Explainer
Why an exclusive device driver is missing from your EasyBuilder Pro
Short answer
A device driver written by an HMI distributor for its own customers ships only inside that distributor's EasyBuilder Pro build. There is no supported procedure to import it into a generic release such as 6.09.01.556, so keep the project on the distributor's software that contains the driver and take upgrade-path questions to the distributor that owns it.
On this page
- Why is the controller missing from the supported-devices list?
- Is there a procedure to import a driver into another EasyBuilder Pro build?
- Can you copy driver files from the distributor build into the generic build?
- Which EasyBuilder Pro version should you run for the project that needs the driver?
- What should you record and ask before any change?
- When does an exclusive driver become a migration problem?
- Questions asked
You are using a distributor's EasyBuilder Pro build because it contains a device driver for a controller the generic release does not list, and now you want to move to a newer release such as 6.09.01.556 without losing that driver. The answer is short: you cannot import it, so you do not move. A driver written by an HMI distributor for its own customers exists only inside that distributor's build of the software, and the supported path is to stay on that build and route upgrade questions to the distributor that owns the driver. This article explains why the driver is absent, what the supported-devices list actually tells you, and how to decide release by release.
Why is the controller missing from the supported-devices list? #
Because the driver was not written by the software manufacturer, it is not on that manufacturer's supported-devices list, and it will not appear there no matter how new a generic release you install. EasyBuilder Pro ships with a large built-in driver library; the manufacturer's own product page describes over 400 PLC drivers covering the major controller families. That library and its published device list cover only the drivers the manufacturer supports. A driver developed by a distributor, such as the Animatics SmartMotor driver developed for one distributor's customers, is a dedicated component of that distributor's software distribution and is intentionally exclusive to its customers. Its absence from the generic list is consistent with that ownership, not a sign that the list is outdated. If your controller is missing for a different reason, such as a driver that exists but is not loaded, the diagnosis in when the HMI software has no driver for your PLC applies instead.
Is there a procedure to import a driver into another EasyBuilder Pro build? #
No supported import procedure exists, and you should treat any workaround you find as unsupported. Drivers in EasyBuilder Pro are compiled into the software release by whoever builds it; they are not plug-in files that a user installs, exports or registers. The distributor that wrote the driver supplies it inside its own EasyBuilder Pro distribution and documents no way to extract it, and the generic release documents no way to add one. There is therefore nothing to import: the release either contains the driver or it does not, and you find out by opening the device list in that release and looking. This is the same class of problem as a model missing from the programming software list, covered in when an HMI model is missing from the programming software: the software you run defines what you can configure, and the fix is to run the software that contains the item, not to inject the item into software that lacks it.
Can you copy driver files from the distributor build into the generic build? #
You can copy files, but the result is unsupported and you should not run a plant on it. Nobody documents which files make up a driver, what registry or project-database entries it needs, or how it is version-matched to the compiler that turns your project into a panel download. A hand-copied driver that half works fails in the worst place: the project compiles, the panel accepts the download, and the connection to the controller drops or misreads addresses in production. The decision: do not attempt a file-level transplant. If someone tells you it worked for them, that is one unverified anecdote, not a compatibility result.
Which EasyBuilder Pro version should you run for the project that needs the driver? #
Run the distributor's build that contains the driver, and stay on it until the distributor gives you a supported path forward. The decision table is short:
| Item | Decision |
|---|---|
| Project that uses the distributor's driver | Keep it on the distributor's EasyBuilder Pro build. |
| Generic release such as 6.09.01.556 | Do not migrate the project to it; it does not contain the driver. |
| File-level driver transplant | Not supported; do not attempt. |
| Upgrade path | Ask the distributor that owns the driver whether its current build supports your controller and panel. |
If a separate problem on the same machine seems to need the newer generic release, such as a driver no-response fault after a version upgrade, first confirm whether the distributor's current build already fixes it; the failure pattern in EasyBuilder Pro V5 to V6 upgrade shows HMI no response is a release-related fault, and the distributor's build is itself a release of the same software. Splitting one project across two builds is not an option: the project file belongs to the build that can compile all of its devices.
What should you record and ask before any change? #
Before anyone touches the working installation, capture four things and then ask the distributor one precise question:
- Record the installed distributor software version exactly as its About window shows it.
- Archive the working project file and the compiled download that is on the panel today.
- Note the panel model and its firmware version.
- Ask the distributor whether its current build supports your controller connection and your panel model, and whether it provides a supported upgrade path.
With that record, the distributor can answer with a version number instead of a guess, and you can verify the answer on a bench copy of the project before the machine is involved. Verify that the project still exposes the device configuration for the controller and communicates with the real hardware; a compiled download that lists the device proves the build contains the driver, and a live read from the controller proves it works.
When does an exclusive driver become a migration problem? #
It becomes a migration problem when the controller, the panel or the distributor's software reaches end of support while the generic software keeps moving. Plan for that before it lands. The exclusive driver ties the project to one software channel, so the long-term options are: keep the controller and stay on the distributor's supported build for as long as it exists; replace the controller with one that the generic release supports, which frees the project to move to the generic software; or keep the old installation frozen on an isolated engineering PC and treat it as a maintained legacy configuration. Choose by the controller's remaining service life, not by which software is newest. If the driver question is part of a wider panel replacement, the hardware choice is separate from the software question and follows the cut-out and environment, not the driver list.
Questions asked
Can I copy driver files from one EasyBuilder Pro installation into another?
No supported procedure exists for that. Drivers are built into the software release by whoever compiles it, not loaded as separate files, so a file copy is an unsupported modification and can break the installation. Keep the project on the build that contains the driver.
Will a newer generic EasyBuilder Pro release add the exclusive driver later?
Only the distributor that wrote the driver can add it, and only to its own distribution. A generic release lists the drivers the software manufacturer supports; it will not gain a distributor's private driver, so waiting for it is not a plan.
Does the exclusive driver work on any HMI model?
Driver support is scoped per model and per software build. The distributor's build lists which of its panels the driver supports; check that list against your panel model before changing either the software or the hardware.
What should I record before touching the working installation?
Record the installed distributor software version from its About window, keep a copy of the working project file and the compiled download, and note the panel model and firmware. That record is what the distributor needs to answer an upgrade question precisely.