Troubleshooting
Why TIA Portal V20 finds 0 compatible Unified Comfort panels
Short answer
The '0 compatible devices' scan and the 8020AB0019A5FFF4 load error both come from one gap: the WinCC Unified support in TIA Portal V20, the project's HMI device version and the panel image are not all V20. Install the V20 update, set the device version to 20.0.0.2, flash Panel Image V20, and load with the interface set to Ethernet and the panel's IP entered directly.
On this page
- Why does TIA Portal V20 find 0 compatible devices?
- What does communication error 8020AB0019A5FFF4 mean?
- Which three versions have to match for a V20 Unified load?
- How do you install the V20 update and set the device version?
- How do you flash Panel Image V20 on the panel?
- How do you load the project once the versions match?
- What do you check if the scan still shows 0 compatible devices?
- How do you confirm the transfer is good?
- Questions asked
A Unified Comfort Panel that answers ping, shows up under accessible devices, and still ends the scan with "0 compatible devices of 1 accessible devices found" is not a network fault. The engineering station cannot offer that panel a load because the WinCC Unified support in TIA Portal V20, the HMI device version in the project and the image on the panel are not all in the V20 generation. The same gap is what later aborts the load with communication error 8020AB0019A5FFF4. The fix runs in a fixed order: install the V20 update, raise the device version to 20.0.0.x, flash Panel Image V20, then load by IP address.
Why does TIA Portal V20 find 0 compatible devices? #
The scan rejects the panel because no installed device package and image pair can serve it: accessible means the panel answered on Ethernet, compatible means your installation can generate a load for that exact type and version, and out of the box V20 cannot. The two scan lines in this field pattern locate the fault precisely. "Found accessible device hmi_4.profinet interface_gbit" proves the whole IP path — cabling, subnet, adapter choice and any firewall — because the panel answered and reported its PROFINET interface. "Scan completed. 0 compatible devices of 1 accessible devices found" then rejects that one reachable candidate in the compatibility filter, not on the network.
That filter compares three things:
- The panel type and image generation the target reports about itself.
- The device versions your installation can compile for, from the WinCC Unified support it carries.
- The image files the transfer needs on the engineering station.
That is why the usual network moves change nothing. Ping already answered, USB and direct Ethernet return the same two lines, and "Reset to factory settings" touches none of the three items above. Until the station carries the V20 device package and the panel carries a V20 image, the scan has nothing compatible to offer and correctly reports zero.
What does communication error 8020AB0019A5FFF4 mean? #
8020AB0019A5FFF4 is the same version gap caught one step later: the load session reaches the panel, then aborts because data matching the V20 project is missing on the engineering station or on the panel image — it is not a transport failure. The sequence in the field case is itself diagnostic: the code appeared only after "Type of PG/PC interface" was set to "Ethernet" with "Use other IP" and the panel's project address, so the session got far enough to start a transfer. When the transport is proven and the load still aborts, the missing piece is transfer data for the V20 project, and four questions settle it:
- Is a V20 update installed for the TIA Portal?
- Which device version is selected for the HMI station in the project?
- Which image version is installed on the panel?
- Are the panel images for V20 for the Unified Comfort Panels installed on the engineering station?
Any "no" or any pre-V20 answer produces exactly this error. Do not confuse it with the Comfort-panel family: a TP700 that pings but will not load and throws 0132:000002 fails for a different reason, covered in why a TP700 Comfort download fails 0132:000002 despite ping.
Which three versions have to match for a V20 Unified load? #
Three layers must sit in the V20 generation together: the WinCC Unified support installed with your TIA Portal V20, the device version of the HMI station in the project, and the image running on the panel — one V19 anywhere and the load fails.
| Layer | What it is | What V20 requires |
|---|---|---|
| Engineering station | TIA Portal V20 with its WinCC Unified update | The V20 update installed, so device version 20.0.0.2 becomes selectable |
| Project | Device version of the Unified Comfort Panel station | 20.0.0.2, or the highest 20.0.0.x the update installed |
| Panel | The runtime image on the device | Panel Image V20, or a newer V20 update image |
The image is allowed to trail the TIA update by a documented step, never by a major version. The Siemens image-download entry for Unified Comfort Panels records that the features of TIA Portal V20 Update 1 are already available with Panel Image V20, and that the features of TIA Portal V20 Update 5 are already available with Panel Image V20 Update 4, and calls both pairings compatible. Read plainly: keep the panel on the newest V20 image published, treat any image older than V20 as incompatible with a V20 project, and expect the project's device version to be limited to what the station has installed.
How do you install the V20 update and set the device version? #
Install the V20 update on the engineering station first, then raise the HMI station's device version to 20.0.0.2 and recompile — done in the other order, the version list will not offer the new device version at all.
