IMDTouchKnowledge BaseShop main store

Explainer

Developing SINUMERIK Operate custom screens with Qt

HMI and touchscreens Published 5 min read By IMDTouch engineering team

Short answer

Custom SINUMERIK Operate screens are developed with Qt/C++ through the documented package SINUMERIK Integrate Create MyHMI /3GL, which you match to your exact installed Operate release. Visual Studio C++ 2008 on an 840D sl is one historical toolchain, not a universal requirement. Compile success is not acceptance: prove host loading and NCU/PLC data access separately.

On this page
  1. What the package gives you
  2. The toolchain is version-bound, not universal
  3. Build order that keeps failures narrow
  4. Acceptance: prove loading and data separately
  5. Stand-alone operation is its own project
  6. Questions asked

Yes — custom screens for SINUMERIK Operate are a documented Qt/C++ development path, and the package that defines it is SINUMERIK Integrate Create MyHMI /3GL. Siemens describes it as the toolset for creating HMI extensions to the Operate user interface, and the same framework can also build stand-alone user interfaces for SINUMERIK 840D sl and SINUMERIK ONE. The decision is not "Qt or no Qt"; it is which package edition matches your installed Operate release, and which execution model your screen needs.

What the package gives you #

SINUMERIK Integrate Create MyHMI /3GL ships the Qt API documentation, project templates and installation instructions for HMI extensions. Inside Operate, the HMI communicates with the NCK, PLC and drives through a documented softbus interface, and an extension built with this package uses that same path to read machine data and trigger machine functions. The package documentation also covers auxiliary components such as the X3D Viewer for animated and non-animated graphical scenes.

Obtain the package, its manuals and any license entitlements only through Siemens' support portal or an authorized distributor — for example, the technical documentation entry for SINUMERIK Integrate Create MyHMI /3GL (Siemens document ID 109963364) and the installation manual (ID 109955129). Do not pull libraries or headers from a code repository and assume they match your release.

The toolchain is version-bound, not universal #

A developer working with 840D sl reported building customized screens under Qt with Microsoft Visual Studio C++ 2008. Treat that as one historical data point: it shows the route was used, not that your installation needs that compiler. The supported compiler, Qt release and target architecture come from the Create MyHMI /3GL documentation for your exact installed Operate release. Read that combination out of the manual before you create the project; do not upgrade the compiler "because it should be compatible" and do not reuse an old project file unchanged.

Licensing is a separate boundary. Permission to develop, to distribute and to deploy an application are distinct rights, and Siemens and Qt license terms both apply to the deployment model you choose. Sort that out before the first machine deployment, not after.

Build order that keeps failures narrow #

  1. Record the target: controller model, installed Operate release, and HMI host platform, from the control's identification and software information displays. The controller family alone is not enough to pick a build environment.
  2. Decide the execution model: an extension inside Operate, or a stand-alone application. These are different architectures with different supported interfaces.
  3. Install the package edition that matches the release recorded in step 1, and confirm its compiler and Qt requirements.
  4. Build and deploy the package's sample project unchanged, using the quick-start that generates a new HMI project and integrates it into Operate (Siemens quick-entry document ID 109955234). This proves your toolchain and host before any of your own code exists.
  5. Add a minimal custom view: open, close and navigate away from it cleanly.
  6. Add one documented, read-only machine value before any subscription sets or machine commands.

Keep the first deployment that small. When interface customization, data access and machine commands all arrive at once, a host-loading fault looks identical to a communication fault.

Acceptance: prove loading and data separately #

A compiled screen that displays a plausible number is not an accepted screen. Split the checks:

  • Host loading — open the screen through its intended Operate entry point; it must appear without loader or missing-library errors and normal HMI navigation must keep working. Leave and reopen it, then restart the HMI once under controlled conditions: no duplicate views, no lost registration.
  • Data identity — compare your read-only value against an existing Operate display for the same quantity: same address, same units, understood scaling.
  • Data freshness — observe a real change in the quantity; your display must follow it, and an interrupted connection must show a recognizable unavailable state, never a stale but plausible reading.

Worked example, on the bench with the drive enabled through the machine's normal safety chain: pick one axis position as the test quantity. Jog the axis 10.000 mm from its current position; the extension must track the move within one HMI update cycle and settle at a reading exactly 10.000 mm from the start value. Then open the machine's own position display beside your screen and confirm both show the same value in millimeters at rest. If the value is off by a fixed factor, suspect scaling in your subscription; if it is stale, suspect the data path, not the layout.

