Troubleshooting
Why the Transfer entry disappears from WinCC flexible 2008
Short answer
A Start Center without its Transfer entry has lost part of its action registration, usually after an interrupted update. Right-click the Start Center icon in the Windows notification area, run Reset SIMATIC WinCC flexible (about 10 to 30 seconds) and reopen the tool; Transfer returns. If the reset entry is greyed out, the installation record is damaged: re-run the installed service pack's setup as an update, then reset.

On this page
The Transfer entry disappears because the Start Center's action registration — data written at installation and rewritten with every service pack — has been damaged, typically by an interrupted update, a hard shutdown while the tool was writing its configuration, or antivirus software quarantining tool components. Your project did not break; the launcher lost one entry. The documented fix takes about 10 to 30 seconds: right-click the Start Center icon in the Windows notification area, click "Reset SIMATIC WinCC flexible", wait for the process to finish and open the tool again. If that reset entry shows up greyed out, the installation record behind it is broken, and the repair is to re-run the setup of the installed service pack as an update before resetting.
What the missing entry means #
The Start Center builds the project column from registration data written at installation and updated with every service pack. When that data is corrupted, the column renders normally except for the actions whose registrations were lost — Transfer is the one you notice first, because nothing reaches the panel without it.
The damage typically arrives one of three ways: a service pack or update install that was interrupted, a hard shutdown while the tool was writing its configuration, or antivirus software quarantining tool components. The same damage can also remove the loading icon from the notification area, so glance at the bottom right of the taskbar: a missing loading icon next to a missing Transfer entry confirms this fault and rules out a project problem.
The reset that restores Transfer #
Work through the tray icon; the procedure is six steps:
- Close every WinCC flexible window, editors and Start Center windows alike.
- Find the Start Center icon in the Windows notification area, at the bottom right of the taskbar.
- Right-click that icon to open its context menu.
- Click "Reset SIMATIC WinCC flexible".
- Confirm and let the process run until it reports completion; do not reopen the tool while it works.
- Open WinCC flexible again and check two things: the loading icon is back in the notification area, and Transfer appears in the project column.
This is the manufacturer's documented way to return the tool to the original status of the last installation, published as Siemens support entry 36645252. It rebuilds the registration the Start Center reads, which is exactly why the lost action returns.
Worked example: a 2008 SP5 station that lost its Transfer entry #
Inputs, with where each one comes from:
- Tool version: WinCC flexible 2008 SP5, the version this fault appears on.
- Symptom: the project column shows its other actions but no Transfer entry.
- Tray: the Start Center icon is present in the notification area, so the reset route is open.
- Reset runtime: 10 to 30 seconds, the typical window for the tray reset.
The rule, in words: the tray reset returns the tool to the original status of the last installation, re-registering the Start Center's actions — Transfer included — from the record that installation left behind.
The arithmetic: the window runs from 10 s to 30 s, a spread of 30 s − 10 s = 20 s. Budget the upper bound — 30 s after you confirm, the reset is finished, and the pass/fail check is one look at the project column plus one at the notification area.
The result: the project column lists Transfer again, with the loading icon back in its corner of the tray, and the station returns to service with nothing recompiled and nothing re-transferred.
The decision for each case:
- Transfer present: done — run the transfer you were trying to start.
- The reset entry greyed out: the installation record is damaged, so run the update below before anything else.
- Reset ran but Transfer still missing: apply the same service pack update, then reset once more; if the entry is still absent after that, reinstall the tool from its installation media.
When the reset entry is greyed out #
A greyed-out "Reset SIMATIC WinCC flexible" is a diagnosis by itself. The reset rebuilds from the record the last installation left behind; when that record is damaged there is nothing to reset to, and the menu shows the entry as unavailable. The repair is to start the setup of the service pack already installed and take its path for updating the existing installation:
- Run the setup from local media or a local copy, not from a network share.
- Let it run to completion; an interrupted update is one of the ways this record gets damaged in the first place.
- Restart the PC when the setup asks for it.
- Open the Start Center and check for Transfer, and run the tray reset once more if the column still looks short.
Leave the registry alone — the setup is the tool that rebuilds the record correctly, and hand edits there put the license at risk rather than the fault. If Transfer is still absent after the update and one more reset, reinstall the engineering tool from its original media.
When the tray icon is missing too #
If the notification area holds no Start Center icon at all, the same support entry documents a manual start: close WinCC flexible, then end the two processes "Hmies.exe" and "HmiSmartStart.exe" in Task Manager. It then walks through the folders it clears, written per Windows version — take those folders from the entry itself rather than deleting profile directories by guesswork. With the processes ended and the entry's steps done, start the tool; when the Start Center icon reappears, finish with the tray reset.
Proving the fix before the next transfer #
Check the repair against the Start Center before you trust it with a production download:
- The loading icon is present in the notification area.
- Transfer sits in the project column with the other actions.
- The project compiles, and the transfer starts with the panel selected as target.
If the entry is back but the download fails the moment it begins, the fault has moved into the connection and away from the Start Center; for one common panel the causes are collected in why a WinCC Flexible transfer to a TP177B PN/DP fails instantly. Transfers over the serial adapter fail for their own reasons, worked through in why a PC Adapter cannot download WinCC Flexible to a TP177.
Questions asked
Do I have to restart the PC before running the reset?
No. A restart is the safest variant because it releases every file the tool still holds open, but the reset does not depend on it. The minimum is closing all WinCC flexible windows first; if the context menu offers the reset entry, it runs without a restart. Restart anyway if the tool was killed hard or the station has run for weeks.
Does the reset delete my projects or the images on the panel?
No. The reset rebuilds only the Start Center's registration and the user configuration the tool keeps for itself. Project folders on the station, compiled images and the runtime already loaded on the panel are outside what it touches, so nothing of yours is deleted.
Will the reset cost me a license activation?
No. The reset rebuilds configuration, not licensing: the license keys stay in place and the tool comes back exactly as licensed before. A license or demo message that appears later at runtime on the panel has its own cause on the runtime side and is not a consequence of this reset.
How do I keep the Transfer entry from disappearing again?
Finish what you start: let every service pack and update setup run to completion, and never shut the station down while a setup is still writing. Give the tool's install folder an exception in the antivirus scanner so its components are not quarantined. A station that has run for weeks needs a clean shutdown before any update.