Why a WinCC Comfort Combo license is only reachable by upgrade
Short answer
A WinCC Comfort or Advanced Combo license exists only as the upgrade of a qualifying WinCC flexible 2008 engineering license: Compact or Standard 2008 to Comfort Combo, Advanced 2008 to Advanced Combo. A plain Comfort or Advanced license cannot be converted, so that workstation adds a separate flexible 2008 engineering license instead. Professional Combo is reached from either Combo by PowerPacks, one edition at a time.

On this page
A WinCC Comfort Combo or WinCC Advanced Combo license is not a standalone order item, and no product converts a plain Comfort or Advanced license into one. Outside the SIMATIC Field PG delivery scope, it exists in exactly one way: as the upgrade of a qualifying WinCC flexible 2008 engineering license. The TIA Portal licensing documentation lists three such paths, and a Professional Combo is then reached with PowerPack licenses, one edition at a time. What follows is the coverage, the three paths, and the order to write for each workstation.
What a Combo license covers #
A Combo license is an engineering license covering two products at once: a WinCC package inside TIA Portal and its predecessor product from before TIA Portal. Two WinCC Combo packages exist:
| Combo package | TIA Portal engineering included | Predecessor engineering included |
|---|---|---|
| WinCC Comfort V1x Combo | WinCC Comfort V1x | WinCC flexible 2008 Standard |
| WinCC Advanced V1x Combo | WinCC Advanced V1x | WinCC flexible 2008 Advanced |
V1x is the licensing notation for the TIA Portal version family; the order and the license key name the concrete version. Comfort, Advanced and Professional are the ascending editions of WinCC engineering inside TIA Portal, and how WinCC Explorer, Advanced, Professional, Flexible and Unified differ places each of them.
Engineering entitlement builds projects; running them is licensed by the runtime product, the same line drawn in whether a WinCC Professional entry means a SCADA runtime is installed. A Combo adds no runtime.
The three documented upgrade paths #
The paths come from the Licensing STEP 7 and WinCC section of the TIA Portal installation documentation, which is the reference for everything below:
| Qualifying starting license | Upgrade destination |
|---|---|
| WinCC flexible Compact 2008 | WinCC Comfort V1x Combo |
| WinCC flexible Standard 2008 | WinCC Comfort V1x Combo |
| WinCC flexible Advanced 2008 | WinCC Advanced V1x Combo |
The Compact row holds the one trap. Its destination is the Comfort Combo, whose documented predecessor coverage is WinCC flexible 2008 Standard. The starting edition and the coverage of the resulting package are separate facts, so read the entitlement the Combo grants instead of carrying the starting edition forward.
Why there is no direct order and no conversion #
Directly orderable Combos do exist elsewhere in TIA Portal, for example for STEP 7 Professional or Safety Advanced, and that is why buyers expect one for WinCC. For WinCC there is none: the only delivery outside the upgrade process is the Combo included with a SIMATIC Field PG, and that inclusion belongs to the notebook purchase, so it opens no ordering route for an ordinary office workstation.
The conversion is the second dead end. Every Combo upgrade names a WinCC flexible 2008 license as its starting product. A plain WinCC Comfort V1x or WinCC Advanced V1x license is not the starting product of any of the three paths, so no upgrade and no PowerPack turns it into a Combo.
The documented answer for such a workstation is coexistence: keep the existing TIA Portal license and add a separate WinCC flexible 2008 engineering license in the edition the legacy projects need. Two licenses deliver both platform entitlements without Combo status. Record exactly that in the license inventory, so a later edition plan does not build on a Combo that does not exist.
Worked example: the order for a Professional Combo seat #
A new engineering seat must maintain WinCC flexible 2008 Advanced panels and also engineer a WinCC Professional project at the current TIA Portal version. The order:
- 1 × WinCC flexible Advanced 2008, the qualifying predecessor
- 1 × the upgrade from WinCC flexible Advanced 2008 to WinCC Advanced V1x Combo
- 1 × the PowerPack from WinCC Advanced to WinCC Professional, in the same TIA Portal version
The arithmetic: 1 predecessor + 1 upgrade = 1 Advanced Combo license, and 1 Advanced Combo + 1 PowerPack = 1 Professional Combo. The order carries 3 positions.
