Why HMI User Credentials Do Not Show in User Administration

HMI and touchscreens Published 7 min read

Short answer

HMI user administration shows account names and their permission assignments, but passwords are stored as one-way secrets and are never displayed, even to someone holding the engineering project. The supported route is to add the new operator account with an account that already holds user-management rights, or to use the vendor's documented recovery procedure.

On this page
  1. Why can I not see the passwords in the user administration editor?
  2. What can I actually see about the configured users?
  3. Why does my project user list not match the users on the running HMI?
  4. How do I add a new operator user when I do not know the administrator password?
  5. How do I verify the new user can actually run the machine?
  6. What should I never do to get a password back?
  7. Quick answers to the questions behind this fault
  8. Questions asked

You cannot see the login credentials of the users configured in an HMI project, no matter which editor you open, because the engineering software stores passwords as one-way verification secrets and offers no display or export of them. What user administration does show is the account names, their group membership and the permission levels assigned to each one, and that is enough to solve the actual problem: adding a new operator. The path is to log in with an account that already holds user-management rights, create the new operator account, and assign it only the permissions it needs. If no such account is known, the supported route is the vendor's documented recovery procedure for that exact product and version, not an attempt to read the stored secret.

Why can I not see the passwords in the user administration editor? #

The editor never shows passwords because a password is an authentication secret, not a configuration value. When a password is set, the software stores a verification value derived from it; when someone logs in, the entered password is processed the same way and the two values are compared. The original text is not kept anywhere in the project database, so there is nothing to reveal even with full access to the project files.

This is the same design every HMI product uses, and it is the reason a masked password field is a dead end in troubleshooting. Authentication checks who the user is; authorization decides what that user may do. The user administration view exposes the authorization side (names, groups, permission levels) and deliberately hides the authentication side. Two engineers who hold the same project can see that a user called, for example, maintenance1 has the highest permission level, but neither can find out what that user's password is.

Separate the two before you troubleshoot further. Your requirement is to add an operator, which is an authorization task. You do not need to recover anyone's password to do it, and the term super user is informal shorthand anyway: what matters is which account holds the permission that governs user management.

What can I actually see about the configured users? #

You can see the account names, their group assignments and the permission level of each, and that list tells you which accounts exist and what they are allowed to do. Open the user administration editor in the engineering software for your product and version; the layout differs between products and versions, but every one of them presents the same three things: users, groups and permissions.

The permission level attached to each account is the value you are looking for. Screen objects and buttons are protected by permission levels or group rights, and an account that logs in successfully but lacks the level a control references will still be unable to operate it. Check which levels the operator screens actually require, then you know exactly what the new account needs.

Note the account that holds user-management rights while you are there. That is the account you will use to make the change, and knowing it exists in the project is what makes the whole job possible without any password recovery.

Why does my project user list not match the users on the running HMI? #

The project file and the deployed runtime can hold different user lists because runtime account changes, repeated downloads and stale project copies all move the two apart. If the machine has been serviced by others, someone may have added or changed accounts directly in the running terminal, and that state only reaches your project when it is uploaded again.

Before trusting the list you see in the engineering software, check these in order:

  • Confirm the project revision against the deployment record, or ask the machine owner when it was last downloaded and by whom.
  • Upload the current application from the terminal if your product supports it, and compare its user administration with your project copy.
  • Check whether the installation authenticates against a source outside the project, such as the Windows account database on a PC-based runtime, because then the authoritative user list is not in the project at all.
  • Ask whether any runtime-side user management feature was used, since accounts created that way exist only on the terminal.

If your user changes work in the engineering simulation but have no effect on the machine, the account database you edited is not the one the runtime is using, and the comparison above will show you where the divergence is.

How do I add a new operator user when I do not know the administrator password? #

Use an account that already holds user-management rights to create the operator; if none is known, use the vendor's documented recovery procedure for that exact product and version. Both are supported paths; neither involves displaying the stored secret.

  1. Get written authorization from the machine owner, and back up the current project and its user configuration so the change is reversible.
  2. Log in at the runtime, or open the engineering project, with the account identified earlier as holding user-management rights.
  3. Create a new operator account with its own password in the authoritative account source, and assign only the permission levels the operator screens require.
  4. Deploy the change using the product's documented download procedure, and check beforehand whether that download overwrites accounts created at runtime; the interaction between a downloaded project and runtime-created accounts is product specific, and it is worth reading how password and account handling works across a download before you commit.
  5. Record the new account, its permissions and who authorized it.

