How-to
Where to get STEP CAD files for a TP1200 Comfort PRO
Short answer
The STEP file for the TP1200 Comfort PRO support-arm variant, article number 6AV2124-0MC24-0BX0, downloads free of charge from the Siemens Industry Image Database. Search the complete article number, take the .stp asset rather than .jt, .edz or photos, import into a fresh CAD document, and measure one overall dimension against the dimensional drawing before the geometry enters your layout.
On this page
- Where can you download the TP1200 Comfort PRO STEP file?
- Which article number matches your support-arm variant?
- Which file format do you take from the download list?
- How do you check the imported model for the right scale?
- Does the download include the support arm and Extension Unit?
- How do you run clearance and access checks in the layout?
- What do you record before the layout is released?
- Questions asked
The STEP model for a SIMATIC HMI TP1200 Comfort PRO is not something you request from a distributor: Siemens publishes the CAD data for article number 6AV2124-0MC24-0BX0 — the support-arm version, extendable, round-tube arrangement, with Extension Unit — in its Industry Image Database, free of charge. Search the complete article number rather than the family name, take the .stp file from the record's CAD graphics instead of the .jt visualization, the .edz CAx package or the photos, import it into a fresh CAD document, and measure one overall dimension against the dimensional drawing before the solid earns a place in your assembly. This article walks through the download, the format choice, the scale check, the assembly-boundary check and the clearance work that turn a downloaded model into layout you can release.
Where can you download the TP1200 Comfort PRO STEP file? #
The Industry Image Database on Siemens' automation portal carries the record for the TP1200 Comfort PRO support-arm variant, and its CAD graphics download free of charge, so the STEP file comes from a public database rather than a request to your distributor.
The database is Siemens' public media service for automation products: photos, graphics, 3D models and engineering data in several variants, published for presentation and engineering work. It also carries device outlines, terminal layouts and dimensional sketches, which makes it the secondary source for the drawing your scale check needs later.
- Open the Industry Image Database from the Siemens automation portal and set the search field to the article number, which Siemens labels MLFB.
- Enter 6AV2124-0MC24-0BX0 in full, every dash group included, and start the search.
- Open the record whose description names the support-arm version, extendable, with round-tube arrangement and Extension Unit.
- Download the .stp file from the CAD graphics entries and keep the original filename, so the asset stays traceable to the article number.
- Note the download date beside the filename in your project; product data gets updated, and the layout should record which download it was built from.
Which article number matches your support-arm variant? #
Article number 6AV2124-0MC24-0BX0 names the TP1200 Comfort PRO built for a support arm — extendable, round-tube arrangement, with Extension Unit — and that complete number, not the display family name, is what selects the record whose geometry matches the hardware on your machine.
The Comfort line shares display sizes across mounting variants, and the variants do not share geometry: a panel-mount housing carries a sealing collar and cut-out dimensions, a support-arm unit carries the round-tube interface on its rear, and pedestal mounting raises hardware questions of its own, down to which base adapter mounts a TP1500 Comfort PRO on a pedestal. A family name fixes none of that, so confirm the variant by the record's description, not by the first search hit.
If this layout exists because the panel is being replaced, apply the same discipline you would use when verifying an obsolete HMI replacement before ordering: complete article number, variant description, then geometry.
Which file format do you take from the download list? #
Take the .stp file: STEP is the neutral CAD exchange format that imports as clean solids for layout, while the .jt file is a lighter visualization model, the .edz package feeds a CAx engineering tool, and the .jpg, .tif, .png and .eps files are pictures only.
STEP is the ISO 10303 exchange standard, whose job is to move exact 3D geometry between systems without either system's native quirks, which is why the same .stp reads into any serious CAD importer. The database organizes its assets by category:
| Asset on the record | Extension | What it serves | Role in this layout |
|---|---|---|---|
| CAD graphics | .stp | Neutral 3D geometry for CAD import | The deliverable |
| CAD graphics | .jt | Lightweight visualization geometry | Fallback when STEP cannot be imported |
| CAx data | .edz | Engineering-data package for a CAx tool | Take it too when your CAx tool reads it |
| Photos | .jpg, .tif, .png, .eps | Identification and documentation | Never as geometry |
The categories describe what the database can hold; the record's own asset list decides what this article number actually carries, so read it rather than assuming. Because the STEP solid is clean geometry, the same file also converts to an STL mesh when you later need a 3D-printed cover, shroud or adapter block around the unit, and the walkthrough of 3D printing SIMATIC covers from an STP model shows that export step.
How do you check the imported model for the right scale? #
Import the .stp into an empty CAD document, confirm the translator's unit setting, and measure one overall dimension — the front bezel width is the easiest — against the value printed on the dimensional drawing for your exact article number before the solid goes anywhere near the assembly.
