Why WinCC Advanced looks gone in TIA Portal V18
Short answer
WinCC Advanced still ships in TIA Portal V18; only the classic device list is frozen, so you configure Comfort and Advanced panels as V17 device versions and lose nothing on existing projects. WinCC Unified, the web-based successor line, is where new device development goes, and new projects should plan for it.

On this page
- Is WinCC Advanced gone from TIA Portal V18?
- Why does TIA Portal V18 add no new device version for Comfort and Advanced panels?
- Can TIA Portal V18 still service my existing Comfort and Advanced projects?
- What is WinCC Unified and when did it arrive?
- Do I have to learn HTML5 to program WinCC Unified screens?
- Does my WinCC Advanced license still cover TIA Portal V18?
- Should I start new work on WinCC Advanced or WinCC Unified?
- Questions asked
The worry that WinCC Advanced disappeared in TIA Portal V18 has a short answer: it did not. WinCC Basic, Comfort, Advanced and Professional ship as engineering options in V18; what V18 did not add is a new device version for the classic panels, so every classic Comfort, Advanced or Basic panel in a V18 project is created at its V17 device version. The device catalog looks frozen because it is frozen — the engineering tools were not removed. WinCC Unified, shipping since TIA Portal V16, is the line where new devices and new features land. This article separates the two decisions that follow: how to keep servicing a classic installation under V18 tooling, and when a project belongs on Unified instead.
Is WinCC Advanced gone from TIA Portal V18? #
No — WinCC Basic, Comfort, Advanced and Professional all still ship as engineering options in TIA Portal V18, and the V18 update packages and the licensing documentation both list them as V18.x products, so nothing was pulled from the installer.
The confusion comes from reading the HMI device catalog as the product list. The engineering options are part of the V18 installation; what the catalog no longer does is grow. When you add an HMI device in a V18 project, the classic entries are the same ones you picked in V17, because no new classic panel definitions were introduced. The product was not removed — its device list was closed. That distinction decides everything downstream: the tools to open, edit, compile and download a classic HMI project are present in the V18 install, and the only thing missing is new classic hardware definitions.
Why does TIA Portal V18 add no new device version for Comfort and Advanced panels? #
TIA Portal V18 ships the classic Comfort and Advanced device catalog unchanged, so every classic panel you add is created at its V17 device version — the engineering release moved to V18 while the classic device definitions stayed at V17.
Device version and engineering version are two different numbers. The engineering version is the TIA Portal release installed on your station; the device version is the definition of a specific panel model that this release can configure. From V18 on, development concentrates on the Unified device range and the classic device definitions stay at their last state, which the V18 release documentation states plainly: classic devices are created as V17 device versions. In practice, the device version column for a classic panel in a V18 project reading V17 is the correct entry — not an installation fault, and not something a setting will change, because the newer classic definitions do not exist to reveal.
What pairing of engineering version and device version actually works? #
One pairing is documented and one pairing fails at device selection. The example uses a TP1200 Comfort; the model number only stands in for whichever classic panel your project carries.
- Engineering installation: TIA Portal V18, engineering version 18
- HMI device in the project: classic Comfort panel at device version V17, value 17
- Panel image on the device: the matching V17 image, value 17
The pairing checks out: 17 ≤ 18, so the V18 engineering station accepts the device, compiles the project and downloads to the panel running the V17 image — exactly the combination the V18 release documentation describes. Change one line and it breaks: ask the catalog for device version 18 on the same classic panel and there is no such entry to select, because V18 introduced none. The decision is to keep the 17 and read it as correct, not as an error awaiting a fix.
Can TIA Portal V18 still service my existing Comfort and Advanced projects? #
Yes — a project carried forward opens with the classic panel still set to its V17 device version, compiles under V18 and downloads to the panel, and the image download tool for Basic, Comfort and Mobile panels supports TIA Portal V18 and all subsequent versions.
Servicing splits into three jobs, and all three still work. Opening and editing: the project loads with the classic panel at its frozen device version, and screens, tags, alarms and connections edit as they did before. Compiling and downloading: the V18 station compiles the classic device and transfers to the panel. Panel images: the image installation tool covers V18 and later, so re-flashing or replacing a classic panel does not strand you on an old engineering station. What servicing does not bring is new classic functionality, because that device line is closed. A panel that runs today keeps running under V18 tooling.
What is WinCC Unified and when did it arrive? #
WinCC Unified is the long-term successor line, built on web technology and shipping since TIA Portal V16, scaling from visualization served from the PLC itself (View of Things) up through Unified Comfort Panels to Unified PC runtime for SCADA-class stations.
Unified is not a renamed Advanced; it is a second runtime line covering the whole visualization range from one engineering platform. The panel end is the Unified Comfort Panels family — the first base variants arrived in September 2020, and the Hygienic, Pro and Basic variants followed — while the PC end is Unified PC runtime for PC and SCADA-class stations. This is the line that receives new device versions, which is precisely why the classic catalog beside it looks frozen: the new panels engineers hear announced are Unified hardware.
