Why an .emtp file will not open in EasyBuilder 8000

HMI and touchscreens Published 6 min read By IMDTouch engineering team

Short answer

No conversion exists. An .emtp file is an EasyBuilder Pro project, EasyBuilder 8000 does not open it, and the compatibility between the two tools runs one way, into EasyBuilder Pro. The MT6070iP is programmed from EasyBuilder 8000, so the recovery is an earlier 8000 project copy or a rebuild in 8000, proven on the bench before the rest of the stock is programmed.

On this page
  1. The two tools and the two project formats
  2. EasyBuilder 8000 owns the MT6070iP
  3. Why the conversion runs one way only
  4. The recovery order for the stock
  5. The bench-first count for 50 MT6070iP units
  6. Keep the 8000 source as the master
  7. Questions asked

No. An .emtp file is an EasyBuilder Pro project, EasyBuilder 8000 does not open it, and no converter exists in that direction: the compatibility between the two tools runs one way, from EasyBuilder 8000 into EasyBuilder Pro. An MT6070iP is programmed from EasyBuilder 8000, so a project that survives only as an .emtp saved by EasyBuilder Pro cannot reach those units. The recovery is an earlier EasyBuilder 8000 project copy, or a rebuild of the application in EasyBuilder 8000, proven on the bench before the rest of the stock is programmed. What follows is which tool owns which file, why the reverse conversion does not exist, and the order to work in.

The two tools and the two project formats #

EasyBuilder 8000 and EasyBuilder Pro are separate tools with separate project formats, and the .emtp extension belongs to EasyBuilder Pro. The engineering PC in this case ran EasyBuilder Pro 6.05.01.565 before the update; afterwards, the MT6070iP no longer appears in the supported-model list. Treat that absence as the reported symptom it is, but it fits how the tool is maintained, because every release revises the model list. The release notes for EasyBuilder Pro V6.08.01.622 show the mechanism in the adding direction: that release lists cMT2158X (V2), cMT3152X (V2), MT8052iP and MT8106iP as newly supported models.

A list that moves between releases decides what you can compile, and your own history shows it moving the other way: a model that built under 6.05.01.565 is absent after the update. The situation of an MT6070iP that no longer appears in the model list has its own write-up in fix for an MT6070iP missing from the EasyBuilder Pro model list.

EasyBuilder 8000 owns the MT6070iP #

Commit to this: an MT6070iP project is created and compiled in EasyBuilder 8000. The basis is the model's own documentation: the installation instruction for the MT6070iP and MT8070iP series refers you to the brochure and EasyBuilder 8000 for detailed specifications and operation. The family split is deliberate, because the installation instructions for the MT6000/8000iE series refer to EasyBuilder Pro for the same kind of detail. Each series has the environment its documentation assigns to it, and for the unit on your bench that is EasyBuilder 8000.

So the .emtp on the desk is the wrong kind of object for this job twice over: it belongs to the other tool, and no path turns it into the project this model needs. Whatever older EasyBuilder Pro build once listed the MT6070iP, the project that reaches your units has to be created in EasyBuilder 8000.

Why the conversion runs one way only #

Every documented conversion path runs old to new. A project from the MT500 generation converts into EasyBuilder 8000, as converting an MT500 project to EasyBuilder 8000 shows, and an EasyBuilder 8000 project moves forward into EasyBuilder Pro, with how password security carries from EasyBuilder 8000 to Pro covering what happens to its protections on the way. The EasyBuilder Pro manual adds one more forward path of its own, converting projects from iE, eMT and XE models to cMT and cMT X.

In the reverse direction there is nothing: no export, no save-as, no intermediate format, no released converter. EasyBuilder 8000 has no import that reads an EasyBuilder Pro project, which is exactly why the file will not open. This question has been put to the software's support and answered flatly, that the conversion is impossible, and the engineering position here is the same: stop looking for a converter, because none exists.

Keep one neighbouring failure separate. An .emtp saved by a newer EasyBuilder Pro build is refused by an older build, a version mismatch inside one tool. That error is real but fixable, and resolving EasyBuilder Pro .emtp version mismatch errors deals with it. It also closes the other tempting route: if the updated build has re-saved your project, the older EasyBuilder Pro that still lists the MT6070iP will refuse the file as well. In both tools the arrow points the same way, since a project opens in the build that saved it or in a newer build, never in an older one and never in the other tool.

