IMDTouchKnowledge BaseShop main store

Explainer

Why screen windows replace central screen management

HMI and touchscreens Published 7 min read

Short answer

WinCC Unified removes the dedicated screen-management area from the project navigation. Templates, pop-up screens, slide-in screens, the global screen and the permanent area are now built as ordinary screens and displayed through screen windows arranged on a start screen that acts as the layout. Design that layout, place the principal windows on it, and target each window, not just each screen, in your navigation.

On this page
  1. What Unified removed from the project navigation
  2. What a screen window is
  3. Build the start screen as the layout
  4. Dividing a 1920 x 1080 pixel start screen into screen windows
  5. Where each old screen role goes
  6. Navigation targets a window, not just a screen
  7. Start from the HMI Template Suite
  8. Questions asked

WinCC Unified has no central screen-management area. The section you knew from the project navigation in WinCC Comfort and Advanced does not exist, and nothing took its place as a separate editor, because the work moved into the screens themselves. Templates, pop-up screens, slide-in screens, the global screen and the permanent area are all now built as ordinary screens and displayed through screen windows placed on other screens. The decision that follows from this: design one start screen as your screen layout, arrange the principal screen windows on it, and display every other screen inside those windows. This article explains what changed, what a screen window can do, and how to lay the structure out with real pixel numbers.

What Unified removed from the project navigation #

In WinCC Comfort and Advanced, screen roles lived in their own area of the project navigation: a template supplied the shared frame, the global screen carried always-present content, and pop-up and slide-in screens were managed as special screen types. WinCC Unified drops that entire area. You do not configure a screen's role in a central list anymore; you build each element as a screen and decide, screen by screen, which windows it contains and which screen each window shows.

This is not a new invention for panels. The same model has been used for years in the WinCC SCADA systems, WinCC V7 and WinCC Professional, so engineers coming from those tools will recognize it immediately. Engineers coming from Comfort and Advanced need to unlearn one habit: there is no central place where the structure of the operator interface is defined. The structure is the start screen you build.

What a screen window is #

A screen holds the display objects. A screen window is a container object that you place on a screen, and it displays another screen inside its rectangle at runtime. That distinction drives everything else: navigation between process views changes the screen inside a window, while the screen that carries the window stays put.

The documented capabilities of the screen window are what make it a full replacement for the old screen roles. A window can be nested inside another window, so a pop-up can itself contain further windows. A window can be moved and resized, and the same window can be used several times on one screen. Because windows are ordinary objects with properties, their position, size and visibility are under your control rather than fixed by a screen-management rule.

Build the start screen as the layout #

The documented recommendation for WinCC Unified projects is to create the start screen as a screen layout and to arrange and define the essential screen windows on that layout. The layout screen stays loaded for the whole runtime session. Process navigation swaps the screen inside the process-content window; the layout and its other windows are never touched.

This is also how persistence works now. Content that operators must always see goes either directly onto the layout screen or into its own window beside the process window. It remains visible because nothing in normal navigation replaces the containing screen. Replace the layout screen itself and you replace every area it owns, so keep layout changes to engineering and commissioning, not operation.

Dividing a 1920 x 1080 pixel start screen into screen windows #

This worked example shows how the window geometry falls out of the display size. The inputs: the runtime resolution is configured in the runtime settings of the Unified project, and 1920 x 1080 pixels is the value Siemens uses in its own resolution example for both the runtime and a web client at the same size. The subdivision below is my illustrative arrangement, not a documented rule. The requirements come from a typical machine station: one row of shared navigation at the top, a permanently visible message bar, and the largest remaining area for changing process content.

The rule in words: if you stack full-width windows from the top edge, their heights must add up to the screen height, and each window's vertical position is the sum of the heights above it.

The arithmetic, with the header at 120 pixels and the message bar at 80 pixels:

  • Header window: 1920 x 120 pixels, position x = 0, y = 0.
  • Message window: 1920 x 80 pixels, position x = 0, y = 120.
  • Process window height: 1080 - 120 - 80 = 880 pixels, so 1920 x 880 pixels at position x = 0, y = 200.

The check: 120 + 80 + 880 = 1080 pixels, which matches the screen height, so no window overlaps another and nothing spills off-screen.

The decision: 120 pixels holds one row of navigation buttons, so if your header needs two rows, raise it to 160 pixels and the process window drops to 1080 - 160 - 80 = 840 pixels. Verify the target panel's actual resolution before locking these coordinates, because every number above is a pixel value tied to that one display size.

