Why C-more Objects Seem Missing From the Object List
Short answer
The objects are not missing. From C-more programming software version 9.0 on, similar objects are combined: Numeric Entry and Numeric Display became the single Numeric Entry/Display item, with entry or display behaviour chosen by the Object Style selector in the object's configuration dialog. Typing the function you want, for example Lookup Text, in the Object List search bar filters straight to the object that performs it.

On this page
- Why can't I find Numeric Entry or Numeric Display in the C-more Object List?
- How does the Object List search bar find the merged object?
- How do you choose entry or display behaviour on the merged object?
- What happens to the objects already placed on a screen?
- Does reinstalling the programming software bring the old objects back?
- When is the missing item the panel model, not an object?
- What do you do next time an object seems missing?
- Questions asked
The objects are not missing, and reinstalling will not bring them back. From C-more EA9 programming software version 9.0 on, similar objects are combined into single items: the old Numeric Entry and the old Numeric Display are now one Object List item, Numeric Entry/Display, and you pick the behaviour inside its configuration dialog. The Object List is still the palette you drag from to the workspace to create screens, the first step of what HMI programming covers from screens to controller tags, and its search bar filters to the merged object when you type the function you want.
Why can't I find Numeric Entry or Numeric Display in the C-more Object List? #
Because from software version 9.0 on the two are one item: the Object List offers Numeric Entry/Display, a single object that performs either role, so the separate Numeric Entry and Numeric Display names no longer appear in the list. The consolidation is deliberate, not a broken installation. The list still contains every object the software offers, arranged in logical groups, and you still create screens by dragging from it to the workspace; what changed is that one item now covers roles that two items used to cover.
The numeric pair is the clearest case, because the merged item carries both old names in its own. The same combining pattern applies to other similar objects, so treat any familiar name that vanished after an upgrade as a merged item first, before you suspect your installation. The authoritative record of what was combined is the release notes for the version you run: when a name you relied on disappears, those notes list the changed items and are the first document to open.
How does the Object List search bar find the merged object? #
Type the function you want into the search bar at the top of the Object List and it filters to the object that accomplishes that function, so a search for an old name lands on its merged replacement. The filter works on what the object does, which is why a retired name is not a dead end. Typing Lookup Text, for example, narrows the list to the text object that performs that same job under the current arrangement.
The search bar sits above the groups and narrows the list as you type. Use it before you scroll: the software offers hundreds of preconfigured parts alongside the default objects, and typing a few characters beats hunting through the groups for one item.
How do you choose entry or display behaviour on the merged object? #
Open the object's configuration dialog and use its behaviour selector: on most objects it is labelled Object Style, while on others the same choice is labelled Object Mode or Object Features. The wording is not harmonized across the object set, which is why the setting is easy to miss; check all three labels before concluding the choice is absent. They are the same kind of setting, the one that decides what a placed object does.
On the merged item, that selector decides whether the object accepts an operator's input, like the old Numeric Entry, or only shows the live value, like the old Numeric Display. The choice belongs to each placement, so two Numeric Entry/Display objects on one screen can hold different settings, one entering and one displaying.
What happens to the objects already placed on a screen? #
Nothing is removed: the Object List is only the palette you drag new objects from, so every object already on a screen stays in place with the behaviour its own configuration already holds. The merge changed the palette, not the project contents, and nothing needs re-placing.
Worked example, with illustrative numbers. Take a screen built before the merge that holds 15 Numeric Entry objects and 9 Numeric Display objects. Placed objects on that screen: 15 + 9 = 24. Open the project in the current software and the screen still holds those 24 working objects, each running on its stored configuration. The palette is what changed: where it once listed 2 items for that pair it now lists 1, Numeric Entry/Display, and every new placement on that screen comes from it.
Does reinstalling the programming software bring the old objects back? #
No, because the merged list is how the installed version is built, not a damaged installation: reinstalling the same version restores the same Object List, with the same single Numeric Entry/Display item. The symptom gives it away. The software runs, the project opens, and only the names you remember are absent, while similar combined items sit in their place. That is version behaviour, not corruption.
Reinstalling earns its time only when the list misbehaves rather than consolidates. If it shows nothing at all or will not populate, the merge is not the explanation, because a healthy list still shows every object in its group; treat that as an installation fault and troubleshoot it as one.
When is the missing item the panel model, not an object? #
When the item you cannot find is the panel itself in the software's model list rather than an object on the palette, you are facing a different problem with its own fix. The two lists are unrelated: the Object List is the palette of objects you drag onto screens, while the model list is where the software offers the panel hardware for project creation.
A merged object means a similar item is present under a combined name. A missing model means the panel you want does not appear at all, and nothing about the object merge applies to it; that fault and its fix are covered in when an HMI model is missing from the programming software.
What do you do next time an object seems missing? #
Run three checks in order: search the Object List by function, take the merged item and set its behaviour in the configuration dialog, and only then treat the software itself as suspect. The decision for each case:
- A familiar name is gone and a combined item sits in its place: use the combined item. For the numeric pair that is Numeric Entry/Display, with entry or display chosen by its behaviour selector.
- You cannot spot the replacement: type the function into the search bar at the top of the Object List and let the filter take you to the object that performs it.
- The screen was built before the merge: change nothing. Placed objects keep working on their stored settings, and only new placements come from the merged item.
- The list is empty, will not populate, or the panel model itself is missing: the merge is not the cause. Troubleshoot the installation or the model list instead of the objects.
Questions asked
Will a project built before the merge still open and run?
Yes. Placed objects carry the behaviour stored in their own configuration, so the project opens and runs as built; only the palette for new objects changed. When you later edit one of those placements, you work through the same configuration dialog and the same behaviour selector the merged item uses, because the combined item is that object under its new single name.
Where are the combined objects officially listed?
In the software release notes for the version you install. The C-more EA9 firmware history refers you to the release notes for the same version, and those notes are the record of which items were combined and what else changed. Check them for the exact version before assuming a name is gone for good.
What is the difference between the Object List and the online library?
The Object List is built into the programming software and holds the objects you drag onto the workspace to create screens. The online library is a separate collection of graphics, objects, whole screens and example projects that you import into a project; after import, those items are used from within the programming software like anything else you added yourself.
Can you use ready-made parts instead of the merged default objects?
Yes. Besides the default objects, the software provides ready-made parts, which are preconfigured versions of the default objects, so a part can give you a numeric entry or display already set up. You drag and drop them into a project exactly like a default object.