Where to Find the Symbol Library in WinCC Graphics Designer

HMI and touchscreens Published 5 min read By IMDTouch engineering team

Short answer

In classic WinCC, the symbol library lives inside the Graphics Designer picture editor: open a PDL picture and select View > Library to expose the Global Library and the project library. You extend it with your own WMF or EMF vector files, and custom ActiveX controls reach the palette through Add/Remove Controls.

On this page
  1. Where is the symbol library in WinCC Graphics Designer?
  2. What does the Global Library contain?
  3. How do I add my own symbols to the library?
  4. How do I add a custom or third-party ActiveX control to the palette?
  5. When is IndustrialX the right tool?
  6. Does this apply to TIA Portal panels and WinCC Unified too?
  7. How do I keep a large symbol set organized across many pictures?
  8. Questions asked

The symbol library in classic WinCC is not a separate program or download: it opens inside the Graphics Designer picture editor. Open WinCC Explorer, go to the Graphics Designer tree, open any PDL picture, then select View > Library in the editor's menu bar. The library view replaces the object palette and shows the Global Library installed with WinCC plus a project library that belongs to the project you have open.

Where is the symbol library in WinCC Graphics Designer? #

Open a picture in Graphics Designer and choose View > Library; the library palette opens in place of the object palette. Nothing else needs to be installed or licensed, because the symbol library ships as part of the WinCC engineering installation and is documented in the Working with WinCC manual for V7 and V8 alike.

If the menu entry stays greyed out, the most common cause is that no picture is open: the library belongs to the picture editor, not to WinCC Explorer. Create a new picture or open an existing one from the Graphics Designer tree first.

What does the Global Library contain? #

The Global Library holds the symbol collections installed with WinCC, organized in folders by equipment family, so you browse to a category and drag the object straight onto the picture canvas. Each entry is a graphic object you can scale and configure like any other picture object, with appearance and dynamics set through its object properties.

These icons are meant to represent plant areas and equipment in process pictures, so a typical screen gets its pumps, valves and vessels from here before you add dynamics. Drag the symbol once, drop it, and repeat placements are copies of the same library object.

How do I add my own symbols to the library? #

Store your own graphics as WMF or EMF files and place them in the project library, and they appear alongside the stock symbols in the View > Library palette. WMF and EMF are Windows vector metafile formats, so a symbol you draw once scales cleanly to whatever size the picture needs.

The practical workflow, for example building a project library with a consistent pump set:

  1. Draw or export the symbol as a WMF or EMF file from your graphics or CAD tool.
  2. In the Graphics Designer library view, open the project library side of the palette.
  3. Add your files to the project library so each one becomes a reusable library entry.
  4. Drag the entry onto the picture and set its size through the object's geometry properties; the vector scaling stays sharp.

Keep the project library, not the Global Library, for anything project specific. The Global Library is shared across every project on the station, so a symbol saved there follows the station rather than the project when you archive or hand over the project.

How do I add a custom or third-party ActiveX control to the palette? #

Custom ActiveX controls do not come through the symbol library at all: you add them to the object palette in Graphics Designer using the Add/Remove Controls dialog. After a control is registered on the engineering station, tick it in that dialog's list and it appears as a placeable object in the palette, which you then drag into the picture like any other control.

One detail worth checking before you rely on a third-party control: the WinCC documentation notes that custom ActiveX controls depend on the Visual Studio version they were built with, and that you may need to install matching runtime components on the station. A control that renders but refuses to script is usually a mismatch of that kind, not a WinCC configuration fault.

When is IndustrialX the right tool? #

IndustrialX is the documented WinCC mechanism for wrapping a custom or third-party ActiveX control so it behaves like a first-class WinCC object with tag connections and configuration dialogs, and Siemens covers it in the WinCC online help under Industrial X. It earns its setup time when a vendor's graphic must respond to process tags, not just sit on the screen as a picture.

If the goal is only a nicer static icon, stop at the WMF/EMF project library route: it needs no development environment and no registration. Reserve IndustrialX for controls whose properties you intend to drive from scripts or tags.

