Why WinCC Runtime Professional Asia uses the standard upgrade path

HMI and touchscreens Published 6 min read

Short answer

WinCC Runtime Professional Asia licenses take the same upgrades as the standard licenses. Only three fields decide the order line: the target WinCC version, the PowerTag count of the existing license, and the delivery form, download or DVD plus USB stick. In the Siemens Industry Mall, leave the version filter off WinCC ASIA or the shared upgrade entries disappear from the results.

On this page
  1. One upgrade family, not an Asia variant
  2. Identify the existing license before you search
  3. Field one: the target WinCC version
  4. Field two: the PowerTag count of the existing license
  5. Field three: delivery form
  6. Searching the Industry Mall without hiding the upgrades
  7. Worked example: a V17 line moved to V19
  8. Before you place the order
  9. Questions asked

WinCC Runtime Professional Asia licenses take the same upgrades as the standard, non-Asia licenses. The selection is decided by three fields only: the WinCC version you are moving to, the PowerTag count of the existing license, and the delivery form, download or DVD plus USB stick. Whether the license is Asia or not-Asia is not one of those fields, even though the upgrade descriptions carry no Asia wording at all. One catalog trap to know before you search: in the Siemens Industry Mall, the version filter must be left off WinCC ASIA, because that filter setting hides the shared upgrade entries from the results.

One upgrade family, not an Asia variant #

The Asia designation changes the market and the language scope of the product, not the upgrade logic. The upgrade order lines are shared: an Asia Runtime Professional license is upgraded with the same catalog items as any standard Runtime Professional license, and the absence of Asia wording in the upgrade text is expected, not a sign you are looking at the wrong item.

Treat this as a license-selection task before it is a software-installation task. An upgrade entitlement authorizes the transition from an existing license to a new version; it does not by itself establish that the target runtime will be compatible with your runtime computer or your migrated project. That is the same distinction between an entitlement and installed software covered in does a WinCC Professional entry mean SCADA runtime is installed.

Record four things from the purchase documentation and the Siemens licensing tools: the full product designation, the licensed version, the PowerTag capacity, and the Asia designation. Software present on a computer is not a license record; the installed version and the owned entitlement are separate facts that usually agree but must both be read. If the records disagree, resolve the discrepancy with Siemens or your authorized distributor before placing an order, because every later step compares against this record.

Keep the product-family match explicit. A catalog item whose title contains WinCC is not automatically an upgrade for Runtime Professional; match the product named in the upgrade description against the product on your certificate.

Field one: the target WinCC version #

Read both ends of the transition in the catalog description: the versions that qualify and the version the upgrade produces. A real documented entry shows the shape: order number 6AV2103-3XA02-3AK5 is WinCC Professional V19 at the maximum PowerTag class, floating license, engineering in the TIA Portal, and its upgrade path reads V11..V18 -> V19, with V11..V18 combo -> V19 combo for combined licenses. A line like that takes a V13 runtime straight to V19 in one step, with no intermediate upgrades to buy.

A destination-version match alone is not the whole eligibility check. If a description leaves the qualifying existing versions unclear, get confirmation against your actual license instead of accepting an item because its title mentions the release you want. Separately, check the target version's installation requirements and project migration path in the Siemens documentation; a correct entitlement cannot fix an unsupported operating system.

Field two: the PowerTag count of the existing license #

PowerTags are the tags used for communication between the controller and the HMI, and their licensed count is what distinguishes the runtime license sizes. For the upgrade selection, the number that matters is the capacity on the existing entitlement, not the number of tags your project happens to use today. A project that communicates fewer tags than the license allows still sits on the larger entitlement, and the upgrade must match that larger capacity.

Read the resulting entitlement on the selected line rather than assuming a version upgrade raises capacity. If the migrated project will need more PowerTags than the existing license allows, that is a separate capacity-sizing step decided by counting the tags that actually communicate with the controller.

Field three: delivery form #

The listed alternatives are download and DVD plus USB stick. Delivery form describes how the item is supplied; it is not the Asia-versus-standard distinction. Check the delivery field on the exact order line, because some upgrade lines are downloadable only. For a runtime computer on an isolated network, order a line that lists DVD plus USB stick, or plan the documented transfer of the downloaded package and license key from a connected machine.

