Troubleshooting
Why a Panel PC 670 touchscreen fails with UPDD installed
Short answer
A Panel PC 670 touchscreen can stay dead with the UPDD package installed and the USB device visible in Device Manager, because installing the package and registering the controller with UPDD are two separate steps. Open Start > Programs > UPDD > Settings: an empty controller list is the fault. Reinstall the package matched to the panel's MLFB number and confirm the controller appears in that list before you calibrate anything.

On this page
A Panel PC 670 can show a dead touchscreen with the UPDD package installed from the CD and the USB device sitting in Device Manager, because installing the package and registering the touch controller with it are two separate steps. The check that decides the fault is the controller list in the UPDD settings utility, opened through Start > Programs > UPDD > Settings. If that list is empty, UPDD has no controller to read and the pointer will never move, whatever Device Manager reports. Read the MLFB number on the unit, install the driver package matched to it, and confirm the controller appears in the list before you calibrate anything.
Device Manager proves enumeration, not the binding #
Device Manager answers one question: did Windows detect the USB hardware and hang an entry on it. That is enumeration. It says nothing about UPDD, the universal pointer device driver package that reads the touch controller and moves the pointer on these units. UPDD works from its own controller list, and a package can copy its files, create its program group under Programs, and finish its installer while that list stays empty. The screen is then exactly as dead as with no driver at all.
Calibration sits downstream of all this: it corrects the coordinates of input that already arrives, so running it against an unregistered controller changes nothing.
The check that decides it: the controller list #
Open Start > Programs > UPDD > Settings and read the controller list before you reinstall anything. The observed combination tells you where the fault lives:
| What you observe | What it means | Do this next |
|---|---|---|
| No touch device in Device Manager, UPDD Settings list empty | The controller is not enumerating: a hardware problem, not a driver problem | Isolate power, open the unit per its maintenance instructions, inspect the touch controller connection |
| Device present in Device Manager, UPDD Settings list empty | Package installed, controller never registered: the classic CD-install failure | Reinstall the package matched to the MLFB number; the controller must appear in the list |
| Controller listed in UPDD Settings, pointer still dead | Registration exists but no input data arrives | Use the input test or status display the utility provides; no raw hits means the controller or its cable |
| Pointer moves but lands off target | Input arrives with wrong coordinates | Calibrate at the resolution the machine actually runs |
| Pointer fine on the desktop, operator screen ignores touch | The input path is healthy | Debug the runtime application, not the driver |
Read the identifiers before you touch the driver #
The driver package is selected by hardware identity, not by the model name alone, so record three things first:
- The MLFB number from the label behind the panel; the driver download entry for the Panel PC 670 on the Siemens support portal selects drivers by it.
- The full operating-system name and version from System properties. A unit in this condition typically runs Windows 2000, and the package must explicitly cover that system.
- The touchscreen type number, from the unit's documentation or the controller label inside the panel. The touch variants of the 670 came as 12-inch and 15-inch units, and the controller type, not the screen size, picks the controller definition.
Reinstall in the documented order #
- Work in a maintenance window with a keyboard and a USB mouse attached, because you may finish with touch still dead; keeping a machine operable that way is covered in using a mouse and VNC when an HMI touchscreen fails.
- Record the current state first: the Device Manager status text, the UPDD controller list, and any error message word for word.
- Read the MLFB number and take the matching package from the driver download entry for the Panel PC 670. Do not substitute an unrelated USB touch driver.
- Remove the current UPDD installation the way its documentation prescribes, restart, install the matched package, restart again. Copying files from the CD is not an installation.
- Reopen the UPDD settings utility and confirm the controller entry is present. If it is, drag the pointer by touch to all four corners of the desktop.
- If it tracks but sits off target, calibrate at the resolution the runtime actually uses; the coordinate mapping is the same one you fix when you calibrate a resistive touch overlay in its USB controller.
When the controller still will not register #
If the matched package installs, the restarts are done, and the UPDD list is still empty, the controller is not answering on its USB connection and no driver version will change that. Isolate power, open the unit per its maintenance instructions, and reseat the touch controller connection; do not treat an unidentified internal header as a spare USB port. When the controller or its board is dead and the unit's age argues against board-level repair, industrial panel PCs take over the station and run the same PC-based HMI runtime.
Prove it before the machine runs #
- The controller is listed in the UPDD settings, with no error on the device in Device Manager.
- The pointer reaches all four corners of the desktop by touch.
- The calibration holds after one full power cycle; a map that drifts back was not stored.
- The smallest buttons on the operator screen accept a press at their corners.
Questions asked
The pointer jumps to a screen edge by itself. Is that the same fault?
No. A controller missing from the UPDD list produces no pointer motion at all, so a cursor that moves on its own is a different fault class, tied to coordinates or interference. The manufacturer's support portal carries a separate entry covering cursor-at-edge behavior on touch versions of the Panel PC 670 and 870, and that entry, not a driver reinstall, is the one to work through.
Can a generic USB touchscreen driver stand in for the UPDD package?
No. UPDD registers controllers from definitions matched to the controller type, and the package for this panel is selected by its MLFB number. A driver built for a different controller installs cleanly and then registers nothing, which recreates exactly the dead screen you are fixing. Take the package from the manufacturer's driver download entry for the Panel PC 670 and nowhere else.
Does the calibration survive a resolution change?
No. Calibration maps raw controller coordinates to the pixel grid of one resolution and one orientation, so a display change or a fresh driver install puts you back on an unaligned map. Recalibrate at the resolution the runtime actually uses, and repeat the corner presses after any later change to the display configuration.
Why did this panel need a touch driver from a CD at all?
The Panel PC 670 left the factory with the operating system and its device drivers already installed, so a unit with no working touch driver has usually had the driver removed, the operating system reinstalled, or a replacement computer module fitted with a different image. That history matters: it tells you the original matched package is what to restore, selected by the MLFB number on the label on the rear of the unit.


