Explainer

WinCC V13 tutorials: the documentation that matches your edition

HMI and touchscreens Published 7 min read By IMDTouch engineering team

Short answer

Skip generic books. Use the version-matched Getting Started manuals, the V12 color-mixing-station example and the official demo projects — after pinning down four things: your WinCC edition (Basic, Comfort, Advanced or Professional), your runtime target, whether you run V13 or V13 SP1, and whether the example was built for V12.

On this page
  1. Pin down four things before any tutorial
  2. The V13 SP1 manuals, edition by edition
  3. The V12 examples and what to take from them
  4. A worked match from station to material
  5. Work one project end to end
  6. Scripts and reusable objects, after the base runs
  7. When the tutorial and your station disagree
  8. Questions asked

For practical WinCC V13 work, skip the hunt for a book and take the version-matched documentation set instead: the Getting Started manual for your edition, the interactive color-mixing-station example, and the official demo projects, worked one small project at a time. Books freeze at one release; these documents are keyed to exact versions — WinCC Basic V13.0 SP1 and WinCC Professional V13.0 SP1 both have one — so you can match the material to what your station actually runs. Before you open any of it, pin down four things: the engineering edition installed (Basic, Comfort, Advanced or Professional), the runtime target (Basic Panels, Comfort Panels, WinCC Runtime Advanced or the Professional PC runtime), whether the station runs V13 or V13 SP1, and whether the example you are reading was built for V12. Those four answers decide which manual fits, what to take from the V12 examples and what to rebuild.

Pin down four things before any tutorial #

WinCC V13 is a family, not one product. The four WinCC editions inside TIA Portal expose different editors, objects and scripting options, and they serve different runtime targets, so a tutorial can show valid menus and still lead you somewhere your edition cannot go. Answer the four questions in order; each one cuts the material list.

What you check The decision it drives Where the answer lives
Engineering edition Which manuals, editors and objects exist on your station The installed-product information TIA Portal shows
Runtime target Whether the example's screens and objects deploy to your hardware The device configured in the project
V13 or V13 SP1 Which document revision matches the menus you see The service pack level of the installed products
Example's release Whether you read the example as a pattern or migrate it first The prerequisites stated with the example

Read the editions against their targets like this. WinCC Basic engineers the Basic Panel family only. WinCC Comfort and WinCC Advanced both engineer Comfort Panels; Advanced additionally engineers PC stations that run WinCC Runtime Advanced. WinCC Professional serves the PC runtime for SCADA-scale projects and does not configure panel projects — a Unified Comfort Panel, for example, sits outside Professional's reach.

Decision: a project aimed at a Comfort Panel takes the Comfort or Advanced Getting Started set — not the WinCC Basic first-steps manual and not the Professional one.

The V13 SP1 manuals, edition by edition #

For WinCC Basic, start with First steps - WinCC Basic V13.0 SP1, entry 109082860 on the Siemens industry support portal. It gives the system overview of STEP 7 and WinCC, an introduction to the TIA Portal and the Getting Started documentation — exactly the on-ramp a Basic edition station needs.

For WinCC Professional, take Getting Started Documentation - WinCC Professional V13.0 SP1, entry 109096785. Its instructions show step by step how to create a project in the TIA Portal, which is the practical start a Professional PC station needs.

Comfort and Advanced have the same style of Getting Started set for V13 SP1 on the same portal — the titles name the edition and the service pack, in the form of a Getting Started WinCC Comfort V13.0 SP1 or a Getting Started WinCC Advanced V13.0 SP1 set. Search the portal with your edition name plus the service pack rather than trusting a reprint of unknown origin. Match the service pack, not just the major version: on a station running V13 SP1, the V13 SP1 documents match the menus you actually see. For the wider question of which release to standardize on at all, the article why no WinCC version is bug-free and which one to pick works through that trade-off.

Decision: one manual per station — the Getting Started whose title names your edition and its exact service pack.

The V12 examples and what to take from them #

The interactive Getting Started color-mixing-station example was built for WinCC in TIA Portal V12 and covers panels, Advanced and Professional. In a V13 SP1 station its value is the pattern: a connected tag set driving screens around one small process, with alarms and operator commands on real objects. Work it in your own edition — rebuild the steps deliberately instead of expecting the V12 files to drop in unchanged.

The demo projects under entry 73468169 — Demo projects for HMI Panels at WinCC V12 (TIA Portal) for Basic Panels, Comfort Panels and WinCC Runtime Advanced V12 (TIA Portal) — are complete panel projects to dissect. Migrate a copy into your station, keep the original archive untouched, compile, and read every change the migration reports before you reuse a screen or faceplate. The working method is the one Learning advanced HMI features from demo projects describes.

Decision: V12 material teaches design patterns; the V13 SP1 manuals give exact menus. Never copy a V12 screen into V13 without migrating and compiling it.

A worked match from station to material #

Example station: TIA Portal V13 SP1 installed with WinCC Advanced V13.0 SP1, and the project's device set to a Comfort Panel. The four answers: edition = WinCC Advanced; target = Comfort Panel; service pack = SP1; example releases = V12 (color-mixing station and demo projects).

The decisions follow directly: use the Advanced V13.0 SP1 Getting Started set for menu-accurate steps; take the Comfort Panels scope of the demo projects under entry 73468169 and migrate a copy rather than opening the originals; work the V12 color-mixing-station example as a pattern only; and skip entry 109096785, because the Professional manual targets the Professional PC runtime, which this station does not have. The first document to open is the Advanced Getting Started set; the first thing to build is the end-to-end project in the next section.

