Comparison
What cMT Touch Gesture model compatibility depends on
Short answer
cMT Touch Gesture model compatibility depends on two checks: a capacitive touchscreen on a cMT-X model, and that model's documented object support in EasyBuilder Pro, where the object accepts up to 23 gestures. The cMT-FHD-X is not listed for it, but with a multi-touch display it still reacts to pinch-to-zoom on Trend Display objects.

On this page
cMT Touch Gesture model compatibility depends on two checks, not one: a capacitive digitizer on a cMT-X model, and that model's documented object support. Only capacitive touchscreen cMT-X models support the Touch Gesture object in EasyBuilder Pro. The cMT-FHD-X is not on the supported list: paired with a display that supports multi-touch, it still reacts to pinch-to-zoom on Trend Display objects, but that reaction belongs to the Trend Display object, not to the Touch Gesture object. A multi-touch display in front of a headless unit proves the input path only, never the object list.
What the Touch Gesture object gives a project #
The Touch Gesture object is configured in EasyBuilder Pro, the Weintek engineering tool, and the object supports up to 23 touch gestures. The same user manual, Chapter 13, Objects, documents two-finger zoom in and zoom out gestures on capacitive touchscreens, which is why the object's availability follows the digitizer hardware rather than the model name on the box. Identifying the tool comes first, the same way it does when you decide which software an MT8000 series HMI needs; only then does the object list of the exact target model matter.
Which models support the object #
The supported set is short: capacitive touchscreen cMT-X models. Everything else in the cMT range sits outside it, including the cMT-FHD-X family, whose multi-touch behavior comes from a different object altogether.
| Model and hardware | Touch Gesture object | Multi-touch behavior |
|---|---|---|
| Capacitive touchscreen cMT-X | Supported | Full gesture set through the Touch Gesture object, plus two-finger zoom |
| Resistive cMT-X variant | Outside the supported set | Single-point touch only; no gesture object |
| cMT-FHD-X with a multi-touch display | Not listed as supported | Pinch-to-zoom on Trend Display objects |
| cMT-FHD-X with a single-touch display | Not listed as supported | No multi-touch reaction |
Read the table by column, not by row label: object support is a per-model fact in the documentation, and an HMI terminal is not compatible with a PLC by brand alone in exactly the same way a gesture object is not compatible by family name alone. The word capacitive, on the datasheet of the exact model, is the qualifying condition; the cMT-X name on its own does not carry the object.
Why the cMT-FHD-X still zooms a trend #
Pinch-to-zoom on a Trend Display object is behavior of that display object reacting to multi-touch input from the screen connected in front of the unit. It runs without the Touch Gesture object, so its presence proves nothing about the object list. This matters on the bench: a cMT-FHD-X demonstration with a multi-touch monitor can look fully gesture-capable while the object your project actually needs is absent from the editor's palette for that target. Gesture support tied to the object rather than the panel is a common pattern across HMI platforms; pinch-to-zoom gesture support in TIA Portal is likewise an object-level setting on Unified Comfort Panels, not a property of the terminal as a whole.
Where the cMT-X line divides #
The cMT-X series runs in four model levels: basic, standard, advanced and headless. The cMT X Standard level pairs a 15.6 inch 1920 x 1080 wide-viewing-angle LCD with a quad-core CPU behind an edge-to-edge glass front. The cMT-FHD-X family works with the headless approach: the cMT-FHDX-820 (W) sends HMI video and audio to an external monitor at up to 1920 × 1080 resolution, which is exactly why its multi-touch behavior depends on the display you connect rather than on the unit alone. For a gesture project, pick the level by your screen and CPU needs, then confirm the word capacitive on that model's datasheet before design freeze; a headless unit plus a multi-touch monitor is an input-hardware combination, not a supported-model statement.
Counting the gestures for a trend-and-recipe screen against the 23-gesture ceiling #
Take an example screen that must recognize six gestures: two-finger zoom in, two-finger zoom out, swipe up, swipe down, swipe left and swipe right. The inputs: six gestures from your project sketch, and the documented ceiling of 23 touch gestures for the Touch Gesture object from the EasyBuilder Pro user manual, Chapter 13, Objects. The rule: every gesture the screen must recognize counts once against that ceiling. The arithmetic: 2 zoom gestures + 4 swipes = 6 gestures used; 6 ≤ 23; spare capacity = 23 − 6 = 17 gestures. The result: the example screen fits in one Touch Gesture object with room to grow.
The decision: at or under that ceiling, one capacitive cMT-X model covers the screen; on a cMT-FHD-X the available count is zero because the object is unsupported, so this screen forces the capacitive cMT-X choice, and if the list later grows past the ceiling the design must split the gestures across screens or drop some.
The selection decision #
- New project that uses the Touch Gesture object: specify a capacitive cMT-X model, and freeze the choice only after the datasheet confirms a capacitive touchscreen on that exact model.
- Existing cMT-FHD-X: design around Trend Display pinch-to-zoom only, with a multi-touch display connected, and remove any screen that depends on the Touch Gesture object.
- Before design freeze, download the project and try every gesture on the actual unit; when a gesture fires a macro that misbehaves, debugging macros in cMT Diagnoser on cMT and cMT-X HMIs is the tool for finding out what ran.
- Read a multi-touch display in a specification as an input-hardware fact only; it never proves Touch Gesture support for the model behind it.
Questions asked
Can a firmware or EasyBuilder Pro update add the Touch Gesture object to a cMT-FHD-X?
No documented update path adds the object to that model. Support is stated for capacitive cMT-X hardware, and a newer editor version changes the tools on your PC, not a model's place on the supported list, so plan the cMT-FHD-X around Trend Display pinch-to-zoom instead.
Does two-finger zoom also work on a Trend Display on a capacitive cMT-X?
Yes, and there is one practical difference from the cMT-FHD-X case: because the Trend Display zoom reaction runs inside that object rather than through the Touch Gesture object, it does not consume any of the 23-gesture ceiling, so a capacitive cMT-X gives you the trend zoom for free on top of whatever gestures you configure. Verify the reaction on the bench after downloading, since it is object behavior, not a panel-wide setting.
What display does a cMT-FHD-X need for the trend zoom reaction?
An external monitor that itself supports multi-touch, connected to the unit's monitor output. A single-touch monitor gives the Trend Display nothing to react to, and the monitor's multi-touch rating still does not add the Touch Gesture object to the supported list.