- Close TIA Portal, download the update for TIA Portal V20 from Siemens Industry Online Support — a separate download from the V20 installation media — and run it with administrator rights on the engineering PC.
- Reopen the project in the updated V20.
- Right-click the Unified Comfort Panel station, choose "Change device / version", select 20.0.0.2 or the highest 20.0.0.x offered, and confirm. If 20.0.0.2 is missing from the list, the update did not land; reinstall it before touching the panel.
- Recompile the station (software, rebuild all) — the compile produces the V20 payload the image will be asked to accept.
How do you flash Panel Image V20 on the panel? #
Flash from USB using the image from Siemens' entry "Image downloads for SIMATIC HMI Operator Panels: Unified Comfort Panels", applied through the panel's Control Panel under Service and Commissioning → Update OS; the panel reboots into V20.
- Download Panel Image V20 for your panel from that entry; the general image-download entry for HMI operator panels points to the same page.
- Copy the image files to a USB stick formatted FAT32.
- On the panel, open Control Panel → Service and Commissioning → Update OS, select the V20 image and apply it.
- Let the panel reboot, then read the image version it reports — it must now say V20.
Do the flash with the machine in a safe state: the panel is offline and reboots during the update, so anything it displays or controls is down meanwhile. If the panel then sits in maintenance mode instead of starting, follow the steps in Unified Comfort panel maintenance mode reboot loop.
How do you load the project once the versions match? #
Load by address instead of by scan: set "Type of PG/PC interface" to "Ethernet", select "Use other IP" and enter the panel's project address, and put the engineering PC in the same subnet — with the panel at 192.168.0.10/24, the PC takes an address like 192.168.0.5/24.
The subnet arithmetic for that example: 192.168.0.10 AND 255.255.255.0 gives 192.168.0.0, and 192.168.0.5 AND 255.255.255.0 also gives 192.168.0.0, so both sit on the same network and a direct cable or a single switch carries the load with no router involved. On a direct link like that, a ping round trip under 1 ms is normal.
Start search now has something to offer: the scan lists the panel as a compatible device. Select it, press "Load", confirm the preview, and let the panel restart into the runtime. If the transfer instead fails while the panel waits in Initial Start Mode, that is a different fault with its own fix, covered in why an HMI transfer fails in Initial Start Mode despite ping.
What do you check if the scan still shows 0 compatible devices? #
Check the three layers in order — the update installed with 20.0.0.2 selectable, the panel reporting image V20, and the project opened in the updated V20 — because with all three true the scan lists the panel, and anything left is a network fault with a different signature.
- Open "Change device / version" again: if 20.0.0.2 is not in the list, either the update is not installed or the project was opened in an older, parallel TIA Portal installation — close it and open the updated V20.
- Read the image version on the panel's Control Panel: anything older than V20 stays incompatible regardless of what the station carries. Flash V20 first, then rescan.
- Count the adapters: with several network adapters, a VPN client or a bridged connection, the subnet scan can leave through the wrong interface. Force the load path by address with "Use other IP" instead of rescanning.
- Ping the panel from the engineering PC: if that fails, the fault has moved from versions to the network, and no update will fix it — correct cabling, subnet or firewall first, then return to the scan.
How do you confirm the transfer is good? #
Confirm three results: the scan lists the panel as a compatible device, the load preview completes with 0 errors, and the panel boots into the configured start screen within roughly 45 to 90 seconds of the transfer finishing.
- The panel's Control Panel reports image version V20, the same generation the station compiled.
- A tag triggered from a screen arrives in the PLC, which proves the runtime is serving, not just booted.
- The next scan from the same station reports the panel compatible on the first pass — keep that as the reference behavior for the next project.
Questions asked
Does 'Reset to factory settings' help when the scan finds no compatible device?
No. The reset deletes the project and settings from the panel but keeps its installed image, and it changes nothing on the engineering station. The version mismatch survives untouched, so the panel comes back with no project and the same scan result. Flash Panel Image V20 instead.
Does transferring over USB skip the version check?
No. USB only changes the transport. The compatible-device handshake and the check behind error 8020AB0019A5FFF4 run after the connection is established, on any path, which is why the subnet scan, direct Ethernet and USB all return the same result until the three versions match.
Where do you download Panel Image V20?
From Siemens Industry Online Support entry 109825605, 'Image downloads for SIMATIC HMI Operator Panels: Unified Comfort Panels'. The general 'Image Downloads for HMI Operator Panels' entry 109746530 points to the same page. It is a separate download from the TIA Portal V20 update: one fixes the panel, the other the engineering station.
Does a WinCC Unified PC runtime need the same version match?
Yes, on the version side. Device version 20.0.0.2 exists for Unified PC as well as Unified panels, so a PC station must run the V20 generation of the WinCC Unified runtime to accept a V20 project. Only the repair differs: the PC gets a runtime setup or update instead of a flashed panel image.