Work one project end to end #

A tutorial pays off when it exercises the complete signal path, so build one small process — a tank, a conveyor station, a mixer — in this order:

  1. Define the target: create the device your edition supports, a Comfort Panel under Comfort or Advanced, or a PC station running WinCC Runtime Advanced.
  2. Connect the controller and confirm live values before any graphics work; a screen you cannot feed is decoration.
  3. Build a small tag set: one Boolean status, one operator command, one analog process value and one setpoint, each with its read or write direction noted.
  4. Create three screens — overview, equipment detail, diagnostics — on a consistent home-and-back navigation pattern.
  5. Dynamize objects: bind status color, visibility and the numeric display to those tags, and give every visual state an intentional meaning.
  6. Add one alarm: trigger a known condition, display the message, acknowledge it, and verify the state clears when the condition does.
  7. Compile, then simulate: clear the compile errors, run the simulation and exercise every tag and screen. First runs belong in simulation or on a bench controller, never on a machine that is producing.
  8. Download last, and record the target type and software version with the project archive.

The discipline is not WinCC-specific: working a Getting Started tutorial end to end is the same habit behind configuring the Power PMAC IDE with Getting Started tutorials on a motion controller.

Decision: one finished project that runs teaches more than any chapter list — finish it before adding reusable graphics or scripts.

Scripts and reusable objects, after the base runs #

Once the base project runs, study the reuse features one at a time. A template standardizes persistent layout and navigation. A faceplate encapsulates one equipment graphic together with its tag interface, so ten pumps need one drawing and ten instances. Pop-up and slide-in screens expose detail without permanently occupying process-screen space. Keep equipment-specific tags outside the reusable object and pass in only the values and commands it needs; that separation is what keeps later graphic changes consistent across instances.

Reach for VBS only where standard dynamics, events or controller logic cannot express the requirement cleanly, and only after confirming the configured runtime target supports scripts. The permitted scope of scripting is narrower than most beginners expect; What Visual Basic can and cannot do inside a WinCC project sets that boundary out before the first script.

Decision: standard object dynamics first, scripts last, and scripts only on a target that runs them.

When the tutorial and your station disagree #

  • A menu, editor or object from the tutorial is missing. The tutorial targets another edition or service pack. Compare its stated prerequisites with the installed products and the configured device before treating it as a fault.
  • The demo project will not open. It was delivered for another release. Migrate a copy, compile it and review the reported changes; never overwrite the original archive.
  • An animation works in simulation but not on the panel. The target did not receive the current build, or its connection differs from the simulated one. Verify the download and watch live tag values on the diagnostics screen.
  • A button changes on screen but the machine ignores it. The HMI event fired, but the command path or the controller acknowledgment failed. Watch the command tag and the separate feedback tag at the controller before calling the panel faulty.

Decision: settle edition, service pack and target first; call behavior a fault only when all three match.

Questions asked

Do I still need a printed WinCC book?

A book can still explain concepts, but it freezes at one release, while the support-portal documents are keyed to exact versions and searchable by entry number. For practical project work the portal material wins because you can match it to what your station actually runs. Treat any book as background reading, and check its menus against your installed service pack before trusting a step.

Will the V12 demo projects open in my V13 SP1 station?

Not as originals. They are delivered for WinCC V12 targets — Basic Panels, Comfort Panels and WinCC Runtime Advanced V12 — under entry 73468169. Open a migrated copy in your V13 SP1 station: keep the original archive untouched, compile the migrated project, and read every change the migration reports before you reuse a screen or faceplate from it.

What is the difference between WinCC Runtime Advanced and WinCC Professional?

WinCC Advanced engineers panel projects and PC stations that run WinCC Runtime Advanced. WinCC Professional is the PC SCADA edition with its own separate runtime, documented under Getting Started entry 109096785, and it does not configure panel projects. The engineering edition and the runtime target are both chosen when you create the device, so a Professional license alone does not convert a panel project.

Can I learn WinCC scripting from the Getting Started manuals?

Only as a first look. The Getting Started manuals get a base project running without scripts, so treat scripting as a second pass: learn the standard dynamics first, then study VBS where standard dynamics, events or controller logic fall short. Mind the target too — WinCC Basic panels do not run VB scripts, so scripting practice belongs on a Comfort Panel or a WinCC Runtime Advanced station.

Keep reading

  • Troubleshooting

    Why Installing WinCC Flexible Breaks TIA Portal V13

    No — TIA Portal V13 does not bundle WinCC Flexible; the Root Screen editor you already opened is its integrated WinCC editor, and that is where KTP panels are engineered. WinCC Flexible 2008 is the separate previous-generation tool, and installing it on the V13 machine is what stops TIA Portal starting, so uninstall it, run the V13 repair, and keep the two tools on separate machines or migrate the project.

    HMI and touchscreens

  • Troubleshooting

    Why WinCC 7.2 fails on new project creation

    A WinCC 7.2 project-creation failure is an engineering-tool problem on the engineering PC, not a runtime communication fault. Fix it by verifying the Windows prerequisites WinCC 7.2 requires: MS Message Queuing installed and running, English regional and language settings, an administrator launch of WinCC Explorer, and a writable project folder.

    HMI and touchscreens

  • How-to

    SIWAREX HMI example projects for WinCC Professional

    Yes: the vendor's SIWAREX FAQ lists an example for PC-based WinCC next to the TP700 Comfort Panel project, and a WP351 example exists for WinCC Unified. Qualify the download against three documented facts — engineering tool and version, runtime target, SIWAREX model — then carry its weighing functions across through one verified path: module to CPU1214, CPU1214 to the 1513, 1513 to HMI external tags, rebound from a mapping list.

    HMI and touchscreens

Set an Idle Screen Timeout That Returns to the Main Page