If loading fails, inspect build configuration and host diagnostics first. If loading succeeds but data is missing or wrong, inspect the requested quantity and data interface before rebuilding the UI.

Stand-alone operation is its own project #

An application that must talk to the NCU and PLC without Operate running is a different architecture, and Siemens supports it separately. The softbus path an embedded extension uses belongs to the running Operate host; a stand-alone application needs the independent communication route documented for your controller, with its own runtime dependencies and license terms. A working embedded screen proves nothing about the stand-alone case — qualify them as separate builds with separate acceptance tests.

For the WinCC side of SINUMERIK integration — why WinCC Runtime Advanced joins Operate rather than replacing it — see why-wincc-joins-sinumerik-operate-instead-of-replacing-it, and for picking the HMI programming package by 840D sl software version, see which-hmi-programming-package-an-840d-sl-needs-by-software-version.

One safety note: development and acceptance work with machine commands belongs on a bench or a machine secured by its normal safety chain — light curtains, guards and e-stop circuitry intact and proved. Never validate a command function on a machine in production, and never bypass a safety device to make testing easier.

If your goal is a PC-based operator station rather than an extension of the machine's own HMI, the deployment target changes too: that is the territory of what-running-an-hmi-project-runtime-on-a-pc-without-the-panel-takes, and the hardware question becomes one of industrial panel PCs rather than Operate extensions.

Questions asked

Can I build custom screens for SINUMERIK Operate in Qt and C++?

Yes. Siemens documents the route in the SINUMERIK Integrate Create MyHMI /3GL package: you create HMI extensions to the Operate user interface as Qt/C++ projects, and the same framework can also build stand-alone interfaces for SINUMERIK 840D sl and SINUMERIK ONE. Get the package and its manuals through Siemens' support portal or a distributor, matched to your installed Operate release.

Do I have to use Visual Studio C++ 2008 for an 840D sl project?

No. Visual C++ 2008 is one toolchain a developer reported using with 840D sl, not a published requirement. The compiler and Qt release you need depend on your installed Operate release, so read the supported build environment in the Create MyHMI /3GL documentation for your version before starting a project. Never assume a newer compiler is safe.

My Qt project compiles but the screen never opens in Operate. What now?

A clean compile proves nothing about the host. The extension must match the Operate installation's ABI, Qt libraries and architecture, and must be deployed and registered by the package's documented procedure. First build and load the package's sample project unchanged; if that loads and yours does not, compare project configuration against the documented baseline before touching anything else.

Can my application talk to the NCU and PLC without Operate running?

That is a different, separately supported architecture. Inside Operate, extensions reach the NCK, PLC and drives through the documented softbus interface. An application that must run independently needs the supported stand-alone communication route for your controller, and success of an embedded screen proves nothing about it. Qualify the two cases as separate projects.

Keep reading

  • Comparison

    Which HMI programming package an 840D sl needs by software version

    The 840D sl's controller software version picks the toolchain. On SW 2.x, the existing 6FC5253-7BX20-6AG0 HMI Programming Package and your HMI Advanced applications carry over with minor adaptations. On SW 4.x the operator interface is Sinumerik Operate, applications must be rewritten with Create MyHMI/3GL (6FC5861-1YC41-1YA0, version 4.5 SP1) in .NET or C++ with Qt, and a different HMI OA option must be activated on the control.

    HMI and touchscreens

  • Explainer

    Why WinCC joins SINUMERIK Operate instead of replacing it

    WinCC Runtime Advanced does not replace SINUMERIK Operate on a PCU-based 840D sl. It is integrated into Operate and opened from a configured softkey, so the standard screens stay available while you build the machine-specific screens in WinCC. The option required is 6FC5800-0AP61-0YB0 once per NCU; the SIMATIC-panel option in the proposal belongs to a different architecture.

    HMI and touchscreens

  • Troubleshooting

    Why WinCC Runtime Advanced opens windowed under Operate

    When the runtime is full screen started by hand but windowed when Operate launches it, the project and installation are proven good and the fault is in the Operate integration. With oemframe set, Operate owns the window frame: audit the process registration, the area mapping, the panel type and resolution match, and the Integrate Create MyHMI/WinCC version pairing, and keep the shipped WindowsStyle_Off default.

    HMI and touchscreens

Why You Cannot Set a Custom PanelView 5310 Screen Saver Image