Two structural differences matter to a classic programmer. The visualization reaches its clients through a browser over HTTPS, and the certificates behind that trust become a maintenance item for the life of the station — the walkthrough of long-term HTTPS certificate replacement on industrial controllers shows what that renewal routine involves. And on the panel end, the device version configured in the project and the image installed on the panel are two separate numbers to keep straight; the article on device version vs panel OS image on Unified Comfort Panels shows where each lives and how they fall out of step.
Do I have to learn HTML5 to program WinCC Unified screens? #
No — you engineer Unified screens graphically in the TIA Portal editor the same way you engineer classic screens, placing controls, binding tags and configuring alarms, and HTML5 only matters if you choose to build your own custom controls with web technology.
The screens stay inside the editor: you work with the configured control set, bind controls to tags and set up alarms the way you always have, and ordinary machine visualization never touches a line of HTML. Web technology becomes relevant only where you deliberately author custom controls, which the open platform permits and the workflow does not require.
The skill that does not carry over is scripting. Classic WinCC scripts run in VBScript; Unified runtime scripts are written in JavaScript, so VBScript routines are rewritten in the new language during a migration. Inventory how much script logic a classic application carries before deciding anything, because script-heavy screens bring real rewrite effort into a Unified conversion; the article on what Visual Basic can and cannot do inside a WinCC project maps where those scripts sit and what they do.
Does my WinCC Advanced license still cover TIA Portal V18? #
Yes — the licensing documentation for STEP 7 and WinCC in TIA Portal lists WinCC Basic, Comfort, Advanced and Professional as V18.x options, so the classic line is still a licensed product family at V18, not an entry the authorization scheme abandoned.
The part with its own rules is which license key carries across which version boundary. Engineering authorizations, upgrades and runtime licenses move differently, and the breakdown of WinCC option licenses that carry over across TIA Portal versions lists the pairs explicitly. Treat that check license by license: an option that upgrades cleanly at one version boundary can behave differently at the next, so each key is verified against the version pair it must survive rather than assumed from the product line.
Should I start new work on WinCC Advanced or WinCC Unified? #
Keep an existing Comfort or Advanced installation classic — configure its panels as V17 device versions in V18 — and plan every new operator station, new panel model or missing feature on WinCC Unified, because the classic device line is closed and Unified is where new devices appear.
Commit by case rather than by preference:
| Situation | Where the work belongs | Why |
|---|---|---|
| Existing Comfort or Advanced project needs edits, a new screen or a replacement panel | Classic, engineered in V18 at the frozen device version | Engineering options, licensing and image downloads all support V18 |
| Operator logic lives in VBScript | Classic, until a migration budget exists | Unified scripting is JavaScript, so those routines are rewritten |
| A new operator station, or a panel model that exists only as Unified hardware | Unified | New device versions arrive on the Unified line |
| Several viewers need the same visualization in a browser | Unified | The web delivery model is built for browser clients |
| A PC at the machine runs the HMI | Unified PC runtime on PC hardware | The runtime is PC software, so the station is specified as PC hardware |
That last row is a hardware specification as much as a software one: Unified PC runtime runs on a touchscreen computer mounted at the machine, which puts the choice in the territory of industrial panel PCs rather than a desktop tower beside the cabinet.
The one-line decision: a classic installation stays classic and services cleanly under V18 tooling; anything genuinely new — a new panel, a new station, a capability the classic line never had — is planned on WinCC Unified, which has been the successor since V16 and is the catalog that actually grows.
Questions asked
Can a Comfort or Advanced license open a WinCC Unified project?
No. Unified is licensed as its own family, separate from the classic Basic, Comfort, Advanced and Professional options, so a classic authorization neither opens a Unified project in engineering nor runs one at runtime. Before converting anything, establish which Unified license the engineering station needs and which license each runtime target needs, and treat the two families as independent budgets even inside one TIA Portal installation.
What is View of Things used for?
It is the lightweight end of the Unified range, meant for small applications where a dedicated panel or PC station would be overkill: the visualization runs from the PLC itself rather than on a separate panel or PC station. When the application outgrows it, the same Unified engineering platform scales up to Unified Comfort Panels and to Unified PC runtime, so the work done in the one tool family is not discarded.
Do VBScript routines convert automatically to Unified?
No. Unified replaced VBScript with JavaScript, and the old routines are not translated automatically; each one is reworked in the new language during a migration. Weight any migration estimate by how heavily the classic application scripts its operator side — display switching, interlocks and data handling written in VBScript are the expensive part of the conversion, while screens that barely use scripts convert with far less scripting effort.
Does a Unified PC runtime have to match the engineering version?
Yes, and this is where Unified is stricter than the classic line: the runtime installed on a Unified PC station has to be the version the engineering project expects, so a station left on an older runtime blocks the download until that runtime is updated. Classic panels sidestep this in V18 because the frozen V17 device version is the defined configuration, not a mismatch to repair.