If no account with user-management rights is known, request the documented recovery process from the machine owner, the integrator or the vendor's support channel for that product. Recovery typically means overwriting credentials or restoring a known configuration, and it ends with a new administrative login you control. For background on how one established product line designs this, the security model behind operator account passwords and their documented recovery procedures is a useful comparison.

How do I verify the new user can actually run the machine? #

Log in as the new operator in a fresh session and exercise every protected control that operator's job requires, because a successful login proves authentication but not authorization.

Log the existing session out first, so a logged-in administrator does not mask a missing permission. Then open each screen the operator uses and confirm the protected controls are enabled rather than showing as locked. Finally perform one approved operation under controlled conditions, such as starting a conveyor on the bench or during a planned stop, and confirm the runtime accepts it without demanding a higher permission level. If a control stays locked, compare the permission level that control references with the levels you assigned, and adjust the account rather than the screen.

What should I never do to get a password back? #

Never use a third-party cracking tool, a shared default password list or a database hack on a machine that is going to run. Password protection on an HMI guards machine actions that can injure people, and the supported recovery path exists precisely so that access control stays auditable. If the vendor offers a documented reset for your product, use it as the documentation presents it, with the machine owner's authorization and a backup taken first.

One safety note belongs here: before testing any new account's permissions against live machine motion, put the machine in a state where an unexpected start cannot hurt anyone, and tell the people around it what you are doing and when.

Quick answers to the questions behind this fault #

The decision in every case: read the user administration to learn who exists and what they may do, act through an account that holds user-management rights, or use the vendor's documented recovery if no such account is known. The password itself stays unreadable by design, and the job never needed it. The same separation of authentication from authorization explains why a project file alone cannot hand you a login: holding the project proves nothing about who may change the machine's access control. Where a related symptom is a user list that behaves differently in simulation than on the panel, or accounts that vanish across a download, follow the checks in the sections above.

Questions asked

Can any tool reveal a password that was already set in an HMI project?

No supported engineering tool displays an existing password. The value is stored as a verification secret, not as readable text, so there is nothing in the project database to view. If the password is unknown, the supported options are to overwrite it with a new one using an authorized account, or to follow the vendor's documented recovery procedure for that product.

What should I do before changing any user on a machine I do not own the passwords for?

Get written authorization from the machine owner, note which account currently holds user-management rights, and back up the current project and its user configuration. Changing the administrator account or replacing the user list can lock out the people who service the machine, so the change must be recorded and reversible before you touch anything.

Does a new HMI user account need the same permissions as the administrator?

No. Give the operator account only the permissions its screens and protected controls reference, such as starting the process or acknowledging alarms. Sharing one administrator login among all operators removes accountability and makes later troubleshooting harder, because the runtime cannot tell which person performed a change.

Where do password rules for HMI users get configured?

In the runtime user administration settings of the engineering software. That editor is where password length and change rules are defined, and where individual users and groups are assigned their permission levels. The exact menu layout depends on the product and version, but the settings live in that user administration area rather than in the screen editor.

Keep reading

  • How-to

    Copying One Structure Variable to Another in Operator Terminal Expert

    Operator Terminal Expert 3.4 refuses a whole structure as a changeValue operand, so replace the one failing call with one scalar assignment per member, expanding nested structures and arrays to their leaf values. Gate the work on a clean compile plus a destination readback, and stage the copy when the consumer must act only on a complete set.

    HMI and touchscreens

  • How-to

    Where to enter Sm@rtServer credentials in WinCC Runtime Advanced

    Enter the remote user and password in Windows Control Panel under WinCC Runtime Advanced Internet, on the Remote tab, behind Change Settings in the Server tab of the dialog that opens. The Sm@rtServer checkbox in the project's runtime settings only enables the server. Record the listening port shown there and use it with the PC's address in Sm@rtClient.

    HMI and touchscreens

  • How-to

    How to Manage WinCC Runtime User Accounts and Password Changes

    Open the WinCC User Administrator at runtime by launching PassCS.exe from a button with a ProgramExecute C action, using the full installed path C:\Program Files\Siemens\WinCC\bin\PassCS.exe. Gate the button with an authorization, and keep operator login, own-password change, and account administration as three separately tested operations. Comfort and Advanced panels are administered in the engineering tool instead.

    HMI and touchscreens