Searching the Industry Mall without hiding the upgrades #

Set the version filter to anything except WinCC ASIA. With that setting selected, the upgrade entries are not listed, and an empty result does not mean an Asia license has no upgrade path; it means the filter excluded the shared entries. The runtime software upgrade entries are presented as version-independent upgrades in the mall's version selector, which is exactly why a version filter works against you. Clear it, then narrow the results by the target WinCC version and the PowerTag count you recorded. If the catalog search is blocked before it begins, a walkthrough of the TIA Selection Tool Industry Mall access login fix gets you past the sign-in problem.

Worked example: a V17 line moved to V19 #

Take an example plant with Runtime Professional V17, Asia, whose certificate states 2,048 PowerTags (an example value), and a project that communicates 1,940 PowerTags (an example count), moving to V19.

Version: 17 lies inside the documented V11..V18 -> V19 range, so that line qualifies and no intermediate step is needed.

Capacity: headroom is 2,048 minus 1,940, which is 108 PowerTags. The migration adds no new communicating tags in this example, so the upgrade line for the same existing capacity class is sufficient. Had the migration added 200 communicating tags, the need would be 1,940 plus 200, which is 2,140 and exceeds the licensed 2,048, so a capacity step-up would be ordered as its own decision alongside the version upgrade.

Delivery: the runtime PC is on an isolated network, so choose the order line that lists DVD plus USB stick.

Result: one order line, matched on target version, existing PowerTag capacity and delivery form, with no Asia-specific variant anywhere in the selection.

Before you place the order #

Check the order line itself, not the search-result heading. Confirm the target version against your deployment plan, the qualifying capacity against your certificate, and the delivery field against your procurement needs. Missing Asia wording is not a reason to reject a line, and finding a line through a broad WinCC search is not a reason to accept one. After delivery, install per the target version's documented requirements and run the migrated project on a bench before the production machine depends on it: never commission an upgraded runtime for the first time on a live machine.

Questions asked

Does the upgrade order include the installation software for the new version?

The delivery form decides how the software arrives: a download supplies the installation package electronically, and DVD plus USB stick supplies physical media. The entitlement and the installation remain separate checks. The target version's documented installation requirements and project migration steps still apply, and the runtime only runs licensed once the delivered key is installed.

My existing license is a combo of runtime and engineering. Do I order two upgrades?

No. The same catalog entry covers both cases: it is documented as an upgrade V11 up to V18 to V19 for the runtime, and as a combo upgrade V11 up to V18 to V19 combo for a combined runtime-plus-engineering license. One order line upgrades the whole combo, with engineering carried out in the TIA Portal.

Do tags that only calculate inside the runtime count against the PowerTag count?

PowerTags are the tags used for communication between the controller and the HMI. A tag that exists only inside the runtime, for calculations or screen logic without a controller connection, does not communicate and therefore does not consume PowerTag capacity. When sizing, count the tags that actually exchange data with the controller, not the total tag database.

The runtime PC is air-gapped. Which delivery form should I order?

Order a line that lists DVD plus USB stick as its delivery form, because some upgrade lines on the Industry Mall are downloadable only and will not help an offline machine. Check the delivery field on the exact order line before purchasing. If only the download form is available for the line you need, download it on a connected office machine and move the package and license key to the runtime PC using the documented license transfer procedure.

Keep reading

  • Troubleshooting

    Why WinCC Professional Images Turn White in Runtime

    Images that keep their color in the editor but turn white in WinCC Runtime and Simulation, and images that break after the project moves to another path, are both symptoms of a stale or external image-resource association inside the project. Reimport each failing image through the project's own graphics management, then verify it in the editor, Simulation, Runtime and after relocation.

    HMI and touchscreens

  • Explainer

    Does a WinCC Professional entry mean SCADA runtime is installed

    No. The WinCC Professional line in the TIA Portal version information names the engineering product only. WinCC Runtime Professional is a separate installation with its own license, sized in capacity tiers rather than per-tag fees, so check the installed product list and Automation License Manager entries before you build the project.

    HMI and touchscreens

  • Explainer

    Why a Comfort Panel shows only VB scripts, not C scripts

    There is no setting to enable C scripts on a Comfort Panel. The configured target decides: a Comfort Panel supports VB scripts only, while C scripts execute in WinCC Runtime Professional, the PC-based SCADA runtime. If C-script logic is required, run that part on a Professional Runtime PC target or rewrite it in VB for the panel.