The recovery order for the stock #

  1. Hunt for a surviving EasyBuilder 8000 copy before building anything: the engineering PC, network shares, backup drives, removable media, and the machines of everyone who touched the project. One intact copy turns the job into validation instead of a rebuild.
  2. If nothing survives, rebuild. Open the .emtp in the EasyBuilder Pro build that reads it and use it as the reference; recreate the screens, objects, address map and PLC driver settings in a new EasyBuilder 8000 project for the MT6070iP. The .emtp stays reference material, because it cannot be compiled for this model in the current builds.
  3. Take the EasyBuilder 8000 installer from Weintek's official download area rather than a mirror, so the installer, manuals and model support come from one source. If the install fails at launch with error 0xc0000005, clear that first with fixing EasyBuilder 8000 error 0xc0000005 at startup.
  4. Prove the recovered or rebuilt project on the bench, then program the remaining units and freeze the verified source.

The bench-first count for 50 MT6070iP units #

Inputs, and where each comes from:

  • Stock on the shelf: about 50 MT6070iP units, from your own count of the units waiting for the standard application.
  • Surviving EasyBuilder 8000 project copies: 0, because the backup was ruined.
  • Usable reference: 1 .emtp file, readable only inside EasyBuilder Pro.
  • Gate: 1 unit must pass a full function check before any other unit is programmed.

The rule, in words: until the bench unit has passed the check, the whole stock is exposed to an unproven project; after the pass, the source is frozen and the stock is programmed from the frozen copy only.

The arithmetic:

  • Units exposed with no gate: 50 units.
  • Units exposed with the gate: 1 unit.
  • Units that wait for the pass: 50 units minus 1 unit = 49 units.

Result: one MT6070iP carries the risk, and 49 units stay untouched until the verdict.

The decision, with its threshold: zero faults on the bench unit, meaning every screen opens, every object responds, and the PLC exchange runs with the real driver settings, releases the remaining 49 units for programming from the frozen copy, archived in a second location. One fault or more stops the run: the damage stays on the bench unit, and the project goes back for a fix before anything else on the shelf is touched.

Keep the 8000 source as the master #

After the recovery, the master for this stock is the EasyBuilder 8000 project, kept on the engineering PC and in an offline location, and re-archived after every change that reaches a unit. The .emtp can stay on disk as reference material for the models EasyBuilder Pro still serves, but it is never again the only copy of anything an MT6070iP runs. EasyBuilder Pro remains the right tool for the families its documentation assigns to it; the point is not to abandon it, but to let each tool own its models and to keep every source where those models can still be built.

Questions asked

Can renaming the .emtp file make EasyBuilder 8000 open it?

No. The extension is only a label; the content is an EasyBuilder Pro project, and EasyBuilder 8000 reads none of it under any name. Renaming changes what the file is called, not what it contains, and there is no import command in EasyBuilder 8000 that accepts the content either way. The only file that helps is a genuine EasyBuilder 8000 project.

Where should the EasyBuilder 8000 installer come from?

From Weintek's official download pages, never from a third-party mirror. The vendor's site carries the software together with the manuals and the release notes, so the installer, the documentation and the supported-model list you verify against come from one source and stay consistent with each other.

Will EasyBuilder Pro still open the old EasyBuilder 8000 projects?

Yes, that is the direction the compatibility runs: the MT8000iP brochure describes EasyBuilder Pro as completely compatible with EasyBuilder 8000. One detail to budget for: the manual's forward conversion into cMT models gives the result the Classic style as its default, so a converted project needs a short restyling pass. Nothing in that relationship runs backward.

The old EasyBuilder Pro build still lists the MT6070iP. Can I keep using it?

You can keep an old build on an offline engineering PC, but it is a dead end. Your update already showed the model leaving the list, and the next reinstall, PC replacement or operating-system update can strand the project a second time. The documented environment for the MT6070iP is EasyBuilder 8000, and rebuilding there once removes the dependency for good.

Keep reading

  • How-to

    Convert an MT500 Project to EasyBuilder 8000 and Resize It

    EasyBuilder 8000 converts an MT500 .eob into a new .mtp project through the Tools menu; the converter selects the terminal with the nearest dimensions, so you must then select the real destination model on the Model tab and work through the resize dialog it triggers. Verify page geometry and live controller data before the panel returns to service.

    HMI and touchscreens

  • Troubleshooting

    Why PanelBuilder 32 Will Not Open Your Uploaded PVA File

    PanelBuilder 32 refuses the .PVA because it is the compiled runtime image for one terminal catalog number, not the editable .PBA project. When versions 2.6 through 3.83 all reject the file, no version fixes it: pull the readable text with a hex editor, keep the file as a clone image for an identical terminal, and rebuild the project from the terminal and the PLC program.

    HMI and touchscreens

  • Troubleshooting

    Why ProTool Lite Cannot Open a TP270 Project It Does Not Support

    A TP270 project that will not open in ProTool is blocked by the editor edition: ProTool Lite does not support the TP270 target. Installing the full ProTool edition, reported working at version 6.0, opens the project before any PLC or transfer diagnosis is needed.

    HMI and touchscreens

Activating a WebIQ Designer trial license for project conversion