Does this apply to TIA Portal panels and WinCC Unified too? #

No, the Graphics Designer library belongs to classic WinCC V7 and V8 only. TIA Portal panels, Comfort Panels and Runtime Advanced have their own symbol library entry in the screen editor, documented separately, and WinCC Unified manages reusable graphics as types you add to a project library rather than as a Graphics Designer palette.

If you are migrating pictures between generations, expect to rebuild library-based graphics on the target system rather than copy the library folders. The symbol names, storage and reuse mechanisms differ by generation, so budget that rework into the migration.

How do I keep a large symbol set organized across many pictures? #

Split the project library by equipment family and name every entry before it is first placed, because a picture with hundreds of unnamed dragged-in objects becomes unsearchable within weeks. The same reuse discipline applies to text: the way WinCC text lists are configured for reuse across PDL pictures pairs well with a tidy library when several pictures share the same equipment wording.

For screens that need animated equipment, connect dynamics to the placed library objects rather than redrawing: an object animated from a PLC tag keeps its library origin, so a later correction to the symbol propagates to the new placements. The mechanics of driving an object's position or appearance from a tag are the same ones used when you animate WinCC objects from PLC tags in a process picture.

Questions asked

Does the symbol library shortcut differ between WinCC V7 and WinCC V8?

No. In both classic WinCC versions the symbol library is a Graphics Designer feature, opened from the picture editor's View menu. The documented content and management of customized objects and controls in the symbol library, plus a separate SVG library, appear in the Working with WinCC documentation for these versions.

What is the difference between the Global Library and the project library?

The Global Library is installed with WinCC and is shared by every project on the engineering station, so the symbols there are read-only reference graphics. The project library travels with the project and is where you store your own objects, so a colleague opening the same project gets your symbols without installing anything.

Why should I prefer WMF or EMF files over PNG bitmaps for library symbols?

WMF and EMF are Windows vector formats, so a pump or motor symbol stays sharp when an operator zooms the picture or when you resize the object on screen. A raster image of the same symbol turns blocky once it is scaled beyond its native pixel size, which shows quickly on high-resolution panel PCs.

Do panels and Comfort Panels use the same library as classic WinCC?

No. TIA Portal panels, Comfort Panels and Runtime Advanced have their own symbol library entry in the screen editor, documented separately from the classic Graphics Designer library, and WinCC Unified manages reusable graphics as types in a project library instead.

Do I need any extra installation to use the built-in symbol library?

No. The symbol library is part of Graphics Designer, which comes with the WinCC engineering installation. You only need a picture open in the editor for the View menu entry to be available; nothing is downloaded or registered separately for the stock symbols.

Keep reading

  • How-to

    Adding Flowmeter and Sensor Graphics to an EasyBuilder Pro Screen

    EasyBuilder Pro has no dedicated flowmeter or temperature-sensor object, and it does not need one. Put a picture from the Shape or Picture Library (or your own imported image) on the screen to identify the instrument, then add a separate numeric object bound to the device address for the live measurement — the picture never carries the data connection.

    HMI and touchscreens

  • How-to

    How to find configuration software for a legacy TP070 touch panel

    A TP070 is configured with TP Designer, the add-on that shipped in the STEP 7 Micro/WIN Toolbox era and runs under Micro/WIN V4 — not with WinCC flexible, ProTool or TIA Portal. Read the order number on the rear label to match the toolset to the panel's firmware generation, source the package through the manufacturer's own channels, and transfer over PPI at 9.6 kbit/s.

    HMI and touchscreens

  • Troubleshooting

    Why OP77B Softkeys Are Missing in Direct .fwx Runtime

    The missing softkeys are not a project fault. A direct .fwx start runs WinCC flexible Runtime without the simulated panel face, so only the screen area appears and only the PC keys F1 to F4 and ESC work; start Runtime from the engineering system instead, and the simulator draws the complete OP77B with softkeys, numeric keys, arrow keys and status LEDs, all operable with the mouse. The SimulateSystemKey function covers K1 to K4 in .fwx mode.

    HMI and touchscreens

Importing flb symbol libraries into EasyBuilder projects