Why the MT8000 series HMI model entry goes missing

HMI and touchscreens Published 4 min read By IMDTouch engineering team

Short answer

An MT8000 series unit such as the MT8106iP is programmed with EasyBuilder Pro, version 6.08.01 or later, and no legacy package. In the model list, pick the combined MT8102iP / MT8106iP entry, which sits above the cMT and HMIxxxx sections. If that entry is missing, your installed distribution is outdated or came from software that uses different model prefixes, so reinstall the current package instead of switching tools.

On this page
  1. The software the datasheet documents
  2. Where the model entry actually sits
  3. Why the entry goes missing
  4. The fix, in order
  5. How you verify the fix
  6. Questions asked

An MT8000 series panel such as the MT8106iP is programmed with EasyBuilder Pro — the datasheet lists version 6.08.01 or later — and no legacy package is required. In the project's model list, select the combined MT8102iP / MT8106iP entry, which sits above the cMT and HMIxxxx groups, not inside an MT8000 folder of its own. If that entry is absent, the installed distribution is outdated or was taken from software that uses different model prefixes (names such as HMI5000 belong to Maple Systems' software line, not to Weintek's), so the fix is to reinstall the current EasyBuilder Pro package, not to switch tools.

The software the datasheet documents #

The MT8106iP datasheet names EasyBuilder Pro as the programming tool and states version 6.08.01 or later. The manufacturer's download page currently distributes 6.10.02.470, so a fresh install clears the minimum with room to spare. Nothing in the documentation points to Ezware 5000 or any other legacy package for this panel.

Decide by the model list, not by the version label alone: a build number on its own does not prove the iP model data is present, and the reported failure below happened on a build that was nominally newer than the documented minimum.

Where the model entry actually sits #

When you create a project, EasyBuilder Pro groups its targets by series, and the iP models are easy to miss. The MT8106iP is not listed under a standalone MT8000 heading; it shares a single entry with its 10-inch sibling, shown as MT8102iP / MT8106iP, positioned further up the list above the cMT section and the HMIxxxx section. Scroll from the top or type the model name into the list's search field before concluding the target is not installed.

Why the entry goes missing #

Two separate situations produce the same symptom, and only one of them is a version problem:

  • Different software line. Names built on an HMI prefix, such as HMI5000, are the convention used inside Maple Systems' programming software. If your dropdown is organized around those names, you are not running the tool built for the Weintek model list, and no amount of scrolling will produce the iP entry.
  • Incomplete or outdated distribution. One reported installation, build 6.10.01.217, showed dropdowns for the cMT series and the HMIxxxx series but nothing in the MT8000 range. On that install the combined iP entry was simply absent until the current package was installed.

The generic version of this fault — a model missing from the programming software for reasons that apply across brands — is covered in When an HMI Model Is Missing From the Programming Software. The MT8000-specific trap is the list position: engineers stop at the HMIxxxx group, see nothing, and assume the panel needs legacy software.

The fix, in order #

  1. Open the HMI model-selection list in your installed EasyBuilder Pro and search for the combined MT8102iP / MT8106iP entry, starting from the top of the list rather than the HMIxxxx section.
  2. If the entry is present, select it, open or create the project against that target, and stop here — no reinstall is needed.
  3. If the entry is absent, check where the installed software came from. If the model names carry an HMI prefix, the distribution belongs to another vendor's software line and will never show the Weintek list.
  4. Download the current EasyBuilder Pro package from the manufacturer's own download page and install it over or alongside the old copy.
  5. Reopen the model list and confirm the MT8102iP / MT8106iP entry now appears above the cMT section.
  6. Do not switch to Ezware 5000 or any legacy tool because the MT8000 range was not visible; the absence of the entry is an installation problem, not a hardware requirement.

Only download the engineering tool from the manufacturer or its authorized distributors — an installer from anywhere else can carry the wrong model data or worse.

How you verify the fix #

Verification is binary: EasyBuilder Pro exposes the combined iP entry, and a project created with MT8102iP / MT8106iP selected compiles cleanly for that target. If you want proof beyond compilation, connect the panel and run the project against it, or rehearse on the bench first using the method in Testing HMI Simulation Against a Live PLC. A successful compile-and-download on the real panel closes the case; anything short of that means the model data still is not in the install.

The decision, for each case: model entry present — use it, you already have the right software. Entry absent and your model names carry an HMI prefix — you installed the wrong software line, replace it with EasyBuilder Pro. Entry absent and your software is genuine EasyBuilder Pro — the distribution predates the iP model data or is incomplete, install the current package. In no case does the MT8106iP call for legacy software.

If the panel itself is aging or discontinued and the real project is a replacement, the software question folds into the migration question addressed in Which HMI Software Works With Which HMI Panel Hardware.

Questions asked

Does an MT8106iP need legacy programming software such as Ezware 5000?

No. The documented tool is EasyBuilder Pro, version 6.08.01 or later. Ezware 5000 belongs to a different vendor's software line, and its HMI5000-style naming is a prefix that never matches the Weintek model list, so a missing MT8000 entry is never a reason to switch to it.

Which EasyBuilder Pro release first supports the MT8106iP?

The MT8106iP datasheet lists EasyBuilder Pro 6.08.01 as the minimum, with later releases also supported. Older installs, including a reported 6.10.01.217 build that only showed cMT and HMIxxxx groups, predate or omit the iP model data, so install the current package rather than hunting for that exact build.

Why does my model list show HMIxxxx entries instead of the MT8000 range?

HMIxxxx names are the prefix convention used by software that was not built for Weintek hardware, so the list is ordered around series that are not yours. Reinstall EasyBuilder Pro from the manufacturer's own download page, reopen the model list, and look for the combined MT8102iP / MT8106iP entry above the cMT section.

Keep reading

  • Troubleshooting

    When an HMI Model Is Missing From the Programming Software

    The model-selection list in HMI programming software contains only the panels whose definitions are installed on that workstation, so a missing model means missing model support. Run the editor's model-support setup utility from its own installation directory, or get the software upgrade from the vendor, and never substitute the nearest similar model number.

    HMI and touchscreens

  • Explainer

    Is There One Software That Programs Every HMI Panel

    No single software programs every HMI panel. Each manufacturer ties its panels to its own engineering tool, and one maker can use a different tool per panel family. Identify the panel from its nameplate, confirm the editor against the manufacturer's documentation, and plan on one editor per panel family.

    HMI and touchscreens

  • Comparison

    Which HMI programming package an 840D sl needs by software version

    The 840D sl's controller software version picks the toolchain. On SW 2.x, the existing 6FC5253-7BX20-6AG0 HMI Programming Package and your HMI Advanced applications carry over with minor adaptations. On SW 4.x the operator interface is Sinumerik Operate, applications must be rewritten with Create MyHMI/3GL (6FC5861-1YC41-1YA0, version 4.5 SP1) in .NET or C++ with Qt, and a different HMI OA option must be activated on the control.

    HMI and touchscreens

Using Vijeo Designer 6.2 to program an HMISTU series HMI