Run the same target through the Comfort side and the count grows: 1 predecessor + 1 upgrade to Comfort Combo + 2 PowerPacks, Comfort to Advanced and then Advanced to Professional, = 4 positions. When the target is Professional and the legacy work is Advanced panels, the Advanced route saves one PowerPack.
The contrast case is the existing workstation with a plain WinCC Comfort V1x license that must keep engineering flexible 2008 Standard panels. No conversion exists, so the order is 1 position, a separate WinCC flexible 2008 engineering license, and the seat ends with two coexisting licenses.
PowerPacks move one edition at a time #
A PowerPack changes a license from a smaller TIA Portal edition to a larger one inside the same TIA Portal version. Two rules follow from that definition. Edition steps are taken singly, Comfort to Advanced and then Advanced to Professional, so no PowerPack skips an edition. And a PowerPack never changes the version, because version is the other axis: a license covers its own version and earlier versions of the same edition, which is why a WinCC Comfort V15 license covers TIA Portal V14, while a newer version than the license names needs a version upgrade, a different product from a PowerPack.
Keep both platforms or migrate the old projects #
A Combo pays its way only while both platforms must stay engineerable. If the flexible 2008 projects will move into TIA Portal and stay there, the seat needs no Combo: the plain Comfort or Advanced license engineers the migrated projects. Version capability decides whether that migration runs directly, and WinCC V11 SP2, for example, migrates WinCC flexible 2008 SP3 projects directly once its Update 3 is installed. The background on the old platform's lifetime and its runtime licensing is in the WinCC flexible 2008 lifecycle and the Runtime Advanced license.
The decision for each workstation #
- New seat engineering Comfort with legacy Standard or Compact panels: order the qualifying flexible 2008 license and the Comfort Combo upgrade, 2 positions.
- New seat engineering Advanced with legacy Advanced panels: WinCC flexible Advanced 2008 and the Advanced Combo upgrade, 2 positions.
- New seat with a Professional Combo target: go through Advanced, 3 positions against 4 through Comfort.
- Existing plain Comfort or Advanced seat with a legacy requirement: no conversion exists, so add one separate flexible 2008 engineering license, 1 position, two coexisting licenses, no Combo status.
- Any seat with no flexible 2008 work at all: buy no Combo and no flexible license.
Before any PowerPack is applied, read the workstation's license display: the designation must show the intended Combo package and edition. Keep the purchase and upgrade records together, because that record is what every later edition step and every license audit reads. Order numbers and current availability come from Siemens' ordering information at purchase time; the paths above are the structure that information fills.
Questions asked
Does a Comfort or Advanced Combo license include a runtime for the panels or PCs?
No. A Combo license is engineering only: it builds projects, it does not run them. Comfort Panels execute their projects on the runtime embedded in the device, so they need no separate runtime key, while a PC station needs its own runtime product, such as WinCC Runtime Advanced, matched to the runtime version the project was configured for.
Do PowerPacks also raise the power tag count of a Professional license?
No. The PowerPacks described here change the edition: Comfort to Advanced, Advanced to Professional, always inside one TIA Portal version. The number of power tags a Professional project may use is raised by separate capacity PowerPacks, so a project that outgrows its licensed tag count buys a capacity step, never another edition step.
Can the Combo upgrade be bought and installed without the flexible license?
No. The upgrade applies only to a workstation whose license records show the qualifying flexible 2008 license, so a new seat buys the predecessor and the upgrade together in one order. An upgrade key on its own finds no license to build on and creates no Combo entitlement.
Is there a Combo package for WinCC Basic as well?
The licensing documentation lists Combo packages for Comfort and Advanced only, with Professional reached from them by PowerPack, and no Basic Combo appears in its upgrade list. A Basic workstation therefore keeps its plain license, and legacy flexible engineering on that seat is covered by a separate flexible license, never by a Combo.