Where each old screen role goes #

Comfort or Advanced element WinCC Unified treatment
Template Shared objects placed directly on the layout screen, or a dedicated shared-content screen shown in its own window
Global screen Its required content assigned to an explicitly owned area or window on the layout
Permanent area A reserved region of the layout outside the process-content window, often its own window
Pop-up screen An ordinary screen displayed in a window whose visibility you show and hide
Slide-in screen An ordinary screen in a window you position at the layout edge and reveal on demand

Copying the old template graphics into every process screen reproduces the appearance but creates independent copies that drift apart at the first modification. Give each shared function one owner: the layout, or one shared screen in one window. When you plan to carry these screens forward into other controllers, that single-owner structure is exactly what makes reusing HMI screens across different PLC projects practical instead of a copy-and-paste exercise.

Every screen change now has two parts: the destination screen and the destination window. Selecting the correct screen is not enough if the action replaces the whole layout when it should only refill the process window. Treat the target window as part of every navigation requirement, and configure process-page buttons so they change only the process-content window.

The same discipline applies to screen changes triggered by the controller. Setting a screen number or screen name from the PLC works identically in Unified, but it must address the window you intend; the procedure is the one described in changing the HMI screen from the PLC in WinCC Unified. On installations with more than one display, keep each window's navigation aimed at its own window rather than the whole runtime, for the reasons set out in keeping WinCC dual-monitor navigation inside picture windows. Once the windows exist, the content inside them follows the same readability rules as any other screen, which is where designing HMI screens for clear operator decisions earns its keep.

A practical test on the bench: operate each navigation control and watch which region changes. Only the process window should move; the header, the message bar and any other layout content must hold still. Repeat the test from a different process screen, because a button that works only from the start screen is addressing the wrong window.

Start from the HMI Template Suite #

You do not have to build the layout from an empty screen. The HMI Template Suite for WinCC Unified provides a library and a wizard that create a structured starting layout for panel and PC runtime projects, with the screen layout and the whole screen-management structure already laid out. Use it as the skeleton, then open the resulting screens and check which window owns which content before you adapt navigation, so later changes preserve the intended ownership instead of accidental duplicates.

The WinCC Unified Tutorial Center also covers this ground: it includes a video on creating a screen layout, found under the screen-design section of its index. Between the Template Suite for structure, the start screen as your layout, and window-targeted navigation, the old central screen-management area has no job left to do. That is the model to commit to on every Unified project, new or migrated.

Questions asked

Can a screen window contain another screen window?

Yes. Nesting a screen window inside another screen window is a documented capability of WinCC Unified, and it is one of the main reasons the old central screen management area was dropped. The same window object can also be moved, resized at runtime configuration, and placed more than once on the same screen, so a pop-up is simply an ordinary screen shown in a window whose visibility you toggle.

Where do I put content that must always stay visible?

Put it directly on the start screen that serves as your layout, or show it in its own dedicated screen window next to the process-content window. It stays visible during operation because process navigation only changes the screen displayed inside the process window. The containing layout screen never closes, so anything placed on it or in a sibling window remains on view for the whole session.

Is the screen-window model new in WinCC Unified?

No. The larger WinCC SCADA systems, WinCC V7 and WinCC Professional, have displayed screens through screen windows for many years. WinCC Unified brings the panel engineering from WinCC Comfort and Advanced onto that same model, which is why Comfort and Advanced projects need their central screen-management entries reworked into screens and windows during migration.

What resolution should the start layout be drawn for?

Set the runtime resolution in the runtime settings of the Unified project and match it to the panel or web client display the operator actually uses. Drawn positions and window sizes are pixel values, so a layout produced for one display size will misalign on another. Check the target display resolution before you lock the window coordinates, then keep the web clients on a matching resolution.

Keep reading

  • Troubleshooting

    Adapt picture in WinCC 7.4 so migrated screens fit the new resolution

    Set Adapt Picture twice: once on the Graphics Runtime container under Computer Properties and once on every embedded picture window, because the runtime flag does not reach child picture windows. The OS Project Editor only remaps the design resolution; it does not scale the graphics into the space it frees. On clients, the @pclocal:: prefix fixes I/O fields but trend controls can keep plotting server data.

    HMI and touchscreens

  • Explainer

    Why WinCC Unified screens have no Openness export method

    In TIA Portal Openness V17 a WinCC Unified Comfort screen is the type Siemens.Engineering.HmiUnified.UI.Screens.HmiScreen, and that type exposes no Export(FileInfo, ExportOptions) method — there is no screen-XML export or reimport. The supported path is to edit the Unified device's engineering objects directly through the object model; a FileInfo plus a success message writes no file.

    HMI and touchscreens

  • How-to

    How to Build Two-Level Tab Navigation With Child Screens in WinCC

    Build two-level navigation in WinCC with one persistent main picture, a picture window for content, and visibility-controlled child menus. Each main-tab press must set three things at once: the tab's own selected state, the matching child menu, and the initial child picture. A graphics group only bundles objects in the editor and creates no runtime navigation.

    HMI and touchscreens