A filename appearing in the assembly tree proves nothing. A STEP import can deliver solids, surfaces or a scatter of separate bodies depending on the exporter and your translator, and the geometry is only usable when it is visible, correctly scaled and complete around the mounting interface. Read the translator's import log when it reports errors instead of patching the geometry by hand.
Worked example, with illustrative numbers rather than the TP1200's published dimensions: say the drawing for your exact variant states a front bezel width of 420 mm, and the imported solid measures 42.0 mm with the document set to millimeters. The scale error is 420 mm ÷ 42.0 mm = 10, so the translator dropped one decimal decade; apply a uniform ×10 scale and re-measure — 42.0 mm × 10 = 420 mm — and the import passes.
Had the import measured 16.54 mm instead, the geometry arrived in inches: 420 mm ÷ 25.4 mm per inch ≈ 16.54, so the fix is a ×25.4 scale. A factor that is not a clean unit conversion, say 1.037, means a wrong or damaged file — delete it and download the .stp again rather than stretching solids to fit.
Does the download include the support arm and Extension Unit? #
Check the model tree before you trust the scope: the record for a support-arm panel may deliver the HMI front unit only, with the round tube, clamps and Extension Unit as separate records, so every part your layout needs needs its own download by its own article number.
Open the tree and count the bodies against the hardware list — HMI front unit, support-arm interface, Extension Unit. A product model can represent one component or a small assembly, and the download alone does not tell you which until you look. Whatever is missing is a separate record to download, never a shape inferred from the neighboring geometry.
Compare the modeled connection region with the physical clamp and tube hardware: the interface must correspond to the documented mounting orientation. Fastening, permissible arrangements and anything load-related come from the installation instructions, which govern even where the CAD looks self-explanatory.
How do you run clearance and access checks in the layout? #
Constrain the imported solid at its documented mounting interface — the support-arm clamp face, not a convenient enclosure edge — then run interference against the tube, the Extension Unit and adjacent machine steel, and walk each service operation in the model before calling the layout clear.
An interference check only detects overlapping modeled volumes. It says nothing about whether a technician can insert a connector with its backshell, bend the cable inside its minimum radius, reach a fastener with a wrench, or lift the panel off the arm for service. The simplified solid omits the connector, the cable and the fastener heads, so model them or leave envelope space for them.
One safety note: torque the arm's clamping screws to the values in the arm's installation instructions, never to feel — a support arm carrying a live operator panel is a falling hazard when its clamps are under-tightened.
The layout is accepted when the interference check comes back clean and every documented service operation has room. If either fails, move the clamp position on the tube and re-run the checks; do not solve it by pinching the cable.
What do you record before the layout is released? #
Record the article number, the downloaded filename, the model scope and the dimensional comparison result in the assembly release notes, so the next engineer can reproduce the CAD selection and tell modeled parts from parts that were checked on paper.
Put four things in the release record:
- the article number and the record's variant description
- the downloaded filename, its format and the download date
- the model scope: which bodies are modeled, which parts came from separate records
- the measured-versus-drawing dimension and any scale factor that was applied
The decision, case by case: STEP present and the import measures 1:1 against the drawing — accept the geometry into the layout. Scale off by a clean unit conversion — apply the factor, re-measure, accept. Scale off by an arbitrary factor, or the import fails — delete the file and re-download before touching the design. Mounting components missing from the model — download each by its own article number, never infer them. Interference or access fails — move the mounting position and re-run. Only then does a downloaded solid become layout you can release.
Questions asked
Is the JT file an acceptable substitute for the STEP model?
Only when your CAD system cannot import STEP. A record may also offer a .jt file, which is a lightweight visualization format and often carries less complete geometry than the STEP solid, especially around mounting details and the rear housing. If you fall back to JT, run the same dimensional check against the drawing before the model enters layout, and note the substitution in the release record.
What if the record shows no STEP asset for the article number?
Use the CAx Download Manager that Siemens documents in Industry Online Support entry 89671877. It serves the current CAD and product data for a chosen article number to your CAD or CAE system, and it fills the gap when an Image Database record lists only some formats. Take the STEP geometry from there and continue with the same scale and scope checks as any other download.
Where do you find the dimensional drawing to check the import against?
It sits in the documentation set for the exact article number on Siemens' Industry Online Support portal, and the Industry Image Database itself carries device outlines and dimensional sketches as a secondary source. Use the drawing that belongs to the support-arm variant with Extension Unit, not an outline of the standard panel-mount housing, because mounting interfaces and rear dimensions differ between variants.
Should you model the missing round-tube hardware yourself?
No. Tube diameter, wall thickness, clamp geometry and the arm's load rating come from the support arm's own article number and its installation instructions, not from photos or from scaling neighboring geometry. Download the arm and the Extension Unit as their own records, and keep the modeled-versus-documented split visible in the assembly tree so nobody reads an unverified solid as checked hardware.