime limit matches the interval between freezes. Rebooting only resets the running session. Run the server without its SCADA software to rule the machine itself in or out.